|◀ 49 - 60 of 414 ▶|
View:
The Robertshaw 710 series low capacity gas valves feature an extremely compact control designed for low capacity and limited space applications. Features include 3-position outlets, multi-positional capability and component replaceability.

G665-1

Item#:
G665-1
Manufacturer Item:
710-502
Manufacturer:
ROBERTSHAW CONTROLS CO.
White Rodgers Cooling Controls 3046-5 Mercury Flame Sensor, 2-1/16" W x 2-3/4" H x 1-7/8" D
    Contacts close approximately 60 sec after pilot is ignited, open approximately 40 sec after flame is extinguished
  • Prevent gas flow to main burner if pilot flame is not burning or is insufficient to properly ignite main burner
  • These sensors combine a rugged snap-action switch and powerful mercury actuated thermal element
  • Used with natural, manufactured or mixed gases and with LP gases where means are provided for obtaining automatic pilot gas shut-off
  • Switch may be conveniently mounted in any position
  • Cover is easily removed, making switch terminals readily accessible
  • No button to depress - sensors are recycling type which require relighting or possible restoration of proper gas pressure to return to operation
  • 90 VA at 30 VAC, 125 VA at 120 and 240 VAC electrical rating

    G581

Item#:
G581
Manufacturer Item:
3046-5
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 30A46-5 Plug-In Mercury Flame Sensor, 120/240/30 VAC, 48" Element
    Plug-in feature requires no additional electrical connections or mounting devices
  • Sensor combines a rugged snap-action SPDT switch and powerful mercury actuated thermal element
  • May be used with natural, manufactured or mixed gases and with LP gases where means are provided for obtaining automatic pilot gas shut-off
  • No button to depress sensors are recycling type which require relighting or possible restoration of proper gas pressure to return to operation
  • The SPDT switch can energize igniter circuit to relight pilot (as with roof top units)
  • Contacts close approximately 60 sec after pilot is ignited
  • Open approximately 40 sec after flame is extinguished
  • Stud mount element

    White Rodgers G588

Item#:
G588
Manufacturer Item:
30A46-5
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Baso Y9 series inlet fittings control the flow of gas to a pilot burner and are designed to be used with baso pilot burners. The majority of baso inlet fittings have two holes which control and direct the flow of gas to the burner. The gas flow from the two holes intersects. This unique feature causes turbulence and a better gas/air mixture for proper combustion.
    Aluminum inlet tip, brass inlet body
  • 635 deg F inlet tip, 75 deg F inlet body
  • The Y9 inlet fitting controls the flow of gas to a pilot burner, the orifice hole size and counterbore/coining, along with the applied gas pressure, determine flame size and characteristics
  • Pilot burner inlet fittings consist of an inlet tip (containing the orifice holes) and a threaded inlet body allowing connection of the pilot line
  • The inlet fitting positions the orifice holes in relation to the pilot burners aeration opening and pilot tip

    G511-2

Item#:
G511-2
Manufacturer Item:
Y90AA-4210C
Manufacturer:
JOHNSON CONTROLS, INC.
Baso J999MKA-2 Universal 1-Stage Multi-Mount Shell Type Head Standing Pilot Burner for Ignition Systems

baso g407

Item#:
G407
Manufacturer Item:
J999MKA-2H
Manufacturer:
JOHNSON CONTROLS, INC.
The Robertshaw 710 series low capacity gas valves feature an extremely compact control designed for low capacity and limited space applications. Features include 3-position outlets, multi-positional capability and component replaceability.
    Extremely compact control designed for low capacity and limited space applications
  • Include 3-position outlets, multi-positional capability and component replaceability
  • Gas cock dial marking off-pilot-on
  • Standard NEMA terminals
  • Inlet filtered screen
  • Various gas types - natural, manufactured, mixed, LP and LP/air mixtures
  • 36" capillary length
  • (2) 1/2 x 3/8" NPT reducer bushing
  • Straight line regulation
  • Low capacity compact size
  • Outlet screen
  • Pressure taps for checking inlet and outlet gas pressure
  • Convenient 1/4 and 3/16" spade connector to prevent miss-wiring
  • Any angle between 0 and 90 deg from upright
  • pilot gas filters
  • Field upgradable
  • 2 cfh pilot capacity

    Robertshaw G665

Item#:
G665
Manufacturer Item:
710-205
Manufacturer:
ROBERTSHAW CONTROLS CO.
The Robertshaw 110 series water heating gas valves are designed for universal replacement applications in water tanks. All models feature a built-in, non-cycling energy cut-off (ECO) system to shut off all gas to the water heater in case of excessive water temperatures. The ECO is designed to detect over-temperature conditions and to open. Once opened, the control will not function and a new replacement will be required.
    Domestic, commercial and recreational vehicle water heater thermostat uni-kits
  • Include 5-1/2" sensing element
  • Various inlet size, outlet size, regulator settings and shank lengths
  • Right hand threads

    G664-32

Item#:
G664-32
Manufacturer Item:
110-202
Manufacturer:
ROBERTSHAW CONTROLS CO.
Honeywell VR8345 Direct Intermittent Pilot 1-Stage Compact Natural/LP Combination Gas Control Valve, 3/4"

honeywell g674-103

Item#:
G674-103
Manufacturer Item:
VR8345M4302
Manufacturer:
HONEYWELL
A vent limiting orifice or device when used with Maxitrol regulators does not release or relieve gas into the environment during normal operation. Vent limiters are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure is critical. Vent limiters should not be used outdoors if they are exposed to the environment. 13A15 Vent Protector is available for outdoor use when vent protection is required.
    For up to 1/2 psi (14" WC) inlet pressure
  • Note - when using the vent limiting device, regulator must be mounted in a horizontal upright position

    G1226-80

Item#:
G1226-80
Manufacturer Item:
12A04
Manufacturer:
MAXITROL COMPANY
A vent limiting orifice or device when used with Maxitrol regulators does not release or relieve gas into the environment during normal operation. Vent limiters are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure is critical. Vent limiters should not be used outdoors if they are exposed to the environment. 13A15 Vent Protector is available for outdoor use when vent protection is required

Maxitrol G1226-81

Item#:
G1226-81
Manufacturer Item:
12A09
Manufacturer:
MAXITROL COMPANY
A vent limiting orifice or device when used with Maxitrol regulators does not release or relieve gas into the environment during normal operation. Vent limiters are designed for use indoors and in spaces where limiting the amount of gas escapement due to diaphragm failure is critical. Vent limiters should not be used outdoors if they are exposed to the environment. 13A15 Vent Protector is available for outdoor use when vent protection is required

Maxitrol G1226-82

Item#:
G1226-82
Manufacturer Item:
12A39
Manufacturer:
MAXITROL COMPANY
Baso L62GB-3C Manual Reset Pilot Switch, 8 amp at 125 VAC, 4 amp at 250 VAC

baso g574-1

Item#:
G574-1
Manufacturer Item:
L62GB-3C
Manufacturer:
JOHNSON CONTROLS, INC.
|◀ 49 - 60 of 414 ▶|