Fieldpiece Instruments S365 Charging JacketCharging Jacket is a reliable way to charge TXV systems in cold weather. Normally, low temperatures remove too much heat from the condenser coils, so HVACR professionals should only work on TXV systems when the outside air temperature is 70 deg F or higher. Now, the new Fieldpiece Charging Jacket solves that problem, and TXV systems can be accurately charged down to 37 deg F outside temps. It's the perfect tool to dramatically extend the hours in a day, and the days in a year, where techs can install, service, and charge TXV systems. Made from parachute-grade material, the Charging Jacket is attached to the top of a split TXV system with hooks, so that the air inlet is not restricted. Then the unit is turned on the jacket puffs up from the air being forced out of the air outlet. The top is then adjusted with a drawstring until the proper pressure differential is reached between the high and low side (between 160 psi and 220 psi for R410A; and between 100 psi and 145 psi for R22). Once the systems stabilizes for 15 minutes at the correct pressure differential, the system is ready to be charged.
,
- Charge TXV systems in cold weather
- Charge TXV systems from 37 - 70 deg F outside
- Service maintenance contracts before and after the summer heat
- Easy to adjust to reach correct pressure differential
- Great way to increase business during the slow season
- Field tested for accuracy
- Looks professional
- Extend billable hours
- There is no other product on the market made specifically for this purpose
- Currently, HVACR professionals either do not work on TxV systems if it is below 70 deg F outside, or, if it's an emergency techs might use their actual jackets or cardboard to block the air inlet
- The problem is those methods are inaccurate
- The charging jacket's advantage is that it works to bring the pressure drop across the TxV to at least 160 psi and therefore has the same effect on the system as higher temperatures do
- HVACR professionals can now dramatically extend their billable hours because they can work on systems during the off season
- So instead of having the do service contract check-ups during the summer rush, service and maintenance can be start early in the spring, and continue late into the fall
- And even year-round in many parts of the country
- Parachute grade
,
Fieldpiece Instruments S365
Fieldpiece Instruments S365
Fieldpiece Thermocouple Pipe Clamp,
,
,
Fieldpiece Instruments TC48
Fieldpiece Instruments TC48
Item#:
TC48
Manufacturer Item:
TC48
Manufacturer:
FIELDPIECE INSTRUMENTS,INC
Fieldpiece Instruments TC24 Type K Thermocouple Pipe Clamp, 3/8 - 1-3/8,
,
,
Fieldpiece Instruments TC24
Fieldpiece Instruments TC24
Feildpiece VPX7 Vacuum Pump 2-Stsge 10 CFM 120 VAC With RunQuick Oil Change System,
,
,
Feildpiece VPX7
Feildpiece VPX7
Fieldpiece Instruments VP87 Vacuum Pump 8 CFM 2-Stage 115 VAC
VP87
VP87
Fieldpiece Instruments VP67 Vacuum Pump 5 CFM 2-Stage 115 VAC
VP67
VP67
Fieldpiece Instruments VC1G Valve Core RemovalTool 1/4" Single Valve W/Sightglass
Cello WP02-12-10
Fieldpiece Instruments VC2G Valve Core RemovalTool 1/4"Double Valve W/Sightglass