S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Features
Small footprint - Minimum footprint for easier handling, transportation, and installation.
Easier installation - Independent panels provide quick access for unit setup. Installation time is reduced by
easy power and control wiring access. Select indoor matches with factory-mounted TXVs are available for
quicker system installation. The filter-drier is shipped loose for installation in the field. The unit is factorycharged
for 15 ft refrigeration piping. The small base dimension and reduced unit clearances make for easier
retrofits.
Accessible information - QR code on unit provides quick access to technical documents and warranty
information.
Durable finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent
galvanized steel chassis components resist corrosion and rust creep. Modern Mist colored powdercoat paint
further protects external panels.
Quality coils - The high efficiency microchannel aluminum coil is manufactured using an improved material
system, providing reliable performance and small unit size.
Rugged coil protection - Coils are protected from mechanical damage by a proven stamped steel coil guard
design.
Protected compressor - Compressors are protected internally by a high-pressure relief valve and a
temperature sensor, and externally by the system high-pressure switch.
Reliable operation - Ball bearing fan motors provide superior performance in extreme temperatures.
Environmentally friendly - CFC-free R-454B refrigerant delivers environmentally friendly performance with
zero ozone depletion.
Top discharge - Warm air is blown up, away from the structure and any landscaping, allowing compact location
on multi-unit applications.
Low operating sound levels - Developed using CFD and FEA tools, the sturdy cabinet and top design provides
sound performance of 77 dBA or lower. Compatible accessories for further sound reduction are also available.
Better service access - Diagonal base valves with open access for low-loss fittings, single panel access to the
electrical controls, swing out control box for full corner access, and removable fan guard allow easy access for
unit maintenance.
Agency listed - Safety certified by CSA to UL 60335-2-40/CSA C22.2. Performance certified to ANSI/AHRI
Standard 210/240 in accordance with the Unitary Small Equipment certification program.
York XC336E3S11
Item#:
XC336E3S11
Manufacturer Item:
XC336E3S11
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling or heat pump heating.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surface ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent using indoor
combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York Z9ET080B12SMPS1
Item#:
Z9ET080B12SMPS1
Manufacturer Item:
Z9ET080B12SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling or heat pump heating.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surface ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent using indoor
combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York Z9ET100C16SMPS1
Item#:
Z9ET100C16SMPS1
Manufacturer Item:
Z9ET100C16SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling or heat pump heating.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surface ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent using indoor
combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York Z9ET080C16SMPS1
Item#:
Z9ET080C16SMPS1
Manufacturer Item:
Z9ET080C16SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling or heat pump heating.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surface ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent using indoor
combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York Z9ET060B12SMPS1
Item#:
Z9ET060B12SMPS1
Manufacturer Item:
Z9ET060B12SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling or heat pump heating.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surface ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent using indoor
combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York Z9ET040A10SMPS1
Item#:
Z9ET040A10SMPS1
Manufacturer Item:
Z9ET040A10SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling or heat pump heating.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surface ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent using indoor
combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York Z9ET100C20SMPS1
Item#:
Z9ET100C20SMPS1
Manufacturer Item:
Z9ET100C20SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side
discharge is not possible.
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Full length fold-up duct connector flanges for application flexibility.
Easy access to controls to connect power and control wiring.
No electrical knockouts to deal with, making installation easier.
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling or heat pump heating.
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation.
Front-facing screws on flame sensor and hot surface ignitor for ease of service.
Front-facing screws on blower assembly for easy access and removal of blower.
Constant torque blower motor for cooling SEER2 enhancement.
Blower-off delay for cooling SEER2 improvement.
Continuous fan options for indoor air quality (IAQ) performance.
Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
Low unit current requirement for easy replacement application.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety.
Inducer rotates for easy conversion of venting options.
Five-speed direct drive standard ECM blower motor.
Hi-tech tubular aluminized steel primary heat exchanger.
Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front
vestibule panel.
Quiet inducer operation.
Timed on, adjustable off blower capability for maximum comfort.
Blower door safety switch below the blower deck.
Solid removable bottom panel allows easy conversion for bottom return air applications.
External air filters are used for maximum flexibility in meeting customers' IAQ needs.
1/4 turn knobs are provided for easy independent door removal.
Insulated blower compartment for thermal and acoustic performance.
Internal condensate trap design (patent pending) provides condensate management options
and is self priming to prevent nuisance problems.
Protection included from air intake, exhaust vent, or condensate blockage. Venting applications
may be installed as either two-pipe sealed combustion or single-pipe vent using indoor
combustion air.
No special vent termination required.
These condensing furnace models produce <40 ng/J NOx emissions.
Fold-up duct connector flanges for application flexibility.
Patented self-priming internal condensate trap design for easy installation.
York Z9ET120D20SMPS1
Item#:
Z9ET120D20SMPS1
Manufacturer Item:
Z9ET120D20SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Electric Strip Heater 10.6 KW
York 2EH04511025
Item#:
2EH04511025
Manufacturer Item:
2EH04511025
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Electric Strip Heater 11 KW
York 2EH04511006
Item#:
2EH04511006
Manufacturer Item:
2EH04511006
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Electric Strip Heater 15.9 KW
York 2EH04511525
Item#:
2EH04511525
Manufacturer Item:
2EH04511525
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Electric Strip Heater 16 KW
York 2EH04511506
Item#:
2EH04511506
Manufacturer Item:
2EH04511506
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM