|◀ 505 - 516 of 627 ▶|
View:
Resideo R7284B1024 Oil Burner Primary Control 15 Second Lockout Timing Interrupted Ignition

Resideo R7284B1024

Item#:
R7284B1024
Manufacturer Item:
R7284B1024
Manufacturer:
HONEYWELL
Resideo R8239A1052 Fan Control Center Relay, 120 VAC, 26.5 volt Secondary, SPDT
    NEMA standard type"D" transformer (included) powers 24 VAC control systems
  • Provides overload protection for transformer
  • Convenient connections for thermostat and heating and cooling equipment wiring
  • Mounts on standard 4 x 4" junction box
  • Can be mounted in any indoor location without additional enclosure
  • Relay is easily replaced without disturbing wiring
  • Includes R8222B relay and enclosure
  • Inrush - 20 VA maximum, 17 VA nominal, sealed - 10 VA maximum, 9 VA nominal
  • NEMA Standard DC20-1992

    HONEYWELL R540-135

Item#:
R540-135
Manufacturer Item:
R8239A1052
Manufacturer:
HONEYWELL
Honeywell R80-40 High Limit Immersion Aquastat Control 110-220 Degrees Low/130-240 Degrees,

Honeywell R80-40

Item#:
R80-40
Manufacturer Item:
R8182H1070
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184G4066/U Non-Recycle Oil Burner Control with Safety Timing, 4-1/8" W x 4-3/8" H x 2-1/2" Depth
    Provides automatic, non-recycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 volts thermostat required
  • 15 second safety timing, alarm outputs, and manual safety switch
  • Intermittent ignition timing

    honeywell r75-37

Item#:
R75-37
Manufacturer Item:
R8184G4066
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184G4082 Oil Burner Control
    With 45 sec safety timing and alarm outputs
  • Provides automatic, nonrecycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)

    honeywell r75-44

Item#:
R75-44
Manufacturer Item:
R8184G4082
Manufacturer:
HONEYWELL
Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 volt
    Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • With 15 sec safety timing, alarm outputs and manual safety switch
Sid Harvey Item #:R75-40: Replaces Part #:'s : R75-39R | R75-40R | ICM150

R75-40

Item#:
R75-40
Manufacturer Item:
R8184G4009
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184M1051 Oil Burner Control for Boilers, 120 - 240 VAC
    Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
  • Intermittent ignition is on while the burner is on
  • Solid state flame sensing circuit
  • External button to manually reset safety switch after lockout
  • Enclosed safety switch must be manually reset after safety shutdown
  • R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required

    honeywell r75-58

Item#:
R75-58
Manufacturer Item:
R8184M1051
Manufacturer:
HONEYWELL
Resideo R7284U1004 Oil Burner Primary Control 15/30/45 Second Lockout Timing

honeywell r7284u1004

Item#:
R7284U1004
Manufacturer Item:
R7284U1004
Manufacturer:
HONEYWELL
Honeywell 120320 Cad Cell Eye for Use with Oil Primary Control in Burner

honeywell r82-1

Item#:
R82-1
Manufacturer Item:
120320/U
Manufacturer:
HONEYWELL
Bramec Corporation and is a major distributor in the Electrical, Plumbing, Hardware and HVAC/R industry
  • SLURK24V Hot Surface Ignitor Tip 2-1/2" Buss Bar

    bramec slurk24v

  • Item#:
    SLURK24V
    Manufacturer Item:
    SLURK24V
    Manufacturer:
    HONEYWELL
    Resideo SV9602P4816 Smart Valve Gas Valve Hot surface Intermittent Step opening 24 VAC 3/4" x 3/4"

    Resideo SV9602P4816

    Item#:
    SV9602P4816
    Manufacturer Item:
    SV9602P4816
    Manufacturer:
    HONEYWELL
    Resideo SV9602P4824 Hot Surface Gas Valve 3/4" 24 VAC,

    SV9602P4824

    Item#:
    SV9602P4824
    Manufacturer Item:
    SV9602P4824
    Manufacturer:
    HONEYWELL
    |◀ 505 - 516 of 627 ▶|