Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Blower-off delay for cooling SEER2 improvement
Easy access to controls to connect power and control wiring
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation
Low unit current requirement for easy replacement application
All models are convertible to use propane (LP) gas.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety
Five-speed direct drive standard ECM blower motor
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling
Hi-tech tubular aluminized steel primary heat exchanger
Timed on, adjustable off blower capability for maximum comfort
Blower door safety switch
Solid removable bottom panel allows easy conversion for bottom return air applications
Low NOx models have been designed to meet specific code requirements.
Airflow leakage less than 1% of nominal airflow for duct performance testing conditions
No electrical knockouts to deal with, making installation easier
Fold-up duct connector flanges for application flexibility
Quiet inducer operation
Inducer rotates for easy conversion of venting options
Fully supported blower assembly for easy access and removal of blower
External air filters are used for maximum flexibility in meeting customers' indoor air quality
(IAQ) needs.
Venting applications: install as a common vent with other gas-fired appliances or use a lined
masonry chimney.
1/4 turn knobs are provided for easy independent door removal.
High-efficiency blower motor for lower electrical power usage and improved AC SEER2 ratings
Insulated blower compartment for thermal and acoustic performance
Item#:
Z8ES100B12SMPS1
Manufacturer Item:
Z8ES100B12SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal
right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications
on B, C, and D cabinets where side discharge is not
possible.
The unit cabinet is compact and easy to install with an
ideal height of 33 in.
Full length fold-up duct connector flanges for
application flexibility.
Easy access to controls to connect power and control
wiring.
No electrical knockouts to deal with, making
installation easier.
24 V, 40 VA control transformer and control provisions
supplied for single or multi-stage add on cooling.
Built-in, high level self diagnostics with fault code
displays standard on integrated control module for
reliable operation.
Front-facing screws on flame sensor and hot surgace
ignitor for ease of service.
Front-facing screws on blower assembly for easy
access and removal of blower.
Constant torque blower motor for cooling SEER2
enhancement.
Blower-off delay for cooling SEER2 improvement
Item#:
Z9ES040A10SMPS1
Manufacturer Item:
Z9ES040A10SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal
right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications
on B, C, and D cabinets where side discharge is not
possible.
The unit cabinet is compact and easy to install with an
ideal height of 33 in.
Full length fold-up duct connector flanges for
application flexibility.
Easy access to controls to connect power and control
wiring.
No electrical knockouts to deal with, making
installation easier.
24 V, 40 VA control transformer and control provisions
supplied for single or multi-stage add on cooling.
Built-in, high level self diagnostics with fault code
displays standard on integrated control module for
reliable operation.
Front-facing screws on flame sensor and hot surgace
ignitor for ease of service.
Front-facing screws on blower assembly for easy
access and removal of blower.
Constant torque blower motor for cooling SEER2
enhancement.
Blower-off delay for cooling SEER2 improvement
Item#:
Z9ES060B12SMPS1
Manufacturer Item:
Z9ES060B12SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
York 1RC0471 Roof Curb 14"
York 1RC0471
Item#:
1RC0471
Manufacturer Item:
1RC0471
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
York 1RC0444 Roof Curb 14"
York 1RC0444
Item#:
1RC0444
Manufacturer Item:
1RC0444
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
York 1RC0434 Roof Curb 14"
York 1RC0434
Item#:
1RC0434
Manufacturer Item:
1RC0434
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Electric Strip Heater 10.6 KW
York 2EH04511025
Item#:
2EH04511025
Manufacturer Item:
2EH04511025
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Electric Strip Heater 11 KW
York 2EH04511006
Item#:
2EH04511006
Manufacturer Item:
2EH04511006
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
York 2EE04717625 Field Installed Ecomizer Kit
York 2EE04717625
Item#:
2EE04717625
Manufacturer Item:
2EE04717625
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
York 2EE04709024 Economizer Low Leak
York 2EE04709024
Item#:
2EE04709024
Manufacturer Item:
2EE04709024
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Electric Strip Heater 15.9 KW
York 2EH04511525
Item#:
2EH04511525
Manufacturer Item:
2EH04511525
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM