White Rodgers Cooling Controls 50D50U-843 Universal Intermittent Pilot All Spark 24V Ignition Module,White Rodgers 50D50U-843
Item#:
50D50U-843
Manufacturer Item:
50D50U-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50E47-843 Silicon Carbide Universal Non-Integrated Hot Surface Ignition Control Kit, 18 - 30 VAC, 0.2 amp
- Program keys for easy customization
- Tri-color LED indicator for diagnostics
- Direct and indirect flame sense
- Replaces all White Rodgers Cooling Controls 50E47-xxx modules and virtually all competitive silicon carbide, non-integrated modules
- 6 amp at 120 VAC, 60 Hz resistive igniter relay
- Includes program keys, mounting hardware, double-sided foam back tape (for ease of installation), extensive cross-reference guide, color-coded timing label, pre-printed hanging carTon, instructions in english/instructions en espanol
- 95% RH non-condensing humidity range
Item#:
50E47-843
Manufacturer Item:
50E47-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 5059-134 Pilot Relite Control, 24 VAC, 0.03 amp
- Generates spark pulse until flame is sensed through spark electrode
- Begins sparking immediately if flame extinguishes
- Rugged solid state module design
- Spike terminal high voltage and 1/4" spade terminals connection
Item#:
5059-134
Manufacturer Item:
5059-134
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50E70-820 HSI Integrated Furnace Control, 18 - 30 VAC, 60 Hz
- 1-stage applications
- 120 volt HSI ignition
- Adapter board and harness included
- For packaged units
- Flame current test pins
- Red and green status LEDs
- Standoffs/adapter board mounting
- 0.8 sec flame establishing time, 2 sec flame failure response time at 60 Hz
- Flame current requirements - minimum current to insure flame detection: 1 micro-amp DC, maximum current for non-detection: 0.1 micro-amp DC, maximum allowable leakage resistance: 100 mega-ohm,
Item#:
50E70-820
Manufacturer Item:
50E70-820
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50D50-842 Universal DSI Control for Gas-Fired Non-Integrated Forced Air Furnaces, Boilers, 25 VAC, 0.2 amp, 4.13" W x 4.13" H x 1-1/2" D
- Color LED indicator for diagnostics
- Includes program keys, double-sided foam back tape, color coded timing label, pre-printed hanging carTon
- 1/4 and 3/16" quick connect terminals
- Direct and indirect flame sense
Item#:
50D50-842
Manufacturer Item:
50D50-842
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56-743 Hot Surface Igniter Nitride Integrated Furnace Control, 25 VAC, 0.45 amp, 50/60 Hz
- System diagnostic LED with fault recall
- Multi speed circulator
- 1 or 2-stage gas valve
- Relay load ratings - 1.5 amp at 25 VAC 50/60 Hz 0.6 pico-F valve relay, 6 amp at 120 VAC 50/60 Hz (resistive) igniter relay, 2.2 amp full load, 3.5 amp locked rotor at 120 VAC inducer relay, 14.5 amp full load, 25 amp locked rotor at 120 VAC circulator relay
- Flame current requirements - 1 micro-amp DC minimum current to insure flame detection, 0.10 micro-amp DC maximum current for non-detection, 100 mega-ohm maximum allowable leakage resistance
- 0.8 sec flame establishing time, 2 sec flame failure response time
Item#:
50M56-743
Manufacturer Item:
50M56-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
The 50A66-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.
- 3-fan speeds
- Remote flame sensing
- Humidifier and electronic air cleaner connections (optional)
- 1.5 amp valve relay
- 6 amp igniter relay
- 2.2 amp full load - 3.5 amp locked rotor inducer relay
- 14.5 amp full load - 25 amp locked rotor circulator relay
- Diagnostic indicator flash codes, controls gas valve, igniter, blower, inducer, humidifier and air cleaner
Item#:
50A66-743
Manufacturer Item:
50A66-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50D50-801 Pilot Spark Ignition Control for Gas Appliance 18-30 VAC 0.2 amp
Item#:
50D50-801
Manufacturer Item:
30W33
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Peerless Boiler Parts 54156 System Sensor
Item#:
54156
Manufacturer Item:
54156
Manufacturer:
PB HEAT, LLC
Peerless Boiler Parts 54299 Supply Sensor
Item#:
54299
Manufacturer Item:
54299
Manufacturer:
PB HEAT, LLC
Peerless Boiler Parts 51769 Steam Gauge WBV/EC/ECT
Item#:
51769
Manufacturer Item:
51769
Manufacturer:
PB HEAT, LLC
Peerless Boiler Parts 51670 Casting Gasket 211A
Item#:
51670
Manufacturer Item:
51670
Manufacturer:
PB HEAT, LLC