S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Brand Name
BTU
Voltage
Position
Fujitsu FHSMTT4824SAZTNAN00
Item#:
FHSMTT4824SAZTNAN00
Manufacturer Item:
FHSMTT4824SAZTNAN00
Manufacturer:
FUJITSU
STANDARD FEATURES
Refrigerant leak detection dissipation system for added safety
Multi-tap ECM (electronic commutating motor) motors all sizes.
Integrated motor controls, with 90-sec off TDR function, have
replaced integrated circuit board.
Five available speed tags to meet a wide range of applications.
Large, grooved tube, louvered fin coils.
Efficient, quiet, time-tested blower housings and diffusers.
Sturdy, drainable condensate pans.
Construction innovations designed to prevent cabinet sweating.
Tested for condensate disposal in much tougher conditions than Air
Conditioning and Refrigeration Institute requirements.
Super-thick R-4.2 insulation with vapor barrier.
Pre-painted galvanized steel cabinet (dark grey).
Design meets stringent regulations for cabinet air leakage of less than
2% when tested at 0.5 inches W.C., and less than 1.4% at 0.5 inches
W.C. when tested in accordance with ASHRAE 193 standard.
Installation-flexible, multipoise units. 2-piece modular design
available for 42 thru 60 sizes. Facilitates attic and crawlspace
installations..
Horizontal hanging provisions on cabinet.
Newly improved filter rack area filter door insulation added for
improved air seal. No tools required to access filter.
3 through 30 kW accessory heaters - field installed.
Easy plug-in provisions for heater installation.
Entry options for high and low voltage wiring hook-up.
Leak-preventing sweat connections.
Factory installed thermostatic expansion valve, TXV, on all coils.
Designed for manufactured housing applications
Item#:
FHMA5B42L0CA
Manufacturer Item:
FHMA5B42L0CA
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
FHRATT3621MJZTNA
Item#:
FHRATT3621MJZTNA
Manufacturer Item:
FHRATT3621MJZTNA
Manufacturer:
FUJITSU
MULTIFAMILY CEILING MOUNT FAN COIL
FMU5Z and FMC5Z 1-1/2, 2, 2-1/2, and 3 Tons
Horizontal application only
Accessory field-installed electric heat kits available in 3, 5, 6, 7.5, or
10 kW
40VA, 208/230V-1-60 transformer
All models use Puron Advance, R-454B refrigerant and have a
hard-shutoff TXV metering device
Adjustable condensate drain pan
FM(C,U)5X, FM(C,U)5Z
Horizontal return applications require field fabricated bottom cover
Cabinets meet the requirement of 1.4% cabinet leakage rate when
tested to ASHRAE Standard 193
Cabinets insulated to prevent cabinet sweating
Refrigerant lines and electrical connections can be run out the back or
side of casing
Performance
PSC motor on all FMU5X & FMC5X models
ECM motor on all FMU5Z & FMC5Z models
Easy To Install Service
A-coil design for maximum surface area
Multiple electrical, refrigerant lineset and drain line entry for
application flexibility
Primary and secondary drain connections exit from the back or side
of the cabinet
Supports furred-down ceiling open return and ducted return
applications
Sweat connections for long term reliability
Grooved aluminum tube / aluminum fin coils on FMU5X, FMC5X,
FMC5Z, and FMU5Z models with AL in the 10th & 11th position
Item#:
FMU5Z3000AL
Manufacturer Item:
FMU5Z3000AL
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
FHRATT3621MAZTNA
Item#:
FHRATT3621MAZTNA
Manufacturer Item:
FHRATT3621MAZTNA
Manufacturer:
FUJITSU
FHFSPS3624SJZTNAN00
Item#:
FHFSPS3624SJZTNAN00
Manufacturer Item:
FHFSPS3624SJZTNAN00
Manufacturer:
FUJITSU
MULTIFAMILY CEILING MOUNT FAN COIL
FMU5Z and FMC5Z 1-1/2, 2, 2-1/2, and 3 Tons
Horizontal application only
Accessory field-installed electric heat kits available in 3, 5, 6, 7.5, or
10 kW
40VA, 208/230V-1-60 transformer
All models use Puron Advance, R-454B refrigerant and have a
hard-shutoff TXV metering device
Adjustable condensate drain pan
FM(C,U)5X, FM(C,U)5Z
Horizontal return applications require field fabricated bottom cover
Cabinets meet the requirement of 1.4% cabinet leakage rate when
tested to ASHRAE Standard 193
Cabinets insulated to prevent cabinet sweating
Refrigerant lines and electrical connections can be run out the back or
side of casing
Performance
PSC motor on all FMU5X & FMC5X models
ECM motor on all FMU5Z & FMC5Z models
Easy To Install Service
A-coil design for maximum surface area
Multiple electrical, refrigerant lineset and drain line entry for
application flexibility
Primary and secondary drain connections exit from the back or side
of the cabinet
Supports furred-down ceiling open return and ducted return
applications
Sweat connections for long term reliability
Grooved aluminum tube / aluminum fin coils on FMU5X, FMC5X,
FMC5Z, and FMU5Z models with AL in the 10th & 11th position
Item#:
FMU5X3600AL
Manufacturer Item:
FMU5X3600AL
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
FHRNPS3621SJZTNA
Item#:
FHRNPS3621SJZTNA
Manufacturer Item:
FHRNPS3621SJZTNA
Manufacturer:
FUJITSU
Fujitsu FH3621TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
Fujitsu FH3621TPSJSN
Item#:
FH3621TPSJSN
Manufacturer Item:
FH3621TPSJSN
Manufacturer:
FUJITSU
FHFSTT3624SJZTNAB03
Item#:
FHFSTT3624SJZTNAB03
Manufacturer Item:
FHFSTT3624SJZTNAB03
Manufacturer:
FUJITSU
FHFSPS1821SJZTNAB08
Item#:
FHFSPS1821SJZTNAB08
Manufacturer Item:
FHFSPS1821SJZTNAB08
Manufacturer:
FUJITSU
Fujitsu FH6021TTSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
FH6021TTSJSN
Item#:
FH6021TTSJSN
Manufacturer Item:
FH6021TTSJSN
Manufacturer:
FUJITSU(UNITARY)