S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Remanufactured products are available only with exchange for similar defective units. All products will be assessed a CORE Charge until exchange is completed.
What is a core Charge?
- CORE Charges vary by product.
- All Remanufactured items purchased will be assessed a CORE CHARGE at invoice based on product.
- CORE CHARGES will be refunded when CORES are dropped off at store location or pickup arrangements are pre-arranged.
- Bulk CORE pickups must be coordinated with local store managers or Sid Harvey Corporate Office.
Triatomic Environmental TUV-APCOX-DER3 UV Air Purifier System 18-32 VAC V-Twin Carbon Duct Mounted
Triatomic Environmental TUV-APCOX-DER3
Item#:
TUV-APCOX-DER3
Manufacturer Item:
TUV-APCOX-DER3
Manufacturer:
TRIATOMIC ENVIRONMENTAL, INC.
Dust Free 13071 Active Air Purifier Active 12"
Dust Free 13071
Dust Free 13077 Replacement UV Lamp 12"
Dust Free 13077
Sid Harvey Honeywell L8124C High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
,
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
,
Sid Harvey Remanufactured C317-5R
Item#:
C317-5R
Manufacturer Item:
L8124C1003
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124L High Limit Triple Aquastat Relay, 24 - 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
,
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
,
Sid Harvey Remanufactured C317-11R
Item#:
C317-11R
Manufacturer Item:
L8124L1011
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124E High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
Mount directly to boiler - Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Remanufactured C317-7R
Item#:
C317-7R
Manufacturer Item:
L8124E1016
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey L8151A is a remote bulb controller for use with hydronic heating systems that include domestic hot water service.
,
- Provides high limit, low limit and circulator control for maintaining boiler temperatures
- Can provide multizone control by using a separate thermostat and R845 Relay for each zone
- An internal transformer powers the thermostat circuit
- Shielded capillary allows convenient mounting
- Consists of a diaphragm powerhead and micro switch assembly that responds to temperature changes in the boiler water
- Mounting lugs on back of case
,
Sid Harvey Remanufactured C317-13R
Item#:
C317-13R
Manufacturer Item:
L8151A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-12R Fan limit Control 8'' REMANUFACTURED,
,
,
Sid Harvey Remanufactured C434-12R
Item#:
C434-12R
Manufacturer Item:
C434-12R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C317R Triple Aquastat, 110 - 220 deg F Low Limit, 130 - 240 deg F High Limit, 10 - 25 deg F Adjustable Low Limit, 10 deg F Fixed High Limit Differential, SPST, 120 VAC, Remanufactured
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water
- Provides multi zone control by using a separate circulator and relay for each zone
- Includes diaphragm power head and Micro-Switch assembly that respond to temperature changes in boiler water
- Mounts directly to boiler
- Requires a 24 VAC thermostat with heat anticipator set at 0.2 ampSid Harvey Item #:C317R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317-2R,
,
Sid Harvey Remanufactured C317R
Item#:
C317R
Manufacturer Item:
L8024A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey L7224U oil electronic aquastat controller provides electronic temperature sensing in a UL limit-rated controller, controls the circulator, oil burner and boiler temperature, and provides status, LED diagnostic and EnviroCOM communication.
- EnviraCOM, a low-cost 3-wire communication protocol that allows different devices, such as communicating thermostats, aquastats and oil primaries, to connect and share information Honeywell L7224U1002 Electronic Oil Aquastat, 120 VAC, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit , 5 - 20 deg F Fixed High Limit, 10 - 25 deg F Adjustable Low Limit Differential,
,
Sid Harvey Remanufactured C317-14R
Item#:
C317-14R
Manufacturer Item:
L7224U1002
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey High Limit Aquastat Relay 8F differential REMANUFACTURED. Immersion type controllers that combine high limit protection with switchingrelay control of burner and circulator motors
,
- High limit opens burner circuit only.
- Includes transformer and accessory terminals for adding a remote low limit controller.
- Case available for horizontal or vertical mounting.
- Requires a 24 VAC thermostat with heat anticipator set at 0.2 amps.
,
Sid Harvey Remanufactured C312-8R
Item#:
C312-8R
Manufacturer Item:
L8148A1017
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290-1R Bronze Close On Rise Aquastat, 100 - 240 deg F, Remanufactured
- 3" insulation, stop factory set at 240 deg F, well adapter and heat conductive compound includes,
,
Sid Harvey Remanufactured C290-1R
Item#:
C290-1R
Manufacturer Item:
L4006B1155-1163
Manufacturer:
SID HARVEY REMANUFACTURED