S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Fieldpiece Instruments RSDMHOSE Replacement Tubing for Manometer 2 Pack
Item#:
RSDMHOSE
Manufacturer Item:
RSDMHOSE
Manufacturer:
FIELDPIECE INSTRUMENTS,INC
Fieldpiece Instruments RSMANK8 Valve and Knob Kit for SMAN4 and MAN460 Manifolds
Item#:
RSMANK8
Manufacturer Item:
RSMANK8
Manufacturer:
FIELDPIECE INSTRUMENTS,INC
Fieldpiece Instruments RSMANK6 Valve and Knob Kit for SMAN2 and SMAN3 Digital Manifolds
Item#:
RSMANK6
Manufacturer Item:
RSMANK6
Manufacturer:
FIELDPIECE INSTRUMENTS,INC
Fieldpiece Instruments RSO2 Replaceable Oxygen Smart Sensor
Item#:
RSO2
Manufacturer Item:
RS2
Manufacturer:
FIELDPIECE INSTRUMENTS,INC
Fieldpiece Instruments RVC5 Service Port Fitting for Valve Core Removal Tool 5/16"
Fieldpiece Instruments RVC4 Service Port Fitting for Valve Core Removal Tool 1/4"
Fieldpiece Instruments SC480 Wireless Clamp Meter True RMS Compatible with Job Link mobile app
Fieldpiece Instruments SC260 Compact Clamp Meter with True RMS, 600
Fieldpiece Instruments SCM4 Carbon Monoxide Detector Battery Powered
Fieldpiece Instruments The SDMN6 dual-port manometer measures gas and static pressure and also accurately tests pressure switches by simulating a draft with an internal pump. A pressure switch is a safety device that prevents the furnace from running in an unsafe manner. The SDMN6 tests the pressure switch to determine if it is working properly, or if it is starting to fail which can cause the furnace to run in an unsafe manner. Plus, with the SDMN6 you can easily calibrate any adjustable pressure switch to manufacturers' specification, so there's no need to carry a large variety of pressure switches on your truck. The Dual Port Manometer has the ranges to measure gas pressure and the resolution needed to measure static pressure. Ideal for HVACR field service technicians, the SDMN6 can determine if the gas pressure coming into the house or out of the regulator are correct. The SDMN6 measures gas pressure up to 60" WC with a resolution of 0.1" WC. In addition, the unit measures both positive and negative pressure, which is used for measurement on vacuum control lines. The unit will take differential pressure readings and display the difference between P1 and P2 at all times in the lower right corner of the easy-to-read LCD. Four different measurement scales can be used:"es of water column, millimeters of water column, Mbars, and PSI. The SDMN6 also has a zero adjust to zero out the meter in different ambient pressures. It has a hold button to hold the currently displayed reading. The auto-power-off function conserves battery life, but can be disabled if desired. In the static pressure mode, the unit can measure up to 2" WC with resolution to 0.010" WC, which enables a technician to measure small differences in air (or static) pressure
Fieldpiece Instruments The SDMN5 is a portable, rugged dual-port manometer designed especially for HVACR field service technicians. Measures gas pressure, static pressure and pressure differential. The SDMN5 includes a zero adjust button of the face of the meter, a rugged rubber boot, a magnet on the back for hanging the meter during service, and the Auto Power-Off (APO) function conserves battery life. The SDMN5 measures pressure between -6inWC and 6inWC ("es of water column) and -15. to 15. mBar. The SDMN5 also measures P1 or P2 pressure readings and calculates the difference between P1 and P2. Take static pressure measurements using the resolution mode of .1 in WC or .1 mBar. Includes 3/16 to 5/16 in adapter for measuring gas inlet and outlet pressures. The SDMN5 evolved as a result of testing pressures in the field for 2 years. Its range and resolution allow you to measure the HVAC applications you run into everyday in HVAC/R field service. Measure gas pressure on the inlet and outlets with the standard 3/16 in fittings or the included adapters for 5/16 in ports, take static pressure measurements across a blower and get the pressure differential with the push of a button to check drafts. Whether you're holding the ergonomic standalone shape in your hand or hang the SDMN5 on the unit with the magnetic hanger to fill out a work order, the SDMN5 make HVAC/R field service easier and faster, with less fatigue than the other guys.
- Measures duct pressures to balance air flow
- Resolution down to .1" WC for static pressure measurement
- .1" WC resolution
- 15 min auto power off
- Over range - OL or -OL is displayed
- 2 hr battery life with low battery LED indicator on displayed
- Battery - single standard 9 volt, NEDA 164, JIS 6P, IEC 6F22
- Compatible media - dry and non-corrosive gases
- SDMN5 Dual-Port Manometer, 2-3/16" Tubes with Brass Fittings, RMA316 2-3/16 - 5/16" Tube Adapters, 9 volt Battery (Installed), Operator's Manual, (2) 5/16" Adapters for Measuring Inlet and Outlet Pressures
Fieldpiece Instruments SDP2 Dual In-Duct Psychrometer, 0 - 100%, -4 to 140 The SDP2 dual In-duct psychrometer is more than just your everyday HVACR psychrometer. It gives HVACR professionals more insight into HVAC evaporator performance than any other psychrometer, because it takes four evaporator measurements at one time: supply wet bulb, supply dry bulb, return wet bulb, and return dry bulb. So HVACR professionals get a live, real-time snap shot of the evaporator performance, even while conditions are changing. Based on these live, dynamic readings, the SDP2 dual In-duct psychrometer registers system changes as they happen, and automatically calculates actual Delta-T, Target Delta-T, actual Evaporator Exit Temperature, and Target Evaporator exit temperature. Plus enthalpy (BTU/LBM) and dew point can be displayed in real-time. The SDP2 is a great tool to help HVACR professionals do more all by itself