|◀ 1693 - 1704 of 1709 ▶|
View:
Arzel PAN-HPP03 Control Panel 3-Zone 24 VAC Heat Pump
    Residential & light commercial four zones or less
  • Single or multi-stage equipment
  • Variable speed Furnace Air conditioner Heat pump Dual fuel
  • Independent blower & compressor staging
  • Outdoor Air Temperature (OAT) sensor
  • Leaving Air Temperature (LAT) sensor
  • LCD display
  • Zone weight percentage
  • Replaceable fuse protection
  • Easy to use lever style terminals
  • Manual pump switch opens all dampers for testing
Item#:
PAN-HPP03
Manufacturer Item:
PAN-HPP03
Manufacturer:
ARZEL SOLUTION-BASED COMFORT
Honeywell SPRD08 Zonefirst SPRD Static Pressure Bypass Regulating Damper 8"
Item#:
SPRD08
Manufacturer Item:
SPRD08
Manufacturer:
HONEYWELL
Rectangular Blade Damper Bottom Mount,
Item#:
ZD8X10TZ
Manufacturer Item:
ZD8X10TZ/U
Manufacturer:
HONEYWELL
Field Controls 00963801 Silver Barometric Draft Control for Residential Oil, Wood and COverall Length, 6"
    M control lends itself ideally to conditions requiring a great deal of stability and accuracy
  • Designed for settings from 0.01 - 0.1"
  • Type M features an infinitely variable screw adjustment, permitting an extremely fine instrument setting
  • M employs side wings to control air direction with gate curvatures designed to compensate for differences in horizontal and vertical settings
Item#:
100
Manufacturer Item:
00963801
Manufacturer:
FIELD CONTROLS LLC
Tjernlund 100-12 Barometric Draft Damper Gas 7"-8",
Item#:
100-12
Manufacturer Item:
01986501
Manufacturer:
FIELD CONTROLS LLC
Bell & Gossett 112113 EASB-1-1/4 JR Enhanced Air Separator, 1-1/4", NPT, 150 psi, 250 deg F, Brass, 4-5/8" W x 7-1/2" H
    Automatically removes entrained air bubbles in hydronic system
  • Stainless steel cOverall Lengthescing medium, non ferrous venting mechanism
Item#:
112113
Manufacturer Item:
112113
Manufacturer:
BELL & GOSSETT ITT
SPECIFICATIONS:
  • Electrical Ratings: [@ 77°F (25°C)]
  • Input Voltage 25 VAC 60 Hz
  • Max. Input Current 0.8A @ 25 VAC
  • Flame Current Requirements:
  • Min. Current to ensure flame detection 0.37 A DC
  • Max. current for non-detection 0.1 A DC
  • Max. allowable leakage resistance 100 M Ohms
  • Note: Flame current shown on 7-Segment LED display in heating mode
  • Manual option: Measured with a DC voltmeter on Test Pins (1 VDC = 1 A)
  • Operating Temp Range: -40° to 176°F (-40 to 80°C)
  • Humidity Range: 5% to 93% relative humidity (noncondensing)
  • Gases Approved: Natural, Manufactured, Mixed, Liquid
  • Petroleum, and LP Gas Air mixtures all approved for use
  • Dimensions: 6.5" W x 8.25" L x 1.50" D (with tabs) 5.5" W x 7.0" L x 1.50" D (tabs removed)
  • Agency Approvals: UL - USA / Canada
  • Item#:
    50M56X-843
    Manufacturer Item:
    50M56X-843
    Manufacturer:
    WHITE-RODGERS DIV OF COPELAND
    White Rodgers Cooling Controls 50D50U-843 Universal Intermittent Pilot All Spark 24V Ignition Module,White Rodgers 50D50U-843
    Item#:
    50D50U-843
    Manufacturer Item:
    50D50U-843
    Manufacturer:
    WHITE-RODGERS DIV OF COPELAND
    Diversified Heat Transfer 68W-5 Residential Tankless Coil for Weil-McLain
    Item#:
    B42-3
    Manufacturer Item:
    68W-5
    Manufacturer:
    DIVERSIFIED HEAT TRANSFER INC.
    Oatey 31008 Heavy-Duty PVC Cement, 32 oz, Clear, 12/Pack
    • Thick formula fills gaps in large diameter pipe and loose fitting joints
    • Recommended for potable water, pressure pipe, conduit and DWV Oatey heavy duty clear PVC solvent cement is recommended for solvent welding all schedules and classes of PVC pipe and fittings up to 12" diameter, and non-pressure applications up to 18" with interference fit. Heavy duty clear PVC solvent cement can be used for potable water, sewer and drain, waste and vent systems. This product is compliant with California South Coast Air Quality Management District (SCAQMD) Rule 1168 and Ozone Transport Commission (OTC) regulations for volatile organic compound emission levels.
    Item#:
    31008
    Manufacturer Item:
    31008
    Manufacturer:
    OATEY S.C.S
    Taco Flo-Checks prevent gravity circulation in forced hot water heating systems during periods when the boiler is hot, but the space heating zone is not wanted. This makes it possible to use the heating boiler to maintain domestic hot water year-round. You can also use Flo-Checks in systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat. In addition, the thumb screw can be opened manually for gravity feed applications, if the main circulator stops operating.
      In systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat
    • Feature a thumb screw to manually open the valve and are available in a cast iron universal body and a bronze sweat in-line configuration
    • The thumb screw can be opened manually for gravity feed applications, if the main circulator stops operating
    • Open automatically when the circulator starts running, when the room thermostat is satisfied and the circulator is stopped, the flo-checks close immediately, preventing gravity circulation
    • Water or glycol media
    Item#:
    B146-22
    Manufacturer Item:
    221-6
    Manufacturer:
    TACO INC.
    Taco flo-cheks have dependably stopped gravity circulation in forced hot water heating systems for over 40 years. Flo-cheks open automatically when the circulator starts running. They feature a thumb screw to manually open the valve and are available in a cast iron universal body and a bronze sweat in-line configuration.
      Flo-cheks allow heat to flow only into the zones that are calling for heat
    • Thumb screw can be manually opened for gravity feed applications if the main circulator stops operating
    • Taco flo-cheks open automatically when the circulator starts running
    Sid Harvey Item #:B146-20: Replaces Part #:'s : HYD160-B146-20 | 4030 |
    Item#:
    B146-20
    Manufacturer Item:
    218-3
    Manufacturer:
    TACO INC.
    |◀ 1693 - 1704 of 1709 ▶|
    View: