|◀ 1465 - 1476 of 1697 ▶|
View:
White Rodgers Cooling Controls 5059-134 Pilot Relite Control, 24 VAC, 0.03 amp
  • Generates spark pulse until flame is sensed through spark electrode
  • Begins sparking immediately if flame extinguishes
  • Rugged solid state module design
  • Spike terminal high voltage and 1/4" spade terminals connection
Sid Harvey Item #:5059-134: Replaces Part #:'s : CNT01011,

White Rodgers 5059-134

Item#:
5059-134
Manufacturer Item:
5059-134
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50E70-820 HSI Integrated Furnace Control, 18 - 30 VAC, 60 Hz
  • 1-stage applications
  • 120 volt HSI ignition
  • Adapter board and harness included
  • For packaged units
  • Flame current test pins
  • Red and green status LEDs
  • Standoffs/adapter board mounting
  • 0.8 sec flame establishing time, 2 sec flame failure response time at 60 Hz
  • Flame current requirements - minimum current to insure flame detection: 1 micro-amp DC, maximum current for non-detection: 0.1 micro-amp DC, maximum allowable leakage resistance: 100 mega-ohm

    White Rodgers 50E70-820

Item#:
50E70-820
Manufacturer Item:
50E70-820
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50D50-842 Universal DSI Control for Gas-Fired Non-Integrated Forced Air Furnaces, Boilers, 25 VAC, 0.2 amp, 4.13" W x 4.13" H x 1-1/2" D
  • Color LED indicator for diagnostics
  • Includes program keys, double-sided foam back tape, color coded timing label, pre-printed hanging carTon
  • 1/4 and 3/16" quick connect terminals
  • Direct and indirect flame sense

    White Rodgers 50D50-842

Item#:
50D50-842
Manufacturer Item:
50D50-842
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50D50-843 Universal Intermittent Pilot Spark Ignition Module for Gas-Fired Non-Integrated Forced Air Furnaces, 25 VAC, 0.2 amp, 4.13" W x 4.13" H x 1-1/2" D
  • Color LED indicator for diagnostics
  • Includes program keys, double-sided foam back tape, color coded timing label, pre-printed hanging carTon
  • 1/4 and 3/16" quick connect terminals
  • Direct and indirect flame senseSid Harvey Item #:50D50-843: Replaces Part #:'s : CSA35A-617R | CSA35A-618R | CSA42A-600R | CSA42A-601R | CSA42A-602R | CSA42A-603R | CSA42A-604R | CSA43A-600R | CSA44A-600R | CSA45A-601R | CSA45A-602R | CSA46A-600R | CSA48A-600R | CSA49A-600R | CSA49A-605R | CSA51A-601R | CSA52A-600R

    White Rodgers 50D50-843

Item#:
50D50-843
Manufacturer Item:
50D50-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56-743 Hot Surface Igniter Nitride Integrated Furnace Control, 25 VAC, 0.45 amp, 50/60 Hz
  • System diagnostic LED with fault recall
  • Multi speed circulator
  • 1 or 2-stage gas valve
  • Relay load ratings - 1.5 amp at 25 VAC 50/60 Hz 0.6 pico-F valve relay, 6 amp at 120 VAC 50/60 Hz (resistive) igniter relay, 2.2 amp full load, 3.5 amp locked rotor at 120 VAC inducer relay, 14.5 amp full load, 25 amp locked rotor at 120 VAC circulator relay
  • Flame current requirements - 1 micro-amp DC minimum current to insure flame detection, 0.10 micro-amp DC maximum current for non-detection, 100 mega-ohm maximum allowable leakage resistance
  • 0.8 sec flame establishing time, 2 sec flame failure response time

    White Rodgers 50M56-743

Item#:
50M56-743
Manufacturer Item:
50M56-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
The 50A66-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.
  • 3-fan speeds
  • Remote flame sensing
  • Humidifier and electronic air cleaner connections (optional)
  • 1.5 amp valve relay
  • 6 amp igniter relay
  • 2.2 amp full load - 3.5 amp locked rotor inducer relay
  • 14.5 amp full load - 25 amp locked rotor circulator relay
  • Diagnostic indicator flash codes, controls gas valve, igniter, blower, inducer, humidifier and air cleaner

    White Rodgers 50A66-743

Item#:
50A66-743
Manufacturer Item:
50A66-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50D50-801 Pilot Spark Ignition Control for Gas Appliance 18-30 VAC 0.2 amp

White Rodgers 50D50-801

Item#:
50D50-801
Manufacturer Item:
30W33
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Amatex Corporation 7058 High Density Rope 1/2",

Amatex Corporation 7058

Item#:
7058
Manufacturer Item:
7058
Manufacturer:
AMATEX CORPORATION
Amatex Corporation 7059 High Density Rope 5/8",

Amatex Corporation 7059

Item#:
7059
Manufacturer Item:
7059
Manufacturer:
AMATEX CORPORATION
Beckett Parts Parts 7610B0001U AquaSmart Boiler Temperature Control (120V), Gas W/ Temp. ONLY Sensor (24V Burner Circuit)

Beckett Parts 7610B0001U

Item#:
7610B0001U
Manufacturer Item:
7610B0001U
Manufacturer:
RW BECKETT CORP
Beckett Parts Parts 7610B0001U AquaSmart Boiler Temperature Control (120V), Gas W/ Temp. ONLY Sensor (24V Burner Circuit)

Beckett Parts 7610B0001U

Item#:
7610B0001U
Manufacturer Item:
7610B0001U
Manufacturer:
RW BECKETT CORP
  • Series Application Universal Intermittent Pilot Ignition Module
  • Input Power 24VAC ± 4VAC 50-60 Hz
  • Input Current Max 0.25 A + Valve at 2A Max
  • High Voltage Output 15 KV with 50 pf load
  • Spark Gap 0.150 in ± 0.050 in (3.8 mm ± 1.2 mm)
  • Flame Sensor Current 0.5 Microamperes (uA) minimum
  • Flame Failure Re-Ignition Time Maximum 1 second
  • Vent Damper Optional, use Molex 03-06-2061
  • Ambient Temperature -40 °F to + 176 °F (-40 °C to +80 °C)
  • Humidity Range Up to 95% relative humidity non-condensing
  • UPC 662013256449

    Robertshaw 780U-IP10

  • Item#:
    780U-IP10
    Manufacturer Item:
    780U-IP10
    Manufacturer:
    ROBERTSHAW CONTROLS CO.
    |◀ 1465 - 1476 of 1697 ▶|