Sid Harvey L7224U oil electronic Aquastat controller provides electronic temperature sensing in a UL limit-rated controller, controls the circulator, oil burner and boiler temperature, and provides status, LED diagnostic and Eircom communication.
  • Envigado, a low-cost 3-wire communication protocol that allows different devices, such as communicating thermostats, Aquastat and oil primaries, to connect and share information Honeywell L7224U1002 Electronic Oil Aquastat, 120 VAC, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit , 5 - 20 deg F Fixed High Limit, 10 - 25 deg F Adjustable Low Limit Differential

    Sid Harvey Remanufactured C317-14R

Item#:
C317-14R
Manufacturer Item:
L7224U1002
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
    Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor


C317-8R

Item#:
C317-8R
Manufacturer Item:
L8124G1020
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290R Aquastat, 100 - 240 deg F, 5 - 30 deg F Mid-Scale Sid Harvey Item #:C290R: Replaces Part #:'s : AQU4006A1678-C290 | AQU4006A2007-C290A | C290 | C290A |,

C290R

Item#:
C290R
Manufacturer Item:
L4006A1678-2007
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C354-1R Pressuretrol Controller, SPST, 0.5-9 psi Adjustable, 3-3/8" W x 4-15/32" H x 2-1/4" D, Remanufactured
  • The PA404 is a series 40 (2-wire, SPST) Pressuretrol controller for use in 24, 120, 240 or 277 volt control circuits or in self powered (millivoltage) applications
  • The PA404B is used with suspension-type unit heaters to make the fan circuit when a pressure rise indicates the presence of steam
  • Each model contains an SPST micro-switch snap-acting switch
  • Sensitive pressure-actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism which operates the snap switch
  • A screw on top of the case allows set point adjustment without removing the cover
  • Differential is adjusted by means of a dial located inside the case
  • Recommended minimum set point is differential setting plus 1-1/2 psi
  • Tradeline value
  • Stainless steel diaphragm sensor element
  • Additive or subtractive differential type
  • Makes at set point plus differential on pressure rise, breaks at set point on pressure fall
  • 50 psi pressure surge
  • 0.5-9 psi adjustable scale range,

    C354-1R

Item#:
C354-1R
Manufacturer Item:
PA404B1023
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C322-4R Dual Aquastat, 130 - 240 deg F High Limit, 110 - 220

C322-4R

Item#:
C322-4R
Manufacturer Item:
L4081B1096-1047
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-12R Fan limit Control 8'' REMANUFACTURED,

C434-12R

Item#:
C434-12R
Manufacturer Item:
C434-12R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey High Limit Aquastat Relay 8F differential REMANUFACTURED. Immersion type controllers that combine high limit protection with switching relay control of burner and circulator motors
    High limit opens burner circuit only.
  • Includes transformer and accessory terminals for adding a remote low limit controller.
  • Case available for horizontal or vertical mounting.
  • Requires a 24 VAC thermostat with heat anticipator set at 0.2 amps.

    C312-8R

Item#:
C312-8R
Manufacturer Item:
L8148A1017
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290-1R Bronze Close On Rise Aquastat, 100 - 240 deg F, Remanufactured
  • 3" insulation, stop factory set at 240 deg F, well adapter and heat conductive compound includes,

    C290-1R

Item#:
C290-1R
Manufacturer Item:
L4006B1155-1163
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C312-10R High Limit Aquastat Relay, 100 - 240 deg F1>

C312-10R

Item#:
C312-10R
Manufacturer Item:
C312-10
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D
  • Pressure actuated high limit, safety control for steam heating boilers, It breaks an electrical circuit to shut down the burner if steam pressure rises above a safe level
  • Contains an SPST Micro switch snap-acting switch
  • Sensitive pressure actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism which operates the snap switch
  • A screw on top of the case allows setpoint adjustment without removing the cover
  • Differential is adjusted by means of a dial located inside the case
  • Recommended minimum setpoint is differential setting plus 1-1/2 psi
  • Stainless steel diaphragm sensor element
  • Makes at setpoint on pressure fall breaks at setpoint plus differential on pressure rise Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D,

    C354R

Item#:
C354R
Manufacturer Item:
PA404A1033
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C434-9R Fan Limit Control, Remanufactured
  • ,

    C434-9R

Item#:
C434-9R
Manufacturer Item:
C434-9
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
  • Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
  • High limit opens burner circuit only
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • 1-1/2 - 3 Inch depth less well insulation
  • Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
  • Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential,

    C312-9R