S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Resideo Q390A1103 Thermocouple 11/32-32 Male Nut 48" L Lead 25-35 MV Output
Resideo Q390A1103
Resideo Q314U1001 Universal Pilot Burner for Q309 Q340 Q390 Thermocouples
Resideo Q314U1001
Resideo R7284B1024 Oil Burner Primary Control 15 Second Lockout Timing Interrupted Ignition
Resideo R7284B1024
Resideo R8239A1052 Fan Control Center Relay, 120 VAC, 26.5 volt Secondary, SPDT
- NEMA standard type"D" transformer (included) powers 24 VAC control systems
- Provides overload protection for transformer
- Convenient connections for thermostat and heating and cooling equipment wiring
- Mounts on standard 4 x 4" junction box
- Can be mounted in any indoor location without additional enclosure
- Relay is easily replaced without disturbing wiring
- Includes R8222B relay and enclosure
- Inrush - 20 VA maximum, 17 VA nominal, sealed - 10 VA maximum, 9 VA nominal
- NEMA Standard DC20-1992
HONEYWELL R540-135
Honeywell Protectorelay R8184G4066/U Non-Recycle Oil Burner Control with Safety Timing, 4-1/8" W x 4-3/8" H x 2-1/2" Depth
- Provides automatic, non-recycling control of an intermittent ignition oil burner system
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
- C554A cadmium sulfide flame detector and 24 volts thermostat required
- 15 second safety timing, alarm outputs, and manual safety switch
- Intermittent ignition timing
honeywell r75-37
Honeywell Protectorelay R8184G4082 Oil Burner Control
- With 45 sec safety timing and alarm outputs
- Provides automatic, nonrecycling control of an intermittent ignition oil burner system
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)
honeywell r75-44
Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 volt
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 15 sec safety timing, alarm outputs and manual safety switch
R75-40
Item#:
R75-40
Manufacturer Item:
R8184G4009
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184M1051 Oil Burner Control for Boilers, 120 - 240 VAC
- Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
- Intermittent ignition is on while the burner is on
- Solid state flame sensing circuit
- External button to manually reset safety switch after lockout
- Enclosed safety switch must be manually reset after safety shutdown
- R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
honeywell r75-58
Resideo R7284U1004 Oil Burner Primary Control 15/30/45 Second Lockout Timing
honeywell r7284u1004
Item#:
R7284U1004
Manufacturer Item:
R7284U1004
Manufacturer:
HONEYWELL
Honeywell R80-40 High Limit Immersion Aquastat Control 110-220 Degrees Low/130-240 Degrees,
Honeywell R80-40
Honeywell 120320 Cad Cell Eye for Use with Oil Primary Control in Burner
honeywell r82-1
Item#:
R82-1
Manufacturer Item:
120320/U
Manufacturer:
HONEYWELL
Bramec Corporation and is a major distributor in the Electrical, Plumbing, Hardware and HVAC/R industry
SLURK24V Hot Surface Ignitor Tip 2-1/2" Buss Bar
bramec slurk24v
Item#:
SLURK24V
Manufacturer Item:
SLURK24V
Manufacturer: