S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Resideo R8285D5001 Fan Center for 24 VAC Fan Control Applications, Heating, Air Conditioning, 120 VAC, 11 watt, 4-1/2" W x 4-3/16" H x 2-13/16" D
,
- Transformer powers low voltage control systems and provides overload protection
- Low voltage terminal board provides convenient connections for thermostat and heating and cooling equipment wiring
- Mounts on standard 4 x 4" junction box
- Relay is easily replaced without disturbing wiring
,
HONEYWELL R8285D5001
HONEYWELL R8285D5001
Item#:
R8285D5001
Manufacturer Item:
R8285D5001
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184G4082 Oil Burner Control
,
- With 45 sec safety timing and alarm outputs
- Provides automatic, nonrecycling control of an intermittent ignition oil burner system
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)
,
R75-44
R75-44
Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 volt
,
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 15 sec safety timing, alarm outputs and manual safety switch
,
honeywell r75-40
honeywell r75-40
Item#:
R75-40
Manufacturer Item:
R8184G4009
Manufacturer:
HONEYWELL
,
Honeywell R8222V1003
Honeywell R8222V1003
Item#:
R8222V1003
Manufacturer Item:
R8222V1003
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184M1051 Oil Burner Control for Boilers, 120 - 240 VAC
,
- Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
- Intermittent ignition is on while the burner is on
- Solid state flame sensing circuit
- External button to manually reset safety switch after lockout
- Enclosed safety switch must be manually reset after safety shutdown
- R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
,
honeywell r75-58
honeywell r75-58
,
Honeywell R8845U1003
Honeywell R8845U1003
Item#:
R8845U1003
Manufacturer Item:
R8845U1003
Manufacturer:
HONEYWELL
,
Honeywell R8222B1067
Honeywell R8222B1067
Item#:
R8222B1067
Manufacturer Item:
R8222B1067
Manufacturer:
HONEYWELL
Resideo R8285B1053/U Fan Center, SPST, 120/208/240 VAC Primary, 26.5 volt Secondary
,
- Provides low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or air conditioning systems
- Transformer powers low voltage control systems and provides overload protection
- Low voltage terminal board provides convenient connections for thermostat and heating and cooling equipment wiring
- Mounts on standard 4 x 4" junction box
- Relay is easily replaced without disturbing wiring
- Includes R8222D general purpose switching relay
- Contact rating - 12 amp full load, 60 amp locked rotor
,
Honeywell R8285B1053
Honeywell R8285B1053
Item#:
R8285B1053
Manufacturer Item:
R8285B1053
Manufacturer:
HONEYWELL
Resideo R8285A1048 Fan Center
- 120 VAC 40 VA SPDT,
,HONEYWELL R8285A1048
HONEYWELL R8285A1048
Item#:
R8285A1048
Manufacturer Item:
R8285A1048
Manufacturer:
HONEYWELL
Honeywell R7847A1033/U Green Rectifying Flame Amplifier for Primary Safety Control7800 Series Relay
,
- Solid state plug-in amplifiers that respond to flame detector inputs to indicate the presence of flame when used with 7800 series relay modules
- Flame failure response time of 2 or 3 sec
- Flame signal strength ranges from 0 - 5 VDC
- Plug into 7800 relay module through printed circuit board edge connector keyed for proper orientation
- Flame signal test jacks to measure amplifier flame signal voltage
- Color coded labels identify flame detection type
- Dynamic self-check amplifier test the detectors and all electronic components in the flame detection system 7800 series relay module locks out on safety shutdown with flame detection system failure
- Compatible with existing Honeywell flame detectors
- Use with flame sensor gas rectifying flame rods C7004, C7005, C7007, C7008, C7009, Q179; gas, oil, coal ultraviolet flame sensor C7012A, C
,
R7847A1033
R7847A1033
Item#:
R7847A1033
Manufacturer Item:
R7847A1033
Manufacturer:
HONEYWELL
Resideo R8239B176 Fan Center, 12/28/24 VAC Primary, 26.5 volt Secondary, DPDT
,
- Includes NEMA standard type D transformer powers 24 VAC control systems and relay enclosure
- Provides overload protection for transformer
- Convenient connections for thermostat and heating and cooling equipment wiring
- Can be mounted in any indoor location without additional enclosure
- Relay is easily replaced without disturbing wiring
,
HONEYWELL R8239B1076
HONEYWELL R8239B1076
Item#:
R8239B1076
Manufacturer Item:
R8239B1076
Manufacturer:
HONEYWELL
,
Honeywell R8225D1003
Honeywell R8225D1003
Item#:
R8225D1003
Manufacturer Item:
R8225D1003
Manufacturer:
HONEYWELL
