S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Rear flue Lowboy with PSC Direct Drive Blower Motor and Beckett AFG Burner,
,
,
Thermo Pride VL8RA119P60B
Item#:
VL8RA119P60B
Manufacturer Item:
VL8RA119P60B
Manufacturer:
THERMO PRODUCTS, LLC
Warran WHE1002Bx Electric Strip Heater 240/1 10 KW,
,
,
Warren Technology WHE1002BX
Warren WHE0502BX Electric Heater 240 VAC 5KW 230 VAC
Warren Technology WHE0502BX
Warren WHE1002X Electric Heater 240 VAC 10KW 230 VAC
,
,
,
,
Warren Technology WHE1002X
This smart new concept in commercial heating units will accommodate all architects who are looking for something new and different.
Reznor WS23/33C
Item#:
WS23/33C
Manufacturer Item:
WS23/33C
Manufacturer:
REZNOR LLC
Nortek Global(Reznor) X-250 Duct Furnace Suspended 250K BTU Gravity Vented 120 VAC
Reznor X-250
Item#:
X-250
Manufacturer Item:
X-250
Manufacturer:
REZNOR LLC
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling or heat pump heating.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surface ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent using indoor
combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York Z9ET080B12SMPS1
Item#:
Z9ET080B12SMPS1
Manufacturer Item:
Z9ET080B12SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Blower-off delay for cooling SEER2 improvement
Easy access to controls to connect power and control wiring
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation
Low unit current requirement for easy replacement application
All models are convertible to use propane (LP) gas.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety
Five-speed direct drive standard ECM blower motor
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling
Hi-tech tubular aluminized steel primary heat exchanger
Timed on, adjustable off blower capability for maximum comfort
Blower door safety switch
Solid removable bottom panel allows easy conversion for bottom return air applications
Low NOx models have been designed to meet specific code requirements.
Airflow leakage less than 1% of nominal airflow for duct performance testing conditions
No electrical knockouts to deal with, making installation easier
Fold-up duct connector flanges for application flexibility
Quiet inducer operation
Inducer rotates for easy conversion of venting options
Fully supported blower assembly for easy access and removal of blower
External air filters are used for maximum flexibility in meeting customers' indoor air quality
(IAQ) needs.
Venting applications: install as a common vent with other gas-fired appliances or use a lined
masonry chimney.
1/4 turn knobs are provided for easy independent door removal.
High-efficiency blower motor for lower electrical power usage and improved AC SEER2 ratings
Insulated blower compartment for thermal and acoustic performance
Item#:
Z8ES060A12SMPS1
Manufacturer Item:
Z8ES060A12SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal
right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications
on B, C, and D cabinets where side discharge is not
possible.
The unit cabinet is compact and easy to install with an
ideal height of 33 in.
Full length fold-up duct connector flanges for
application flexibility.
Easy access to controls to connect power and control
wiring.
No electrical knockouts to deal with, making
installation easier.
24 V, 40 VA control transformer and control provisions
supplied for single or multi-stage add on cooling.
Built-in, high level self diagnostics with fault code
displays standard on integrated control module for
reliable operation.
Front-facing screws on flame sensor and hot surgace
ignitor for ease of service.
Front-facing screws on blower assembly for easy
access and removal of blower.
Constant torque blower motor for cooling SEER2
enhancement.
Blower-off delay for cooling SEER2 improvement
Item#:
Z9ES100C16SMPS1
Manufacturer Item:
Z9ES100C16SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling or heat pump heating.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surface ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent using indoor
combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York Z9ET100C16SMPS1
Item#:
Z9ET100C16SMPS1
Manufacturer Item:
Z9ET100C16SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Blower-off delay for cooling SEER2 improvement
Easy access to controls to connect power and control wiring
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation
Low unit current requirement for easy replacement application
All models are convertible to use propane (LP) gas.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety
Five-speed direct drive standard ECM blower motor
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling
Hi-tech tubular aluminized steel primary heat exchanger
Timed on, adjustable off blower capability for maximum comfort
Blower door safety switch
Solid removable bottom panel allows easy conversion for bottom return air applications
Low NOx models have been designed to meet specific code requirements.
Airflow leakage less than 1% of nominal airflow for duct performance testing conditions
No electrical knockouts to deal with, making installation easier
Fold-up duct connector flanges for application flexibility
Quiet inducer operation
Inducer rotates for easy conversion of venting options
Fully supported blower assembly for easy access and removal of blower
External air filters are used for maximum flexibility in meeting customers' indoor air quality
(IAQ) needs.
Venting applications: install as a common vent with other gas-fired appliances or use a lined
masonry chimney.
1/4 turn knobs are provided for easy independent door removal.
High-efficiency blower motor for lower electrical power usage and improved AC SEER2 ratings
Insulated blower compartment for thermal and acoustic performance
Item#:
Z8ES080B12SMPS1
Manufacturer Item:
Z8ES080B12SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Blower-off delay for cooling SEER2 improvement
Easy access to controls to connect power and control wiring
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation
Low unit current requirement for easy replacement application
All models are convertible to use propane (LP) gas.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety
Five-speed direct drive standard ECM blower motor
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling
Hi-tech tubular aluminized steel primary heat exchanger
Timed on, adjustable off blower capability for maximum comfort
Blower door safety switch
Solid removable bottom panel allows easy conversion for bottom return air applications
Low NOx models have been designed to meet specific code requirements.
Airflow leakage less than 1% of nominal airflow for duct performance testing conditions
No electrical knockouts to deal with, making installation easier
Fold-up duct connector flanges for application flexibility
Quiet inducer operation
Inducer rotates for easy conversion of venting options
Fully supported blower assembly for easy access and removal of blower
External air filters are used for maximum flexibility in meeting customers' indoor air quality
(IAQ) needs.
Venting applications: install as a common vent with other gas-fired appliances or use a lined
masonry chimney.
1/4 turn knobs are provided for easy independent door removal.
High-efficiency blower motor for lower electrical power usage and improved AC SEER2 ratings
Insulated blower compartment for thermal and acoustic performance
Item#:
Z8ES040A12SMPS1
Manufacturer Item:
Z8ES040A12SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM