The Robertshaw 700 Series Combination Gas Valves offer replacement flexibility. With three-position outlets and multi-positional capability, these combination gas valves offer unlimited replacement possibilities. The 24 Volt Uni-Kit models are suitable for either natural or LP gas. The valve is factory set at 3.5" WC natural gas. A regulator cover plate is included to convert to LP gas.


Robertshaw G569-10

Item#:
G647-99
Manufacturer Item:
700-400
Manufacturer:
ROBERTSHAW CONTROLS CO.
Robertshaw Controls G566-60 Hot Surface Ignition Control Module 780-34NL306A,


Robertshaw G544-20

Item#:
G566-60
Manufacturer Item:
780-785
Manufacturer:
ROBERTSHAW CONTROLS CO.
The L62 series Baso safety shutoff devices are for use on all gas-fired, standing pilot equipment that requires main burner shutoff when the pilot is extinguished. Typical applications include domestic central heating and commercial space heating appliances, as well as industrial processing equipment (for example, die-casting machines and degreasers). Monitor the pilot flame through the use of a thermocouple. If the pilot flame is extinguished, the switch will interrupt gas flow to the main burner and pilot burner, shutting down the appliance.
  • The L62 has a manual reset feature, and is available in models with or without 100% shut-off
  • The L62 has a thermo-electric power unit assembly that receives its energy from a heated thermocouple
  • If the pilot flame is extinguished, the main valve circuit is interrupted and gas flow to the main burner (and pilot burner in 100% shut-off model L62GB) is stopped
  • Both L62 models contain an electric interruption feature that only allows pilot gas flow during the lighting or resetting cycle
  • When lighting the pilot, the main valve electrical circuit is interrupted until the pilot flame is established and the reset butTon is released
  • Allows only pilot gas flow during lighting cycle
  • 1 conduit opening
Sid Harvey Item #:G570: Replaces Part #:'s : 10700,

Igniter System G569-58

Item#:
G570
Manufacturer Item:
L62AA-5
Manufacturer:
JOHNSON CONTROLS, INC.
The Robertshaw 710 series low capacity gas valves feature an extremely compact control designed for low capacity and limited space applications. Features include 3-position outlets, multi-positional capability and component replaceability.


Robertshaw G665-1

Item#:
G665-1
Manufacturer Item:
710-502
Manufacturer:
ROBERTSHAW CONTROLS CO.
White Rodgers Cooling Controls 3046-5 Mercury Flame Sensor, 2-1/16" W x 2-3/4" H x 1-7/8" D
  • Contacts close approximately 60 sec after pilot is ignited, open approximately 40 sec after flame is extinguished
  • Prevent gas flow to main burner if pilot flame is not burning or is insufficient to properly ignite main burner
  • These sensors combine a rugged snap-action switch and powerful mercury actuated thermal element
  • Used with natural, manufactured or mixed gases and with LP gases where means are provided for obtaining automatic pilot gas shut-off
  • Switch may be conveniently mounted in any position
  • Cover is easily removed, making switch terminals readily accessible
  • No button to depress - sensors are recycling type which require relighting or possible restoration of proper gas pressure to return to operation
  • 90 VA at 30 VAC, 125 VA at 120 and 240 VAC electrical rating
Sid Harvey Item #:G581: Replaces Part #:'s : 24325,



White Rodgers G568-30

Item#:
G581
Manufacturer Item:
3046-5
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 30A46-5 Plug-In Mercury Flame Sensor, 120/240/30 VAC, 48" Element
  • Plug-in feature requires no additional electrical connections or mounting devices
  • Sensor combines a rugged snap-action SPDT switch and powerful mercury actuated thermal element
  • May be used with natural, manufactured or mixed gases and with LP gases where means are provided for obtaining automatic pilot gas shut-off
  • No button to depress sensors are recycling type which require relighting or possible restoration of proper gas pressure to return to operation
  • The SPDT switch can energize igniter circuit to relight pilot (as with roof top units)
  • Contacts close approximately 60 sec after pilot is ignited
  • Open approximately 40 sec after flame is extinguished
  • Stud mount element
Sid Harvey Item #:G588: Replaces Part #:'s : L36-134,



White Rodgers G588

Item#:
G588
Manufacturer Item:
30A46-5
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Baso Y9 series inlet fittings control the flow of gas to a pilot burner and are designed to be used with baso pilot burners. The majority of baso inlet fittings have two holes which control and direct the flow of gas to the burner. The gas flow from the two holes intersects. This unique feature causes turbulence and a better gas/air mixture for proper combustion.
  • Aluminum inlet tip, brass inlet body
  • 635 deg F inlet tip, 75 deg F inlet body
  • The Y9 inlet fitting controls the flow of gas to a pilot burner, the orifice hole size and counterbore/coining, along with the applied gas pressure, determine flame size and characteristics
  • Pilot burner inlet fittings consist of an inlet tip (containing the orifice holes) and a threaded inlet body allowing connection of the pilot line
  • The inlet fitting positions the orifice holes in relation to the pilot burners aeration opening and pilot tip
,
,



Baso G407-2

Item#:
G511-2
Manufacturer Item:
Y90AA-4210C
Manufacturer:
JOHNSON CONTROLS, INC.
Baso J999MKA-2 Universal 1-Stage Multi-Mount Shell Type Head Standing Pilot Burner for Ignition Systems


Baso G396-9

Item#:
G407
Manufacturer Item:
J999MKA-2H
Manufacturer:
JOHNSON CONTROLS, INC.
The Robertshaw 710 series low capacity gas valves feature an extremely compact control designed for low capacity and limited space applications. Features include 3-position outlets, multi-positional capability and component replaceability.
  • Extremely compact control designed for low capacity and limited space applications
  • Include 3-position outlets, multi-positional capability and component replaceability
  • Gas cock dial marking off-pilot-on
  • Standard NEMA terminals
  • Inlet filtered screen
  • Various gas types - natural, manufactured, mixed, LP and LP/air mixtures
  • 36" capillary length
  • (2) 1/2 x 3/8" NPT reducer bushing
  • Straight line regulation
  • Low capacity compact size
  • Outlet screen
  • Pressure taps for checking inlet and outlet gas pressure
  • Convenient 1/4 and 3/16" spade connector to prevent miss-wiring
  • Any angle between 0 and 90 deg from upright
  • pilot gas filters
  • Field upgradable
  • 2 cfh pilot capacity
Sid Harvey Item #:G665: Replaces Part #:'s : L37-525,
,



Robertshaw G664-32

Item#:
G665
Manufacturer Item:
710-205
Manufacturer:
ROBERTSHAW CONTROLS CO.
The Robertshaw 110 series water heating gas valves are designed for universal replacement applications in water tanks. All models feature a built-in, non-cycling energy cut-off (ECO) system to shut off all gas to the water heater in case of excessive water temperatures. The ECO is designed to detect over-temperature conditions and to open. Once opened, the control will not function and a new replacement will be required.
  • Domestic, commercial and recreational vehicle water heater thermostat uni-kits
  • Include 5-1/2" sensing element
  • Various inlet size, outlet size, regulator settings and shank lengths
  • Right hand threads
Sid Harvey Item #:G664-32: Replaces Part #:'s : AP-8555-B,



Robertshaw G664-22

Item#:
G664-32
Manufacturer Item:
110-202
Manufacturer:
ROBERTSHAW CONTROLS CO.
Honeywell VR8345 Direct Intermittent Pilot 1-Stage Compact Natural/LP Combination Gas Control Valve, 3/4"


Resideo G650-54

Item#:
G674-103
Manufacturer Item:
VR8345M4302
Manufacturer:
HONEYWELL
Baso L62GB-3C Manual Reset Pilot Switch, 8 amp at 125 VAC, 4 amp at 250 VAC


Baso G512-12

Item#:
G574-1
Manufacturer Item:
L62GB-3C
Manufacturer:
JOHNSON CONTROLS, INC.