Honeywell Protectorelay R8184G4066/U Non-Recycle Oil Burner Control with Safety Timing, 4-1/8" W x 4-3/8" H x 2-1/2" Depth
  • Provides automatic, non-recycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 volts thermostat required
  • 15 second safety timing, alarm outputs, and manual safety switch
  • Intermittent ignition timing
Sid Harvey Item #:R75-37: Replaces Part #:'s : R75-37R,
,



honeywell r75-37


honeywell r75-37

Item#:
R75-37
Manufacturer Item:
R8184G4066
Manufacturer:
HONEYWELL

HONEYWELL R8285D5001

Item#:
R8285D5001
Manufacturer Item:
R8285D5001
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184G4082 Oil Burner Control
  • With 45 sec safety timing and alarm outputs
  • Provides automatic, nonrecycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)
Sid Harvey Item #:R75-44: Replaces Part #:'s : L40-026,
,



R75-44


R75-44

Item#:
R75-44
Manufacturer Item:
R8184G4082
Manufacturer:
HONEYWELL
Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 volt
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • With 15 sec safety timing, alarm outputs and manual safety switch
Sid Harvey Item #:R75-40: Replaces Part #:'s : R75-39R | R75-40R | ICM150,
,



honeywell r75-40


honeywell r75-40

Item#:
R75-40
Manufacturer Item:
R8184G4009
Manufacturer:
HONEYWELL

Honeywell R8222V1003

Item#:
R8222V1003
Manufacturer Item:
R8222V1003
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184M1051 Oil Burner Control for Boilers, 120 - 240 VAC
  • Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
  • Intermittent ignition is on while the burner is on
  • Solid state flame sensing circuit
  • External button to manually reset safety switch after lockout
  • Enclosed safety switch must be manually reset after safety shutdown
  • R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
Sid Harvey Item #:R75-58: Replaces Part #:'s : R75-58R,

,



honeywell r75-58


honeywell r75-58

Item#:
R75-58
Manufacturer Item:
R8184M1051
Manufacturer:
HONEYWELL

Honeywell R8845U1003

Item#:
R8845U1003
Manufacturer Item:
R8845U1003
Manufacturer:
HONEYWELL

Honeywell R8222B1067

Item#:
R8222B1067
Manufacturer Item:
R8222B1067
Manufacturer:
HONEYWELL

Honeywell R8285B1053

Item#:
R8285B1053
Manufacturer Item:
R8285B1053
Manufacturer:
HONEYWELL

HONEYWELL R8285A1048

Item#:
R8285A1048
Manufacturer Item:
R8285A1048
Manufacturer:
HONEYWELL
Honeywell R7847A1033/U Green Rectifying Flame Amplifier for Primary Safety Control7800 Series Relay
  • Solid state plug-in amplifiers that respond to flame detector inputs to indicate the presence of flame when used with 7800 series relay modules
  • Flame failure response time of 2 or 3 sec
  • Flame signal strength ranges from 0 - 5 VDC
  • Plug into 7800 relay module through printed circuit board edge connector keyed for proper orientation
  • Flame signal test jacks to measure amplifier flame signal voltage
  • Color coded labels identify flame detection type
  • Dynamic self-check amplifier test the detectors and all electronic components in the flame detection system 7800 series relay module locks out on safety shutdown with flame detection system failure
  • Compatible with existing Honeywell flame detectors
  • Use with flame sensor gas rectifying flame rods C7004, C7005, C7007, C7008, C7009, Q179; gas, oil, coal ultraviolet flame sensor C7012A, C
,
,



R7847A1033


R7847A1033

Item#:
R7847A1033
Manufacturer Item:
R7847A1033
Manufacturer:
HONEYWELL

HONEYWELL R8239B1076

Item#:
R8239B1076
Manufacturer Item:
R8239B1076
Manufacturer:
HONEYWELL