Fujitsu Indoor Furnace cased coils and replacement
uncased coils are designed for use with Fujitsu outdoor
units and are available for vertical upflow or downflow,
and horizontal left or horizontal right airflow. When
matched with Fujitsu outdoor units, the coils provide a
nominal capacity range from 18,000 BTU/HR [5.24 kW]
to 60,000 BTU/HR [17.6 kW].
Constructed of aluminum fins bonded to internally
grooved aluminum tubing.
Coils are tested at the factory with an extensive refrigerant
leak check.
Coils have copper sweat refrigerant connections.
Feature two sets of 3/4" [14.1 mm] N.P.T. Condensate
drain connections for ease of connection.
Chatleff metering device connections, at inlet and outlet
of TXV or EEV and equalizer connections (TXV only).
Approved for system application with variety of Fujitsu
outdoor units.
Condensate drain pan is constructed of high grade, heat
resistant, corrosion free thermal-set material.
Compatible with Germicidal Light System (UV resistant)
Bi-Directional airflow eliminates the need to switch any
internal components from horizontal left to right.
Unique drain pan design maximizes application flexibility
and condensate removal.
N-Coil design maximizes performance and minimizes
height required at installation.
Coils are AHRI certified for system application with a
variety of Fujitsu outdoor units.
Constructed of aluminum fins bonded to internally grooved aluminum tubing
Features
Fujitsu Indoor Furnace cased coils and replacement
uncased coils are designed for use with Fujitsu outdoor
units and are available for vertical upflow or downflow,
and horizontal left or horizontal right airflow. When
matched with Fujitsu outdoor units, the coils provide a
nominal capacity range from 18,000 BTU/HR [5.24 kW]
to 60,000 BTU/HR [17.6 kW].
Constructed of aluminum fins bonded to internally
grooved aluminum tubing.
Coils are tested at the factory with an extensive refrigerant
leak check.
Coils have copper sweat refrigerant connections.
Feature two sets of 3/4" [14.1 mm] N.P.T. Condensate
drain connections for ease of connection.
Chatleff metering device connections, at inlet and outlet
of TXV or EEV and equalizer connections (TXV only).
Approved for system application with variety of Fujitsu
outdoor units.
Condensate drain pan is constructed of high grade, heat
resistant, corrosion free thermal-set material.
Compatible with Germicidal Light System (UV resistant)
Bi-Directional airflow eliminates the need to switch any
internal components from horizontal left to right.
Unique drain pan design maximizes application flexibility
and condensate removal.
N-Coil design maximizes performance and minimizes
height required at installation.
Coils are AHRI certified for system application with a
variety of Fujitsu outdoor units.
Industry Standard R-410A Refrigerant
Models featuring Electric Heat without Indoor Cooling Coil
Quiet and efficient X-13 (ECM) motor technology
Only 35" tall and 4-way convertible for all those tight spaces
Available from factory in upflow and horizontal configurations
Nominal airflow up to 0.5" external static pressure with reduced airflow up to 1.0" external static pressure
Factory installed MultiFlex coils
Sturdy steel construction with 1 inch [25.4 mm] of foil faced insulation for excellent sound and insulating characteristics
Permanent, easily accessible and washable filter furnished standard
Circuit breaker (standard on units with more than 11 kW) meets U.L. and cUL requirements for service disconnect
Factory installed auxiliary electric heat provides exact heat for indoor comfort over a variety of applications
Fan settings for selectable, customized cooling airflow over a wide variety of applications
Cabinet air leakage less than 2% at 1 inch H2O when tested in accordance with ASHRAE standard 193
Features
Fujitsu Indoor Furnace cased coils and replacement
uncased coils are designed for use with Fujitsu outdoor
units and are available for vertical upflow or downflow,
and horizontal left or horizontal right airflow. When
matched with Fujitsu outdoor units, the coils provide a
nominal capacity range from 18,000 BTU/HR [5.24 kW]
to 60,000 BTU/HR [17.6 kW].
Constructed of aluminum fins bonded to internally
grooved aluminum tubing.
Coils are tested at the factory with an extensive refrigerant
leak check.
Coils have copper sweat refrigerant connections.
Feature two sets of 3/4" [14.1 mm] N.P.T. Condensate
drain connections for ease of connection.
Chatleff metering device connections, at inlet and outlet
of TXV or EEV and equalizer connections (TXV only).
Approved for system application with variety of Fujitsu
outdoor units.
Condensate drain pan is constructed of high grade, heat
resistant, corrosion free thermal-set material.
Compatible with Germicidal Light System (UV resistant)
Bi-Directional airflow eliminates the need to switch any
internal components from horizontal left to right.
Unique drain pan design maximizes application flexibility
and condensate removal.
N-Coil design maximizes performance and minimizes
height required at installation.
Coils are AHRI certified for system application with a
variety of Fujitsu outdoor units.
Item#:
FCCN4921SZTA
Manufacturer Item:
FCCN4921SZTA
Manufacturer:
FUJITSU
Item#:
FF92ST307017M4SNAAS
Manufacturer Item:
FF92ST307017M4SNAAS
Manufacturer:
FUJITSU
Fujitsu FH4821TPSASN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
- 48K BTU 4 Ton
- 115/1 VAC
- 21" Wide
- PSC Motor
- Multi-Position,
FUJITSU FH4821TPSJSN
Item#:
FH4821TPSJSN
Manufacturer Item:
FH4821TPSJSN
Manufacturer:
FUJITSU
Item#:
FHSMTT6024SAZTNAN00
Manufacturer Item:
FHSMTT6024SAZTNAN00
Manufacturer:
FUJITSU
Item#:
FHRNPS4821SJZTNA
Manufacturer Item:
FHRNPS4821SJZTNA
Manufacturer:
FUJITSU
Item#:
FF70173TS92M
Manufacturer Item:
FF70173TS92M
Manufacturer:
FUJITSU
Item#:
FHRNPS4221SJZTNA
Manufacturer Item:
FHRNPS4221SJZTNA
Manufacturer:
FUJITSU