|◀ 37 - 48 of 414 ▶|
View:
White Rodgers Cooling Controls 760-401 Tear Drop Mount Flame Sensor for Hot Surface Igniter, 30" Lead

White Rodgers G568-30

Item#:
G568-30
Manufacturer Item:
760-401
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 3098-156 Mercury Flame Sensor for Proving Pilot Flame and Controlling Main Valve in Cycle Pilot Applications, 48" Element

G567-62

Item#:
G567-62
Manufacturer Item:
3098-156
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Honeywell V88A1618/U Aluminum NC Diaphragm Natural/LP Gas Valve, 1", NPT
    Solenoid operated diaphragm valves provide slow opening and fast closing suitable for controlling natural, LP or manufactured gases
  • Close firmly with diaphragm that is both weight and spring loaded
  • 5 sec maximum valve opening and 2 sec maximum valve closing time
  • Valve closes on power failure and recommended for final shutoff service
  • Set opening time with various sized bleed orifices or adjustable bleed valve
  • Made with cast aluminum in straight-through body pattern
  • 1/8-27 NPT bleed and pilot tapping

    G636-64

Item#:
G636-64
Manufacturer Item:
V88A1618
Manufacturer:
HONEYWELL
White Rodgers Cooling Controls 3098-134 Mercury Flame Sensor for Proving Pilot Flame and Controlling Main Valve in Cycle Pilot Applications, 48" Element

G567-56

Item#:
G567-56
Manufacturer Item:
3098-134
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 767A-361 Silicon Carbide Hot Surface Igniter, 120 VAC, 5-1/4" L Lead

White Rodgers G568-23

Item#:
G568-23
Manufacturer Item:
767A-361
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Baso Y9 series inlet fittings control the flow of gas to a pilot burner and are designed to be used with baso pilot burners. The majority of baso inlet fittings have two holes which control and direct the flow of gas to the burner. The gas flow from the two holes intersects. This unique feature causes turbulence and a better gas/air mixture for proper combustion.

G512-12

Item#:
G512-12
Manufacturer Item:
Y90AA-4212C
Manufacturer:
JOHNSON CONTROLS, INC.
Honeywell VR8304P4504/U 1-Stage Intermittent Pilot/Spark Natural Step-Opening Combination Gas Control Valve, 3/4"

Honeywell G647-93

Item#:
G647-93
Manufacturer Item:
VR8304P4504
Manufacturer:
HONEYWELL
Honeywell VR8300A3500/U Combination Gas Control Valve, 1/2 x 3/4", 30000 - 290000 BTU

Honeywell G647-97

Item#:
G647-97
Manufacturer Item:
VR8300A3500
Manufacturer:
HONEYWELL
Honeywell VR8300A4508/U Combination Gas Control Valve, 3/4", 30000 - 300000 BTU
    Controls includes safety shut-off, manual valve, (2) automatic operators, pressure regulator and pilot adjustment
  • Compact size
  • Provides (2) automatic valves
  • Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends
  • Diaphragm operated second automatic valve opens under control of the regulator, closes if gas or power supply is interrupted
  • Meets codes requiring dual safety shut-off
  • Natural to LP and LP to natural conversion kits available for standard and slow opening gas valves
  • All adjustments, wiring connections and pilot outlet are accessible from top of gas control
  • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure
  • Compatible with ECO connector
  • Lite-Rite (off-pilot-on) lighting sequence
  • Includes natural to LP conversion kit, (2) 3/4 x 1/2" reducer bushing
  • 0 - 90 deg in any direction from the upright position of the gas control knob, including vertically mounting
  • Straight-through with flange body pattern
  • Standard pressure regulator
  • Mounting: 0 to 90 degs in any direction from the upright position of the gas control knob, including vertically

    Honeywell G647-98

Item#:
G647-98
Manufacturer Item:
VR8300A4508
Manufacturer:
HONEYWELL
The Robertshaw 700 Series Combination Gas Valves offer replacement flexibility. With three-position outlets and multi-positional capability, these combination gas valves offer unlimited replacement possibilities. The 24 Volt Uni-Kit models are suitable for either natural or LP gas. The valve is factory set at 3.5" WC natural gas. A regulator cover plate is included to convert to LP gas.

Robertshaw G647-99

Item#:
G647-99
Manufacturer Item:
700-400
Manufacturer:
ROBERTSHAW CONTROLS CO.
Robertshaw Controls G566-60 Hot Surface Ignition Control Module 780-34NL306A

G566-60

Item#:
G566-60
Manufacturer Item:
780-785
Manufacturer:
ROBERTSHAW CONTROLS CO.
The L62 series Baso safety shutoff devices are for use on all gas-fired, standing pilot equipment that requires main burner shutoff when the pilot is extinguished. Typical applications include domestic central heating and commercial space heating appliances, as well as industrial processing equipment (for example, die-casting machines and degreasers). Monitor the pilot flame through the use of a thermocouple. If the pilot flame is extinguished, the switch will interrupt gas flow to the main burner and pilot burner, shutting down the appliance.
    The L62 has a manual reset feature, and is available in models with or without 100% shut-off
  • The L62 has a thermo-electric power unit assembly that receives its energy from a heated thermocouple
  • If the pilot flame is extinguished, the main valve circuit is interrupted and gas flow to the main burner (and pilot burner in 100% shut-off model L62GB) is stopped
  • Both L62 models contain an electric interruption feature that only allows pilot gas flow during the lighting or resetting cycle
  • When lighting the pilot, the main valve electrical circuit is interrupted until the pilot flame is established and the reset button is released
  • Allows only pilot gas flow during lighting cycle
  • 1 conduit opening

    G570

Item#:
G570
Manufacturer Item:
L62AA-5
Manufacturer:
JOHNSON CONTROLS, INC.
|◀ 37 - 48 of 414 ▶|