Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor

Sid Harvey Remanufactured C317-8R

Item#:
C317-8R
Manufacturer Item:
L8124G1020
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C312-10R High Limit Aquastat Relay, 100 - 240 deg F
Sid Harvey Item #:C312-10R: Replaces Part #:'s : 0R258,
,

Sid Harvey Remanufactured C312-10R

Item#:
C312-10R
Manufacturer Item:
C312-10
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290R Aquastat, 100 - 240 deg F, 5 - 30 deg F Mid-ScaleSid Harvey Item #:C290R: Replaces Part #:'s : AQU4006A1678-C290 | AQU4006A2007-C290A | C290 | C290A |,
,

Sid Harvey Remanufactured C290R

Item#:
C290R
Manufacturer Item:
L4006A1678-2007
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D
  • Pressure actuated high limit, safety control for steam heating boilers, It breaks an electrical circuit to shut down the burner if steam pressure rises above a safe level
  • Contains an SPST Micro switch snap-acting switch
  • Sensitive pressure actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism which operates the snap switch
  • A screw on top of the case allows setpoint adjustment without removing the cover
  • Differential is adjusted by means of a dial located inside the case
  • Recommended minimum setpoint is differential setting plus 1-1/2 psi
  • Stainless steel diaphragm sensor element
  • Makes at setpoint on pressure fall breaks at setpoint plus differential on pressure rise Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D,

    Sid Harvey Remanufactured C354R

Item#:
C354R
Manufacturer Item:
PA404A1033
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C434-9R Fan Limit Control, Remanufactured
  • ,
    ,

    Sid Harvey Remanufactured C434-9R

Item#:
C434-9R
Manufacturer Item:
C434-9
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
  • Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
  • High limit opens burner circuit only
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • 1-1/2 - 3 Inch depth less well insulation
  • Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
  • Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential,
    ,

    Sid Harvey Remanufactured C312-9R

Item#:
C312-9R
Manufacturer Item:
L8148J1009
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-7R Fan limit Control 5'' REMANUFACTURED,
,

Sid Harvey Remanufactured C434-7R

Item#:
C434-7R
Manufacturer Item:
C434-7R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C293-3R Aquastat Immersion SPDT 100-240 Degrees REMANUFACTURED,
,

Sid Harvey Remanufactured C293-3R

Item#:
C293-3R
Manufacturer Item:
L6006A1145
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C322-4R Dual Aquastat, 130 - 240 deg F High Limit, 110 - 220Sid Harvey Item #:C322-4R: Replaces Part #:'s : C322-4A,
,

Sid Harvey Remanufactured C322-4R

Item#:
C322-4R
Manufacturer Item:
L4081B1096-1047
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124A High and Low Limit Circulator Triple Aquastat Relay, 120 VAC, 130 - 240 deg F Adjustable High Limit, 110 - 220 deg F Adjustable Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-2R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317R,
,

Sid Harvey Remanufactured C317-2R

Item#:
C317-2R
Manufacturer Item:
L8124A1007,1015,1098
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured A28-69R Motor 1/3 HP 115 VAC 1725 RPM CW W/Bracket REMANUFACTURED

Sid Harvey Remanufactured A28-69R

Item#:
A28-69R
Manufacturer Item:
131-143RP
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Mcdonnell & Miller 67 Mechanical Low Water Cut-Off, 120/240 VAC, 20 psi, Automatic Reset
  • Quick hook-up fittings provided
  • Lever operated, full port ball valve for easy blow down
  • Adjustable Bx outlet for easy installation
  • Dual precision switches for dependable operation of cut-off, alarm or electric water feeder Mcdonnell & Miller 67 Mechanical Low Water Cut-Off, 120/240 VAC, 20 psi, Automatic Reset,
    ,

    Sid Harvey Remanufactured B103R

Item#:
B103R
Manufacturer Item:
67
Manufacturer:
SID HARVEY REMANUFACTURED