Home  > HONEYWELL(x)
|◀ 121 - 132 of 545 ▶|
View:
Honeywell C7250A1001 Sensor MA 20K,
,



honeywell c7250a1001


honeywell c7250a1001

Item#:
C7250A1001
Manufacturer Item:
C7250A1001
Manufacturer:
HONEYWELL
Honeywell C7189R3002-2 Wall Mount Temperature Sensor 2 PACK White

Honeywell C7189R3002-2

Item#:
C7189R3002-2
Manufacturer Item:
C7189R3002-2/U
Manufacturer:
HONEYWELL

HONEYWELL C7189U1005

Item#:
C7189U1005
Manufacturer Item:
C7189U1005
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
  • Totally enclosed micro switch snap-acting switches operate on temperature rise to setpoint
  • Visible control point scale and external adjustments screw permit easy setting
  • Horizontal or vertical insertion of the sensing element
  • Remote buLbs. model may be used to sense air temperature in ducts and in outside air sensing applications
  • Direct or well immersion of the sensing element
  • Includes heat-conductive compound, well adapter Honeywell L4006E1067 High Limit Manual Reset Aquastat, 130 - 270 deg F, 10 - 25 deg F Differential

    Honeywell C290-6

Item#:
C290-6
Manufacturer Item:
L4006E1067
Manufacturer:
HONEYWELL

Resideo C335-2

Item#:
C335-2
Manufacturer Item:
L6006C1018
Manufacturer:
HONEYWELL
Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
  • Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
  • High limit opens burner circuit only
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • 1-1/2 - 3" depth less well insulation
  • Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
  • Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential

    Honeywell C312-9

Item#:
C312-9
Manufacturer Item:
L8148J1009
Manufacturer:
HONEYWELL
The L8148 Aquastat Relays are immersion type hydronic controllers that combine high limit protection with switching relay control of burner and circulator motors.

Honeywell C312-8

Item#:
C312-8
Manufacturer Item:
L8148A1017
Manufacturer:
HONEYWELL
Honeywell L4064B2210 Fan and Limit Switch for Forced Warm Air Heating Systems, 100 - 250 deg F High Limit
  • 3 wiring terminal options available for easy installation
  • Push-in receptacles for stripped wire
  • Female receptacles for 1/4" male flag connectors
  • Field add-on screw terminals
  • Controls adapt to many competitive mounting holes in replacement applications
  • Available in a variety of fan and high limit setting ranges
  • L4064B, W models have manual fan switch that overrides fan control to keep fan running continuously
  • Super tradeline models with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse
Sid Harvey Item #:C434-9: Replaces Part #:'s : C445-12 | FAL4064B2210-C434-9 |,
,



Honeywell C434-9


Honeywell C434-9

Item#:
C434-9
Manufacturer Item:
L4064B2210
Manufacturer:
HONEYWELL
Honeywell L4064B2228/U Fan and Limit Control, 120/240 VAC
  • Controls high limit and fan motors in forced air heating systems
  • Push-in receptacles for stripped wire
  • Female receptacles for 1/4" male flag connectors
  • Auxiliary screw terminals
  • Field adjustable fan and high limit settings
  • L4064B, W and R models have a manual fan switch that overrides the fan control to keep the fan running continuously
  • Tradeline models with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse
  • Turns fan on and off according to plenum temperature via helical bi-metal sensing element
  • High limit stop set at 200 deg F
  • Breakaway jumper included
  • Includes manual and automatic fan on/off settings
  • Maximum ambient 190 deg F switch: 350 deg F element, 100 - 250 deg F high limit, 65 - 215 deg F fan-on, 50 - 200 deg F fan-off, 200 deg F high limit stop, 125 deg F fan-on stop, 100 deg F fan-off stop
  • Fan switch makes and high limit switch breaks on temperature rise
  • 0.25 amp at 0.25 - 12 VDC, 2 amp at 24 VAC pilot duty
Sid Harvey Item #:C434-7: Replaces Part #:'s : C445-9 | FAL4064B2228-C434-7 |,
,



Honeywell C434-7


Honeywell C434-7

Item#:
C434-7
Manufacturer Item:
L4064B2228
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
    Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
  • Visible control point scale and external adjustments screw permit easy setting
  • Horizontal insertion of the sensing element
  • Direct/well immersion of the sensing element
  • Remote buLbs. model may be used to sense air temperature in ducts and in outside air sensing applications
  • Contacts make on temperature rise
  • Screw terminals wiring

    Honeywell C290-1A

Item#:
C290-1A
Manufacturer Item:
L4006B1163
Manufacturer:
HONEYWELL

HONEYWELL C7089R1013

Item#:
C7089R1013
Manufacturer Item:
C7089R1013
Manufacturer:
HONEYWELL

HONEYWELL C138-1

Item#:
C138-1
Manufacturer Item:
S483B1002
Manufacturer:
HONEYWELL
|◀ 121 - 132 of 545 ▶|
View: