|◀ 373 - 384 of 627 ▶|
View:
Sid Harvey Remanufactured R80-32R Control Relay Combination Control Horizontal REMANUFACTURED,

R80-32R

Item#:
R80-32R
Manufacturer Item:
R8182D1111
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-30R Combination Protectorelay (W/Well Adapter) REMANUFACTURED,

R80-30R

Item#:
R80-30R
Manufacturer Item:
R8182D1079
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R80-58R Combination Protectorelay and Hydronic Heating Controller, 120 VAC, 4.4 amp Full Load, 26.4 amp Locked Rotor Burner at 120 VAC, 9 watt, Remanufactured
  • Immersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems
  • Use in intermittent ignition applications
  • Capable of zone control with zone valves
  • Circulator zone control with ZC and ZR terminals on R8182D, E, H, J
  • 8-flame failure during the running cycle results in a 45 sec attempt to restart
  • If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted
  • C554A cadmium sulfide flame detector and a 24 VAC thermostat required
  • Includes auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A switching relay, horizontal case
  • Maximum 250 deg F at element, 15 deg F fixed high limit differential temperature
  • 45 sec safety switch timing
  • 1/2"-14 NPT well spud size
  • 0.2 amp anticipator setting
  • 1-1/2" insulation depth,

    R80-58R

Item#:
R80-58R
Manufacturer Item:
R8182J1059
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Protectorelay RA117A Universal Relay, 120 VAC , 75 sec Nominal
    Interrupted ignition type
  • Combine a Protectorelay unit for cycling the burner and a Pyrostat flame detector for sensing temperature changes of flue gases up to 1000 deg F
  • Manual reset of safety switch required after ignition failure completely shuts off main burner
  • Include manual trip safety switch to assure burner shutdown during servicing
  • Mount with flange for mounting on curved or flat surfaces
  • Works with 2-wire and 3-wire 24 VAC thermostat
  • 2 years warranty

    R22R

Item#:
R22R
Manufacturer Item:
RA117A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R75-61R 2-Wire CAD Cell Relay, 24 volt, Remanufactured
  • Ignition comes on for duration of safety timing if flame fails during operation

    R75-61R

Item#:
R75-61R
Manufacturer Item:
R8404AA
Manufacturer:
SID HARVEY REMANUFACTURED
Skuttle A00-1708-002 Black Rubber Valve Seat for Skuttle 45, 48, 77, 86, Honeywell HE120, White Rodgers Cooling Controls HDT2600 Humidifiers

Skuttle L26-24

Item#:
L26-24
Manufacturer Item:
A00-1708-002
Manufacturer:
SKUTTLE MFG CO
Sid Harvey Honeywell R8184M Oil Burner Primary Control for C554A Cadmium Sulfide Cell and 24VAC Thermostat, 120/26.5 VAC , 9 amp

R75-58R

Item#:
R75-58R
Manufacturer Item:
R8184M
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R5R Interrupted Ignition Stack Relay, 120 volt, Remanufactured
  • Remanufactured with 100% pure, solid silver Pyrostat contacts for longer on-the-job service life
  • Backed by 2-year warranty
  • All new stack relays contain brass contacts covered with a slight silver plating, it wears off as the contacts open and close, exposing the brass surface over time, the exposed surface is a poor conductor and may result in relay failure and nuisance callbacks

    R5R

Item#:
R5R
Manufacturer Item:
RA817A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell R8184G4074 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 VAC
    Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout Remote lockout indication
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • With 30 sec safety timing, alarm outputs and manual safety switch

    R75-42R

Item#:
R75-42R
Manufacturer Item:
R8184G4074
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R75-41R Oil Burner Primary Control R8184G Plastic Box 15 Second REMANUFACTURED,

R75-41R

Item#:
R75-41R
Manufacturer Item:
R75-41R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 VAC
    Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • With 15 sec safety timing, alarm outputs and manual safety switch
Sid Harvey Item #:R75-40R: Replaces Part #:'s : R75-39R | R75-40 | ICM150

R75-40R

Item#:
R75-40R
Manufacturer Item:
R8184G4009
Manufacturer:
SID HARVEY REMANUFACTURED
Item#:
ZDBP1016
|◀ 373 - 384 of 627 ▶|