Home  > TJERNLUND PRODUCTS INC(x)
View:
Tjernlund 950-1067 Adjustable Post-Purge Timer For GPAK-JT, SS1-R and VP-3F Venting Systems, 24/115 VAC , 1 - 10 min
Sid Harvey Item #:950-1067: Replaces Part #:'s : 6H201

tjernlund 950-1067

Item#:
950-1067
Manufacturer Item:
950-1067
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund 950-0625 Motor with Wheel Kit

Tjernlund 950-0625

Item#:
950-0625
Manufacturer Item:
950-0625
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund 950-1011 Steel Replacement Blower Wheel Kit for HS1, HSUL-1, HST-1, HS115-1, HS1 GPAK-1, PAI-3, GPAK-1, GPAK-1TR Power Venter
Sid Harvey Item #:950-1011: Replaces Part #:'s : 4G4294

Tjernlund 950-1011

Item#:
950-1011
Manufacturer Item:
950-1011
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund HS1 Steel Side Wall Power Venter with UC1 Control, 115 VAC at 60 Used for side wall venting residential/light commercial natural gas, LP or oil fired equipment including: Furnaces, boilers, water heaters and unit heaters. All models feature the new UC1 universal control and a diaphragm fan proving switch safety interlock which will shut down the heating equipment if a venting malfunction occurs. Built-in adjustable damper also allows regulation for maximum combustion efficiency. UC1 universal control features include, adjustable pre and post-purge settings, LED status/diagnostic indicators, fan prover switch monitoring. Interlocks with any 24 - 120 VAC burner control circuit and also includes dry contact actuation option. Easily interlock multiple appliances with our MAC-series multiple appliance controls. Sid Harvey Item #:HS1: Replaces Part #:'s : 21767
Item#:
HS1
Manufacturer Item:
HS-1
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund 950-1030 Fan Prover Kit For SS-1 Sidewall Power Venter
Item#:
950-1030
Manufacturer Item:
950-1030
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund D-3 Aluminized Steel Housing Inline Draft Inducer, 115 VAC, 0.96 amp, 1550 RPM, 1/20 HP
  • Venturi action starts air moving up the stack instantly and keeps it moving smoothly
  • In-line inducers are built for long-lasting, trouble-free service
  • Vari-draft control permits adjustment to individual job requirements
  • Vents/chimneys utilizing in-line draft inducers must be vertically terminated above the roof line
  • Solves venting problems: Undersized chimneys, negative pressures, long horizontal vent connectors, down drafts, cold equipment starts, restrictive heat exchangers/combustion chambers
  • 1 year warranty Tjernlund D-3 Aluminized Steel Housing Inline Draft Inducer, 115 VAC, 0.96 amp, 1550 RPM, 1/20 HP Sid Harvey Item #:106-1: Replaces Part #:'s : x89-444
Item#:
106-1
Manufacturer Item:
D-3
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund 950-0650 Fan Prover Kit SS-1
Item#:
950-0650
Manufacturer Item:
950-0650
Manufacturer:
TJERNLUND PRODUCTS INC
The SideShot models SS1 and SS2 SideWall Vent Systems include the UC1 Universal Control for increased safety, performance and reliability. Designed for oil fired heating equipment or a deluxe gas vent system. Patented vent termination propels flue gases at high velocities away from the building exterior, a necessity when venting oil fired equipment. Both models can be installed with zero clearance to combustible materials and have stainless steel construction in critical areas. Factory wired safety and operating controls allow simple interlock with any burner. The new model SS2 features a self-cleaning stainless steel, backward inclined impeller and sealed ball bearing motor for virtually maintenance free installations. Ultra-fine draft adjustment and slide-out access to all internal components. Easy multiple appliance interlocks with our MAC Series multiple appliance controls.
  • Use to side wall vent non-condensing oil fired boilers, water heaters and furnaces that otherwise would require a conventional roof top terminated chimney
  • Built-in interlock control with redundant high limit safety switch interfaces easily with thermostat, aquastat or primary controls
  • Adjustable pre and post purge timing and easy fault code retrieval
  • Stainless steel construction in all critical components including outdoor terminus
  • Patented design jets flue gases away from the outside wall to eliminate potential staining of siding
  • Slide out service drawer and material handling stainless steel impeller
Sid Harvey Item #:SS2: Replaces Part #:'s : 6H167A
Item#:
SS2
Manufacturer Item:
SS2
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund 950-0029 Fan Prover Kit SS-2
Item#:
950-0029
Manufacturer Item:
950-0029
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund 950-1020 Replacement Motor Kit
Sid Harvey Item #:950-1020: Replaces Part #:'s : 17H2731

Tjernlund 950-1020

Item#:
950-1020
Manufacturer Item:
950-1020
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund UC1 Control Board

tjernlund uc1

Item#:
UC1
Manufacturer Item:
UC-1
Manufacturer:
TJERNLUND PRODUCTS INC
The SideShot models SS1 and SS2 SideWall Vent Systems include the UC1 Universal Control for increased safety, performance and reliability. Designed for oil fired heating equipment or a deluxe gas vent system. Patented vent termination propels flue gases at high velocities away from the building exterior, a necessity when venting oil fired equipment. Both models can be installed with zero clearance to combustible materials and have stainless steel construction in critical areas. Factory wired safety and operating controls allow simple interlock with any burner. The new model SS2 features a self-cleaning stainless steel, backward inclined impeller and sealed ball bearing motor for virtually maintenance free installations. Ultra-fine draft adjustment and slide-out access to all internal components. Easy multiple appliance interlocks with our MAC Series multiple appliance controls.
  • Use to side wall vent non-condensing oil fired boilers, water heaters and furnaces that otherwise would require a conventional roof top terminated chimney
  • Built-in interlock control with redundant high limit safety switch interfaces easily with thermostat, aquastat or primary controls
  • Adjustable pre and post purge timing and easy fault code retrieval
  • Stainless steel construction in all critical components including outdoor terminus
  • Patented design jets flue gases away from the outside wall to eliminate potential staining of siding
Sid Harvey Item #:106-10: Replaces Part #:'s : 6H167
Item#:
106-10
Manufacturer Item:
SS1
Manufacturer:
TJERNLUND PRODUCTS INC
View: