Honeywell T651A3018/U Beige Non-Programmable Medium Duty Line VAC age Thermostat, 120 - 277 VAC , 44 - 86 deg F
,
- Light and medium duty line VAC age thermostats control line VAC age valves, motors, contractors, electric heat, elements, duct furnaces and fan coil units in heating/cooling systems
- Automatic cooling and heating anticipation
- Receptacles, small, containing gas, 2.1 hazmat information
- Super tradeline value
,
Honeywell C201-10
Item#:
C201-10
Manufacturer Item:
T651A3018
Manufacturer:
HONEYWELL
Honeywell L8124C1003 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
,
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC line voltage; at locked rotor: 44.4 amp at 120 VAC, 22.7 amp at 240 VAC line voltage
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- 1-1/2" depth insulation
,
Honeywell C317-5
Item#:
C317-5
Manufacturer Item:
L8124C1003
Manufacturer:
HONEYWELL
Honeywell C317-2 Aquastat Triple
Honeywell C317-2
Item#:
C317-2
Manufacturer Item:
L8124A1007
Manufacturer:
HONEYWELL
Honeywell Home C7189R1004/U Arctic White Wireless Indoor Air Temperature and Humidity Sensor, 0 - 120 deg F
,
- Used to sense temperature if the thermostat is installed in a poor temperature sensing location
- Small remote temperature sensor to match any room decor
- Easy to install and use
- Factory calibrated, no field calibration required
- Mounts on a vertical wall with supplied bracket and mounting hardware
- Sense temperature and humidity remotely, average temperature and humidify and dehumidify in separate location
,
Honeywell C7189R1004
Item#:
C7189R1004
Manufacturer Item:
C7189R1004
Manufacturer:
HONEYWELL
Resideo C554A1463 Cadmium-Sulfide Flame Detector,
,
,
Honeywell C554A1463
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPSTSid Harvey Item #:C317-8: Replaces Part #:'s : C318-8R,
,
Honeywell C317-8
Item#:
C317-8
Manufacturer Item:
L8124G1020
Manufacturer:
HONEYWELL
Honeywell L8124E1016 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
,
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: 1.25 amp at 24 VAC; 30 VA (total load) terminals B1-B2 and TV-Z
- Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC
,
Honeywell C317-7
Item#:
C317-7
Manufacturer Item:
L8124E1016
Manufacturer:
HONEYWELL
Resideo C874 Temperature Control SPDT -30F-+90F 8' Capillary,
,
,
Resideo C874
Honeywell C7232A1008 Carbon Dioxide Sensor CO2 W/LCD Display
Honeywell C7232A1008
Item#:
C7232A1008
Manufacturer Item:
C7232A1008
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
,
- Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
- Visible control point scale and External adjustments screw permit easy setting
- Horizontal insertion of the sensing element
- Direct/well immersion of the sensing element
- Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications
- Contacts break on temperature rise
- Screw terminals wiring
- Includes heat-conductive compound
,
Honeywell C290
Item#:
C290
Manufacturer Item:
L4006A1678
Manufacturer:
HONEYWELL
Honeywell C292 Aquastat Remote Bulb 5' Capillary SPST Break On Rise 100-240 Degrees,
,
,
Honeywell C292
Honeywell L8124A1015 Triple Aquastat Relay, 120 VAC
,
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- Includes 3" insertion well and ground screw
,
Honeywell C317-2B
Item#:
C317-2B
Manufacturer Item:
L8124A1015
Manufacturer:
HONEYWELL