  • 11/2, 2, 21/2, and 3 Tons

    Upflow application only

    Accessory fieldinstalled electric heat kits available in 5, 7.5, or 10 kW

    208/230160 supply voltage

    Cabinet exterior is galvanized sheet metal

    Cabinet air leakage rate below 1.4% when tested to ASHRAE Standard 193

    Insulated for conditioned space (not to be installed in unconditioned spaces)

    All Aluminum coils

    FMA4P

    For use with R410A refrigerant utilizing standard piston

    FMA4X

    R410A refrigerant, TXV standard

    PERFORMANCE

    PSC motor on all FMA4P

    ECM motor on all FMA4X

    Motor suspended on rubber grommets for quieter operation

    Fresh air intake knockouts in cabinet

    EASY TO INSTALL AND SERVICE

    Units fits between standard stud spacings

    All service access is located in the front

    Primary and secondary drain connections exit from the bottom, access panel in bottom of cabinet

    No returnair ductwork required in specific applications

    Wall hanging brackets included with the unit
  • Item#:
    FMA5X1808AL
    Manufacturer Item:
    FMA5X1808AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • 11/2 thru 5 tons
  • Available for Environmentally Sound R410A systems
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models
  • Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left
    standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • Item#:
    FXM4X2400AL
    Manufacturer Item:
    FXM4X2400AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • 11/2 thru 5 tons
  • Available for Environmentally Sound R410A systems
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models
  • Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left
    standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied

    INTERNATIONAL COMFORT PRODUCTS FXM4X4200AL

  • Item#:
    FXM4X4200AL
    Manufacturer Item:
    FXM4X4200AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    MULTIFAMILY CEILING MOUNT FAN COIL
  • FMU5Z and FMC5Z 1-1/2, 2, 2-1/2, and 3 Tons
  • Horizontal application only
  • Accessory field-installed electric heat kits available in 3, 5, 6, 7.5, or 10 kW
  • 40VA, 208/230V-1-60 transformer
  • All models use Puron Advance, R-454B refrigerant and have a hard-shutoff TXV metering device
  • Adjustable condensate drain pan FM(C,U)5X, FM(C,U)5Z
  • Horizontal return applications require field fabricated bottom cover
  • Cabinets meet the requirement of 1.4% cabinet leakage rate when tested to ASHRAE Standard 193
  • Cabinets insulated to prevent cabinet sweating
  • Refrigerant lines and electrical connections can be run out the back or side of casing Performance
  • PSC motor on all FMU5X & FMC5X models
  • ECM motor on all FMU5Z & FMC5Z models Easy To Install Service
  • A-coil design for maximum surface area
  • Multiple electrical, refrigerant lineset and drain line entry for application flexibility
  • Primary and secondary drain connections exit from the back or side of the cabinet
  • Supports furred-down ceiling open return and ducted return applications
  • Sweat connections for long term reliability
  • Grooved aluminum tube / aluminum fin coils on FMU5X, FMC5X, FMC5Z, and FMU5Z models with AL in the 10th & 11th position
  • Item#:
    FMU5X3000AL
    Manufacturer Item:
    FMU5X3000AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • 11/2, 2, 21/2, and 3 Tons

    Upflow application only

    Accessory fieldinstalled electric heat kits available in 5, 7.5, or 10 kW

    208/230160 supply voltage

    Cabinet exterior is galvanized sheet metal

    Cabinet air leakage rate below 1.4% when tested to ASHRAE Standard 193

    Insulated for conditioned space (not to be installed in unconditioned spaces)

    All Aluminum coils

    FMA4P

    For use with R410A refrigerant utilizing standard piston

    FMA4X

    R410A refrigerant, TXV standard

    PERFORMANCE

    PSC motor on all FMA4P

    ECM motor on all FMA4X

    Motor suspended on rubber grommets for quieter operation

    Fresh air intake knockouts in cabinet

    EASY TO INSTALL AND SERVICE

    Units fits between standard stud spacings

    All service access is located in the front

    Primary and secondary drain connections exit from the bottom, access panel in bottom of cabinet

    No returnair ductwork required in specific applications

    Wall hanging brackets included with the unit
  • Item#:
    FMA5X3608AL
    Manufacturer Item:
    FMA5X3608AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    1-1/2, 2, 2-1/2, and 3 Tons
  • Upflow application only
  • Accessory field-installed electric heat kits available in 5, 7.5, or 10 kW
  • 208/230-1-60 supply voltage
  • Cabinet exterior is galvanized sheet metal
  • Cabinet air leakage rate below 1.4% when tested to ASHRAE Standard 193
  • Insulated for conditioned space (not to be installed in unconditioned spaces)
  • All Aluminum coils
  • Puron Advance refrigerant, TXV standard
  • Item#:
    FMA5L3608AL
    Manufacturer Item:
    FMA5L3608AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    MULTIFAMILY CEILING MOUNT FAN COIL
  • FMU5Z and FMC5Z 1-1/2, 2, 2-1/2, and 3 Tons
  • Horizontal application only
  • Accessory field-installed electric heat kits available in 3, 5, 6, 7.5, or 10 kW
  • 40VA, 208/230V-1-60 transformer
  • All models use Puron Advance, R-454B refrigerant and have a hard-shutoff TXV metering device
  • Adjustable condensate drain pan FM(C,U)5X, FM(C,U)5Z
  • Horizontal return applications require field fabricated bottom cover
  • Cabinets meet the requirement of 1.4% cabinet leakage rate when tested to ASHRAE Standard 193
  • Cabinets insulated to prevent cabinet sweating
  • Refrigerant lines and electrical connections can be run out the back or side of casing Performance
  • PSC motor on all FMU5X & FMC5X models
  • ECM motor on all FMU5Z & FMC5Z models Easy To Install Service
  • A-coil design for maximum surface area
  • Multiple electrical, refrigerant lineset and drain line entry for application flexibility
  • Primary and secondary drain connections exit from the back or side of the cabinet
  • Supports furred-down ceiling open return and ducted return applications
  • Sweat connections for long term reliability
  • Grooved aluminum tube / aluminum fin coils on FMU5X, FMC5X, FMC5Z, and FMU5Z models with AL in the 10th & 11th position
  • Item#:
    FMU5Z2400AL
    Manufacturer Item:
    FMU5Z2400AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • 11/2, 2, 21/2, and 3 Tons

    Upflow application only

    Accessory fieldinstalled electric heat kits available in 5, 7.5, or 10 kW

    208/230160 supply voltage

    Cabinet exterior is galvanized sheet metal

    Cabinet air leakage rate below 1.4% when tested to ASHRAE Standard 193

    Insulated for conditioned space (not to be installed in unconditioned spaces)

    All Aluminum coils

    FMA4P

    For use with R410A refrigerant utilizing standard piston

    FMA4X

    R410A refrigerant, TXV standard

    PERFORMANCE

    PSC motor on all FMA4P

    ECM motor on all FMA4X

    Motor suspended on rubber grommets for quieter operation

    Fresh air intake knockouts in cabinet

    EASY TO INSTALL AND SERVICE

    Units fits between standard stud spacings

    All service access is located in the front

    Primary and secondary drain connections exit from the bottom, access panel in bottom of cabinet

    No returnair ductwork required in specific applications

    Wall hanging brackets included with the unit
  • Item#:
    FMA5X1805AL
    Manufacturer Item:
    FMA5X1805AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Horizontal application only
    Accessory field-installed electric heat kits available in 3, 5, 6, 7.5, or 10 kW
    40VA, 208/230V-1-60 transformer
    All models use Puron Advance, R-454B refrigerant and have a hard-shutoff TXV metering device
    Adjustable condensate drain pan
    Item#:
    FMC5Z3000AL
    Manufacturer Item:
    FMC5Z3000AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    MULTIFAMILY CEILING MOUNT FAN COIL
  • FMU5Z and FMC5Z 1-1/2, 2, 2-1/2, and 3 Tons
  • Horizontal application only
  • Accessory field-installed electric heat kits available in 3, 5, 6, 7.5, or 10 kW
  • 40VA, 208/230V-1-60 transformer
  • All models use Puron Advance, R-454B refrigerant and have a hard-shutoff TXV metering device
  • Adjustable condensate drain pan FM(C,U)5X, FM(C,U)5Z
  • Horizontal return applications require field fabricated bottom cover
  • Cabinets meet the requirement of 1.4% cabinet leakage rate when tested to ASHRAE Standard 193
  • Cabinets insulated to prevent cabinet sweating
  • Refrigerant lines and electrical connections can be run out the back or side of casing Performance
  • PSC motor on all FMU5X & FMC5X models
  • ECM motor on all FMU5Z & FMC5Z models Easy To Install Service
  • A-coil design for maximum surface area
  • Multiple electrical, refrigerant lineset and drain line entry for application flexibility
  • Primary and secondary drain connections exit from the back or side of the cabinet
  • Supports furred-down ceiling open return and ducted return applications
  • Sweat connections for long term reliability
  • Grooved aluminum tube / aluminum fin coils on FMU5X, FMC5X, FMC5Z, and FMU5Z models with AL in the 10th & 11th position
  • Item#:
    FMU5Z3600AL
    Manufacturer Item:
    FMU5Z3600AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    1-1/2, 2, 2-1/2, and 3 Tons
  • Upflow application only
  • Accessory field-installed electric heat kits available in 5, 7.5, or 10 kW
  • 208/230-1-60 supply voltage
  • Cabinet exterior is galvanized sheet metal
  • Cabinet air leakage rate below 1.4% when tested to ASHRAE Standard 193
  • Insulated for conditioned space (not to be installed in unconditioned spaces)
  • All Aluminum coils
  • Puron Advance refrigerant, TXV standard
  • Item#:
    FMA5L2400AL
    Manufacturer Item:
    FMA5L2400AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • 11/2, 2, 21/2, and 3 Tons

    Upflow application only

    Accessory fieldinstalled electric heat kits available in 5, 7.5, or 10 kW

    208/230160 supply voltage

    Cabinet exterior is galvanized sheet metal

    Cabinet air leakage rate below 1.4% when tested to ASHRAE Standard 193

    Insulated for conditioned space (not to be installed in unconditioned spaces)

    All Aluminum coils

    FMA4P

    For use with R410A refrigerant utilizing standard piston

    FMA4X

    R410A refrigerant, TXV standard

    PERFORMANCE

    PSC motor on all FMA4P

    ECM motor on all FMA4X

    Motor suspended on rubber grommets for quieter operation

    Fresh air intake knockouts in cabinet

    EASY TO INSTALL AND SERVICE

    Units fits between standard stud spacings

    All service access is located in the front

    Primary and secondary drain connections exit from the bottom, access panel in bottom of cabinet

    No returnair ductwork required in specific applications

    Wall hanging brackets included with the unit
  • Item#:
    FMA5X3005AL
    Manufacturer Item:
    FMA5X3005AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS