S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
Honeywell C317-8
Item#:
C317-8
Manufacturer Item:
L8124G1020
Manufacturer:
HONEYWELL
Honeywell L8124E1016 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: 1.25 amp at 24 VAC; 30 VA (total load) terminals B1-B2 and TV-Z
- Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC
C317-7
Item#:
C317-7
Manufacturer Item:
L8124E1016
Manufacturer:
HONEYWELL
Honeywell L8124A1015 Triple Aquastat Relay, 120 VAC
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- Includes 3" insertion well and ground screw
Honeywell C317-2B
Item#:
C317-2B
Manufacturer Item:
L8124A1015
Manufacturer:
HONEYWELL
Honeywell C293-3 Aquastat Immersion High or Low Limit SPDT 110-240 Degrees,
Honeywell C293-3
Honeywell C293-3
Honeywell C293-3
Honeywell T498B1512/U Brush Gold Non-Programmable Electric Heat Thermostat, 1H, 120/208/240/277 VAC , 40 - 80 deg F
,
- Electric heat thermostats provide line VAC age control of electric heating systems
- Easy to install, color coded leads
- Rugged, plastic mounting base
- Mount on standard 2 x 4" outlet box or 4 x 4" junction box
- Select models include extra knob decal for recalibration, if necessary
,
HONEYWELL C182-5
HONEYWELL C182-5
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
- Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
- Visible control point scale and external adjustments screw permit easy setting
- Horizontal or vertical insertion of the sensing element
- Direct/well immersion of the sensing element
- Remote buLbs. model may be used to sense air temperature in ducts and in outside air sensing applications
- Contacts break on temperature rise
- Screw terminals wiring
Honeywell C290-6A
Honeywell L4064B2236 Fan and Limit Switch for Forced Warm Air Heating Systems, 100 - 250 deg F High Limit
,
- 3 wiring terminal options available for easy installation
- Push-in receptacles for stripped wire
- Female receptacles for 1/4" male flag connectors
- Field add-on screw terminals
- Controls adapt to many competitive mounting holes in replacement applications
- Available in a variety of fan and high limit setting ranges
- L4064B, W models have manual fan switch that overrides fan control to keep fan running continuously
- Super tradeline models with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse
,
Honeywell C434-12
Honeywell C434-12
Item#:
C434-12
Manufacturer Item:
L4064B2236
Manufacturer:
HONEYWELL
Honeywell Home DR65A3000 Dehumidifier 65 Pint 120 VAC,
DR65A3000
,
HONEYWELL DP1030A5014
HONEYWELL DP1030A5014
Item#:
DP1030A5014
Manufacturer Item:
DP1030A5014
Manufacturer:
HONEYWELL