Brand Name
Brand Name
Type
Type
|◀ 13 - 24 of 36 ▶|
View:
Sid Harvey Remanufactured C346-72R Heat Timer EPU Blue Panel REMANUFACTURED,

C346-72R

,

C346-72R

Item#:
C346-72R
Manufacturer Item:
C346-72R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-73R Heat Timer EPU-CH Blue Panel REMANUFACTURED,

C346-73R

,

C346-73R

Item#:
C346-73R
Manufacturer Item:
C346-73R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C312-10R High Limit Aquastat Relay, 100 - 240 deg F
Sid Harvey Item #:C312-10R: Replaces Part #:'s : 0R258,

C312-10R

,

C312-10R

Item#:
C312-10R
Manufacturer Item:
C312-10
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey High Limit Aquastat Relay 8F differential REMANUFACTURED. Immersion type controllers that combine high limit protection with switchingrelay control of burner and circulator motors
  • High limit opens burner circuit only.
  • Includes transformer and accessory terminals for adding a remote low limit controller.
  • Case available for horizontal or vertical mounting.
  • Requires a 24 VAC thermostat with heat anticipator set at 0.2 amps.
Sid Harvey Item #:C312-8R: Replaces Part #:'s : 0R257,

C312-8R

,

C312-8R

Item#:
C312-8R
Manufacturer Item:
L8148A1017
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor

C317-8R

Item#:
C317-8R
Manufacturer Item:
L8124G1020
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124C High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-5R: Replaces Part #:'s : C317-5R,

C317-5R

,

C317-5R

Item#:
C317-5R
Manufacturer Item:
L8124C1003
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124E High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-7R: Replaces Part #:'s : C317-7

C317-7R

Item#:
C317-7R
Manufacturer Item:
L8124E1016
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124L High Limit Triple Aquastat Relay, 24 - 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-11R: Replaces Part #:'s : AQU8124L1011-C317-11 | C317-11 |,

C317-11R

,

C317-11R

Item#:
C317-11R
Manufacturer Item:
L8124L1011
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124A High and Low Limit Circulator Triple Aquastat Relay, 120 VAC, 130 - 240 deg F Adjustable High Limit, 110 - 220 deg F Adjustable Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-2R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317R,

C317-2R

,

C317-2R

Item#:
C317-2R
Manufacturer Item:
L8124A1007,1015,1098
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey B163-14R Power Head Assembly V8043E-B REMANUFACTURED,

B163-14R

,

B163-14R

Item#:
B163-14R
Manufacturer Item:
V8043E-B
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured B112-8R Electric Water Feeder 24 VAC REMANUFACTURED,

B112-8R

,

B112-8R

Item#:
B112-8R
Manufacturer Item:
169500
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Mcdonnell & Miller 169400 Electric Water Feeder, 2350000 BTU/hr Output, Import
  • Eliminates necessity to manually add water to the boiler
  • Can be used with mechanical or electronic low water cut-off controls
  • Quick-change replaceable cartridge valve and strainer
  • Manual feed button Mcdonnell & Miller 169400 Electric Water Feeder, 2350000 BTU/hr Output, Import,

    B112-10R

    ,

    B112-10R

Item#:
B112-10R
Manufacturer Item:
169400
Manufacturer:
SID HARVEY REMANUFACTURED
|◀ 13 - 24 of 36 ▶|
View: