|◀ 1 - 12 of 627 ▶|
View:
Honeywell L4064B2228/U Fan and Limit Control, 120/240 VAC
    Controls high limit and fan motors in forced air heating systems
  • Push-in receptacles for stripped wire
  • Female receptacles for 1/4" male flag connectors
  • Auxiliary screw terminals
  • Field adjustable fan and high limit settings
  • L4064B, W and R models have a manual fan switch that overrides the fan control to keep the fan running continuously
  • Tradeline models with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse
  • Turns fan on and off according to plenum temperature via helical bi-metal sensing element
  • High limit stop set at 200 deg F
  • Breakaway jumper included
  • Includes manual and automatic fan on/off settings
  • Maximum ambient 190 deg F switch: 350 deg F element, 100 - 250 deg F high limit, 65 - 215 deg F fan-on, 50 - 200 deg F fan-off, 200 deg F high limit stop, 125 deg F fan-on stop, 100 deg F fan-off stop
  • Fan switch makes and high limit switch breaks on temperature rise
  • 0.25 amp at 0.25 - 12 VDC, 2 amp at 24 VAC pilot duty >

    Honeywell C434-7

Item#:
C434-7
Manufacturer Item:
L4064B2228
Manufacturer:
HONEYWELL
Honeywell L4064B2236 Fan and Limit Switch for Forced Warm Air Heating Systems, 100 - 250 deg F High Limit
    3 wiring terminal options available for easy installation
  • Push-in receptacles for stripped wire
  • Female receptacles for 1/4" male flag connectors
  • Field add-on screw terminals
  • Controls adapt to many competitive mounting holes in replacement applications
  • Available in a variety of fan and high limit setting ranges
  • L4064B, W models have manual fan switch that overrides fan control to keep fan running continuously
  • Super tradeline models with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse

    Honeywell C434-12

Item#:
C434-12
Manufacturer Item:
L4064B2236
Manufacturer:
HONEYWELL
Honeywell S87D1004 Direct Spark Ignition Control Module, 24 VAC, 60 Hz, 1-15/16" L x 4-1/16" W x 5-1/4" H
    Control ignition sequence and gas control operation
  • Generate high voltage potential for main burner ignition
  • Lockout after one trial for ignition if main burner fails to ignite
  • Reset from thermostat after lockout
  • Use modules with any combination gas control designed for direct spark applications and rated 2 amp or less

    honeywell g565-36

Item#:
G565-36
Manufacturer Item:
S87D1004
Manufacturer:
HONEYWELL
Honeywell S688A1007 Polyester Film 10" Switch with 5" Sail, SPDT
    Activates an electronic air cleaner, a humidifier, or other equipment in response to airflow from the system fan
  • Mounted in the return air duct where the sail will be in the direct path of an unrestricted air stream
  • Polyester film sail mounted on a micro switch snap switch
  • Removable spring counterbalances sail to allow mounting in either vertical (up or down) or horizontal air flow
  • Simplified installations with multi-speed fans, inaccessible air handlers, fan motors with voltage or phase different from controlled equipment, eliminated wiring to system fan
  • Top and bottom conduit knockouts for wiring convenience
  • Low air velocity switch operation makes at 250 fpm and breaks at 75 fpm
  • 10" insertion
  • 26.2 sq-inch area sail

    HONEYWELL R308-2

Item#:
R308-2
Manufacturer Item:
S688A1007
Manufacturer:
HONEYWELL
Resideo ST9120U1011 Universal Electronic Fan Timer For Control of Combustion Blower for a Gas Warm Air Appliances, 18 - 30 VAC
    Replaces 40+ existing Resideo electronic fan timers
  • Instruction sheet supplies full cross reference and wiring guide
  • Interface harnesses for simple conversion
  • Dip switch selectable heat and cool delay on and off times
  • Electronic air cleaner and humidifier terminal connections
  • Continuous low speed indoor air circulation
  • Integrates control of all combustion blower and circulating fan operations in gas warm-air appliance
  • Replaceable fuse
  • Heat fan on delay - adjustable 30, 60 sec ( set at 30 sec)
  • Heat fan off delay - adjustable 60, 120, 150, 180 sec (set at 120 sec)
  • Cool fan on delay - adjustable 4, 30 sec (set at 4 sec)
  • Cool fan off delay - adjustable 30, 60 sec (set at 30 sec)
Sid Harvey Item #:ST9120U1011: Replaces Part #:'s : ST9101A1014 | ST9101A1022 | ST9120A2004 | ST9120C2002 | ST9120C2010 | ST9120C3000 | ST9120C3018 | ST9120C4008 | ST9120C4016 | ST9120C4040 | ST9120C4057 | ST9120C5005 | ST9120C5013 | ST9120D3009 | ST9120G2024 | ST9120G4004 | ST9120G4038 | ST9120U1003 | ST9141A1002 | ST9141A1028 | ST9141B1001 | ST9150A1003 | ST9150B2000 | ST9150B2018 | ST9150B2026 | ST9150C4057 | ST9160A1002 | ST9160B1001 | ST9160B1019 | ST9160B1027 | ST9160B1035 | ST9160B1043 | ST9160B1050 | ST9160B1068 | ST9160B1076 | ST9160C1000 | ST9160C1018

honeywell st9120u1011

Item#:
ST9120U1011
Manufacturer Item:
ST9120U1011
Manufacturer:
HONEYWELL
Honeywell TP970A2004 Pneumatic Thermostat 60-90 2 Pipe

honeywell tp970a2004

Item#:
TP970A2004
Manufacturer Item:
TP970A2004
Manufacturer:
HONEYWELL
Resideo Y8610U Intermittent 1 or 2-Rod Natural Gas/LP Pilot Retrofit Kit for Gas-Fired Atmospheric Furnaces, 24 VAC
    Intermittent pilot retrofit kits save energy by converting atmospheric standing pilot systems to intermittent pilot
  • Use with natural or LP gas
  • Provides 100% pilot gas shutoff if pilot fails to light, after 6 min delay, trial for ignition is repeated
  • Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed
  • 2 sec flame failure response time
  • 0 or 30 sec pre-purge time
  • Ignition sequence - continuous retry, after trial for ignition, pilot gas shuts off for 5 min then another trial for pilot ignition takes place
  • Typical gas control - VR8204, VR8304
  • Ignition source - internal high voltage spark generator
  • Ignition trials to lockout - continuous retry
  • 1 amp pilot, 2 amp at 24 VAC maximum valve load
  • Q345, Q3451 typical ignition hardware
  • 15 or 90 sec lockout timing and ignition trial time
  • VR8204, VR8304 typical gas control

    honeywell y8610u4001

Item#:
Y8610U4001
Manufacturer Item:
Y8610U4001
Manufacturer:
HONEYWELL
E.S.P. Company UHS24 Humidifier Solenoid Valve Replacement Kit 24 VAC,

ESP Company UHS24

Item#:
UHS24
Manufacturer Item:
UHS24
Manufacturer:
ESP COMPANY
Sid Harvey B163-14R Power Head Assembly V8043E-B REMANUFACTURED,

B163-14R

Item#:
B163-14R
Manufacturer Item:
V8043E-B
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Protectorelay RA116A Universal Relay, 120 VAC , 75 sec Nominal
    Interrupted ignition type
  • Combine a Protectorelay unit for cycling the burner and a Pyrostat flame detector for sensing temperature changes of flue gases up to 1000 deg F
  • Manual reset of safety switch required after ignition failure completely shuts off main burner
  • Include manual trip safety switch to assure burner shutdown during servicing
  • Mount with flange for mounting on curved or flat surfaces
  • Works with 2-wire and 3-wire 24 VAC thermostat
  • 2 years warranty
    Sid Harvey Remanufactured R20R

    R20R

Item#:
R20R
Manufacturer Item:
RA116A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-52R Protectorelay & Hydronic Heating Controller for Oil Hydronic System REMANUFACTURED,

R80-52R

Item#:
R80-52R
Manufacturer Item:
R8182E
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-40R Combination Protectorelay 5' Remote Bulbs. REMANUFACTURED,

R80-40R

Item#:
R80-40R
Manufacturer Item:
R8182H1070
Manufacturer:
SID HARVEY REMANUFACTURED
|◀ 1 - 12 of 627 ▶|