Brand Name
Type
|◀ 25 - 36 of 36 ▶|
View:
Sid Harvey C312-10R High Limit Aquastat Relay, 100 - 240 deg F1>

C312-10R

Item#:
C312-10R
Manufacturer Item:
C312-10
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290R Aquastat, 100 - 240 deg F, 5 - 30 deg F Mid-Scale Sid Harvey Item #:C290R: Replaces Part #:'s : AQU4006A1678-C290 | AQU4006A2007-C290A | C290 | C290A |,

C290R

Item#:
C290R
Manufacturer Item:
L4006A1678-2007
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C434-9R Fan Limit Control, Remanufactured
  • ,

    C434-9R

Item#:
C434-9R
Manufacturer Item:
C434-9
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
  • Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
  • High limit opens burner circuit only
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • 1-1/2 - 3 Inch depth less well insulation
  • Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
  • Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential,

    C312-9R

Item#:
C312-9R
Manufacturer Item:
L8148J1009
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-7R Fan limit Control 5'' REMANUFACTURED,

C434-7R

Item#:
C434-7R
Manufacturer Item:
C434-7R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C293-3R Aquastat Immersion SPDT 100-240 Degrees REMANUFACTURED,

C293-3R

Item#:
C293-3R
Manufacturer Item:
L6006A1145
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C322-4R Dual Aquastat, 130 - 240 deg F High Limit, 110 - 220

C322-4R

Item#:
C322-4R
Manufacturer Item:
L4081B1096-1047
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124A High and Low Limit Circulator Triple Aquastat Relay, 120 VAC, 130 - 240 deg F Adjustable High Limit, 110 - 220 deg F Adjustable Low Limit
    Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)

    C317-2R

Item#:
C317-2R
Manufacturer Item:
L8124A1007,1015,1098
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-73R Heat Timer EPU-CH Blue Panel REMANUFACTURED,

C346-73R

Item#:
C346-73R
Manufacturer Item:
C346-73R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-72R Heat Timer EPU Blue Panel REMANUFACTURED,

C346-72R

Item#:
C346-72R
Manufacturer Item:
C346-72R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C346-58R Discharge Water Control, 80 - 220 deg F, 24/120/240,

C346-70R

Item#:
C346-70R
Manufacturer Item:
C346-70R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290R Aquastat, 100 - 240 deg F, 5 - 30 deg F Mid-Scale,

C332-6R

Item#:
C332-6R
Manufacturer Item:
L6081A1010
Manufacturer:
SID HARVEY REMANUFACTURED
|◀ 25 - 36 of 36 ▶|