S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Features
Easily applied in upflow, horizontal left or horizontal
right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications
on B, C, and D cabinets where side discharge is not
possible.
The unit cabinet is compact and easy to install with an
ideal height of 33 in.
Full length fold-up duct connector flanges for
application flexibility.
Easy access to controls to connect power and control
wiring.
No electrical knockouts to deal with, making
installation easier.
24 V, 40 VA control transformer and control provisions
supplied for single or multi-stage add on cooling.
Built-in, high level self diagnostics with fault code
displays standard on integrated control module for
reliable operation.
Front-facing screws on flame sensor and hot surgace
ignitor for ease of service.
Front-facing screws on blower assembly for easy
access and removal of blower.
Constant torque blower motor for cooling SEER2
enhancement.
Blower-off delay for cooling SEER2 improvement
Item#:
Z9ES080C16SMPS1
Manufacturer Item:
Z9ES080C16SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Blower-off delay for cooling SEER2 improvement
Easy access to controls to connect power and control wiring
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation
Low unit current requirement for easy replacement application
All models are convertible to use propane (LP) gas.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety
Five-speed direct drive standard ECM blower motor
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling
Hi-tech tubular aluminized steel primary heat exchanger
Timed on, adjustable off blower capability for maximum comfort
Blower door safety switch
Solid removable bottom panel allows easy conversion for bottom return air applications
Low NOx models have been designed to meet specific code requirements.
Airflow leakage less than 1% of nominal airflow for duct performance testing conditions
No electrical knockouts to deal with, making installation easier
Fold-up duct connector flanges for application flexibility
Quiet inducer operation
Inducer rotates for easy conversion of venting options
Fully supported blower assembly for easy access and removal of blower
External air filters are used for maximum flexibility in meeting customers' indoor air quality
(IAQ) needs.
Venting applications: install as a common vent with other gas-fired appliances or use a lined
masonry chimney.
1/4 turn knobs are provided for easy independent door removal.
High-efficiency blower motor for lower electrical power usage and improved AC SEER2 ratings
Insulated blower compartment for thermal and acoustic performance
Item#:
Z8ES120C20SMPS1
Manufacturer Item:
Z8ES120C20SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Blower-off delay for cooling SEER2 improvement
Easy access to controls to connect power and control wiring
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation
Low unit current requirement for easy replacement application
All models are convertible to use propane (LP) gas.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety
Five-speed direct drive standard ECM blower motor
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling
Hi-tech tubular aluminized steel primary heat exchanger
Timed on, adjustable off blower capability for maximum comfort
Blower door safety switch
Solid removable bottom panel allows easy conversion for bottom return air applications
Low NOx models have been designed to meet specific code requirements.
Airflow leakage less than 1% of nominal airflow for duct performance testing conditions
No electrical knockouts to deal with, making installation easier
Fold-up duct connector flanges for application flexibility
Quiet inducer operation
Inducer rotates for easy conversion of venting options
Fully supported blower assembly for easy access and removal of blower
External air filters are used for maximum flexibility in meeting customers' indoor air quality
(IAQ) needs.
Venting applications: install as a common vent with other gas-fired appliances or use a lined
masonry chimney.
1/4 turn knobs are provided for easy independent door removal.
High-efficiency blower motor for lower electrical power usage and improved AC SEER2 ratings
Insulated blower compartment for thermal and acoustic performance
Item#:
Z8ES080C16SMPS1
Manufacturer Item:
Z8ES080C16SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Blower-off delay for cooling SEER2 improvement
Easy access to controls to connect power and control wiring
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation
Low unit current requirement for easy replacement application
All models are convertible to use propane (LP) gas.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety
Five-speed direct drive standard ECM blower motor
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling
Hi-tech tubular aluminized steel primary heat exchanger
Timed on, adjustable off blower capability for maximum comfort
Blower door safety switch
Solid removable bottom panel allows easy conversion for bottom return air applications
Low NOx models have been designed to meet specific code requirements.
Airflow leakage less than 1% of nominal airflow for duct performance testing conditions
No electrical knockouts to deal with, making installation easier
Fold-up duct connector flanges for application flexibility
Quiet inducer operation
Inducer rotates for easy conversion of venting options
Fully supported blower assembly for easy access and removal of blower
External air filters are used for maximum flexibility in meeting customers' indoor air quality
(IAQ) needs.
Venting applications: install as a common vent with other gas-fired appliances or use a lined
masonry chimney.
1/4 turn knobs are provided for easy independent door removal.
High-efficiency blower motor for lower electrical power usage and improved AC SEER2 ratings
Insulated blower compartment for thermal and acoustic performance
Item#:
Z8ES100C16SMPS1
Manufacturer Item:
Z8ES100C16SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal
conversion necessary
The unit cabinet is compact and easy to install with an ideal height of 33 in.
Blower-off delay for cooling SEER2 improvement
Easy access to controls to connect power and control wiring
Built-in, high level self diagnostics with fault code displays standard on integrated control
module for reliable operation
Low unit current requirement for easy replacement application
All models are convertible to use propane (LP) gas.
Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
100% shut-off main gas valve for extra safety
Five-speed direct drive standard ECM blower motor
24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on
cooling
Hi-tech tubular aluminized steel primary heat exchanger
Timed on, adjustable off blower capability for maximum comfort
Blower door safety switch
Solid removable bottom panel allows easy conversion for bottom return air applications
Low NOx models have been designed to meet specific code requirements.
Airflow leakage less than 1% of nominal airflow for duct performance testing conditions
No electrical knockouts to deal with, making installation easier
Fold-up duct connector flanges for application flexibility
Quiet inducer operation
Inducer rotates for easy conversion of venting options
Fully supported blower assembly for easy access and removal of blower
External air filters are used for maximum flexibility in meeting customers' indoor air quality
(IAQ) needs.
Venting applications: install as a common vent with other gas-fired appliances or use a lined
masonry chimney.
1/4 turn knobs are provided for easy independent door removal.
High-efficiency blower motor for lower electrical power usage and improved AC SEER2 ratings
Insulated blower compartment for thermal and acoustic performance
Item#:
Z8ES100B12SMPS1
Manufacturer Item:
Z8ES100B12SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal
right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications
on B, C, and D cabinets where side discharge is not
possible.
The unit cabinet is compact and easy to install with an
ideal height of 33 in.
Full length fold-up duct connector flanges for
application flexibility.
Easy access to controls to connect power and control
wiring.
No electrical knockouts to deal with, making
installation easier.
24 V, 40 VA control transformer and control provisions
supplied for single or multi-stage add on cooling.
Built-in, high level self diagnostics with fault code
displays standard on integrated control module for
reliable operation.
Front-facing screws on flame sensor and hot surgace
ignitor for ease of service.
Front-facing screws on blower assembly for easy
access and removal of blower.
Constant torque blower motor for cooling SEER2
enhancement.
Blower-off delay for cooling SEER2 improvement
Item#:
Z9ES040A10SMPS1
Manufacturer Item:
Z9ES040A10SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Features
Easily applied in upflow, horizontal left or horizontal
right, or downflow installation with minimal
conversion necessary.
Venting kit for downflow (counter-flow) applications
on B, C, and D cabinets where side discharge is not
possible.
The unit cabinet is compact and easy to install with an
ideal height of 33 in.
Full length fold-up duct connector flanges for
application flexibility.
Easy access to controls to connect power and control
wiring.
No electrical knockouts to deal with, making
installation easier.
24 V, 40 VA control transformer and control provisions
supplied for single or multi-stage add on cooling.
Built-in, high level self diagnostics with fault code
displays standard on integrated control module for
reliable operation.
Front-facing screws on flame sensor and hot surgace
ignitor for ease of service.
Front-facing screws on blower assembly for easy
access and removal of blower.
Constant torque blower motor for cooling SEER2
enhancement.
Blower-off delay for cooling SEER2 improvement
Item#:
Z9ES060B12SMPS1
Manufacturer Item:
Z9ES060B12SMPS1
Manufacturer:
BHC RESIDENTIAL AND LIGHT COMM
Unique Manufactured Housing Design with a
robust, 19 7/8"W, fully-insulated cabinet to fit the
standard MH footprint. The MG2R is our flagship
high-efficiency, HUD-compliant, gas furnace.
AC-Ready 4-Ton ECM Blower with 5-speed taps,
with/without a factory-installed 20"H coil box;
allowing for a field-installed 20"/26"H coil box to
suit your capacity and access needs. Refer to Split
System sell sheets for AHRI-rated coil-fit matches.
Quick LP Conversion with an easy-access gas valve
regulator and manifold, using the factory-provided
LP orifices included in the unit-literature kit.
Category IV Venting Approval allows for vertical
or horizontal direct venting using an approved
non-metallic two-pipe system, or a concentric
termination kit for application flexibility.
Dependable Warranty and Support, handled
directly by Style Crests dedicated HVAC Team,
offering the most competitive warranty coverage
and service in the Manufactured Housing Industry.
Nortek Global (Intertherm) MG2S045F2ABM1
Item#:
MG2S045F2ABM1
Manufacturer Item:
MG2S-045F2ABM1
Manufacturer:
NORTEK GLOBAL (INTERTHERM)
l
International Comfort Products G80CTL1352422B
Item#:
G80CTL1352422B
Manufacturer Item:
G80CTL1352422B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
Armstrong Air Conditioning 2-Stage Variable Speed Gas Furnace, 95% AFUE, 120 VAC, 44,000 BTU, 1200 cfm
,
- Aluminized steel design primary heat exchanger with crimped non welded construction
- AL 29-4C stainless steel secondary heat exchanger, non-welded crimped S-curve primary heat exchanger design for maximum durability
- Aluminized steel in shot burners for smooth ignition, isolated burner enclosure for quiet operation
- Standardized widths for easy coil fit, unitized construction for cabinet integrity
- Heat exchanger compartment is insulated to increase efficiency and reduce sound levels
- Efficient ECM variable speed blower motor
- Motor features soft start and soft stop for quiet operation
- Active and passive dehumidification feature
- Easily removable slide out blower design
- Dynamically balanced blower wheel with resilient motor mounts for smooth and quiet operation
- 2-speed induced draft motor with stainless steel shaft, steel ball bearings and fan cooled for long life
- Direct vent refers to a combustion air supply intake pipe installed in conjunction with flue gas vent pipe
- Integrated ignition and fan control
- System sentry control retains last 5-fault codes with push butTon memory recall, regardless of power interruption
- Hot surface ignition system uses silicon nitride igniter
- Control circuit is fuse protected
- 2-stage thermostat is recommended when installed with 2-stage cooling unit
- Left or right gas and electric entry
- Certified for direct vent (2-pipe) or non-direct (1-pipe) applications
- 10 years limited parts warranty
,
Armstrong Air Conditioning 67W68
Item#:
67W68
Manufacturer Item:
95G2UH045BV12
Manufacturer:
ALLIED AIR ENTERPRISES
The Thermo Pride story - located right here in the United States, Thermo Products, makers of Thermo Pride heating and cooling equipment, is known for superior workmanship and product innovation. Thermo Products is committed to producing handcrafted products that provide your family with reliability, comfort, durability, quiet operation and high efficiency. You will have the peace-of-mind that comes from knowing your gas Thermo Pride mobile home furnace is anything but a mass-produced, low-cost compromise between quality and price. Reliability - whether you are upgrading to save energy or your current furnace has failed, you will want to replace it with one that is both dependable and economical. Thermo Pride mobile home furnaces are designed and built specifically as replacement furnaces, so you can easily upgrade the heating or cooling system in your home.
- Integrated coil cabinet for easy air conditioning installation
- Aluminized steel primary heat exchanger
- Stainless steel secondary heat exchanger
- Silicon nitride igniter for quiet and consistent light-off
- 2-piece top design for easy access to vent pipes
- Concentric vent kit available using existing roof jack and standard base
- PVC venting
- Lifetime heat exchanger warranty and 10 years parts warranty
Thermo Pride CLQS1-100T48N
Item#:
CLQS1-100T48N
Manufacturer Item:
CLQS1-100T48N
Manufacturer:
THERMO PRODUCTS, LLC
International Comfort Products F97CMN1202422B
Item#:
F97CMN1202422B
Manufacturer Item:
F97CMN1202422B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
