Honeywell Protectorelay R8184G4082 Oil Burner Control
  • With 45 sec safety timing and alarm outputs
  • Provides automatic, nonrecycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • Enclosed safety switch with External reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)
Sid Harvey Item #:R75-44: Replaces Part #:'s : L40-026,
,

Honeywell R75-44

Item#:
R75-44
Manufacturer Item:
R8184G4082
Manufacturer:
HONEYWELL
Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 volt
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with External reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • With 15 sec safety timing, alarm outputs and manual safety switch
Sid Harvey Item #:R75-40: Replaces Part #:'s : R75-39R | R75-40R | ICM150,
,

Honeywell R75-40

Item#:
R75-40
Manufacturer Item:
R8184G4009
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184M1051 Oil Burner Control for Boilers, 120 - 240 VAC
  • Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
  • Intermittent ignition is on while the burner is on
  • Solid state flame sensing circuit
  • External button to manually reset safety switch after lockout
  • Enclosed safety switch must be manually reset after safety shutdown
  • R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
Sid Harvey Item #:R75-58: Replaces Part #:'s : R75-58R,

,

Honeywell R75-58

Item#:
R75-58
Manufacturer Item:
R8184M1051
Manufacturer:
HONEYWELL
Resideo R7284U1004 Oil Burner Primary Control 15/30/45 Second Lockout Timing,

Resideo R7284U1004

Item#:
R7284U1004
Manufacturer Item:
R7284U1004
Manufacturer:
HONEYWELL
Honeywell 120320 Cad Cell Eye for Use with Oil Primary Control in Burner
,
,

Honeywell R82-1

Item#:
R82-1
Manufacturer Item:
120320/U
Manufacturer:
HONEYWELL
Bramec Corporation and is a major distributor in the Electrical, Plumbing, Hardware and HVAC/R industry
  • SLURK24V Hot Surface Ignitor Tip 2-1/2" Buss Bar,
    ,

    Bramec SLURK24V

  • Item#:
    SLURK24V
    Manufacturer Item:
    SLURK24V
    Manufacturer:
    HONEYWELL
    Item#:
    SPRD08
    Resideo SV9602P4816 Smart Valve Gas Valve Hot surface Intermittent Step opening 24 VAC 3/4" x 3/4",

    Resideo SV9602P4816

    Item#:
    SV9602P4816
    Manufacturer Item:
    SV9602P4816
    Manufacturer:
    HONEYWELL
    Resideo SV9602P4824 Hot Surface Gas Valve 3/4" 24 VAC,
    ,

    Resideo SV9602P4824

    Item#:
    SV9602P4824
    Manufacturer Item:
    SV9602P4824
    Manufacturer:
    HONEYWELL
    Resideo SV9601M4571 Smart Valve Gas Valve Hot surface Intermittent 24 VAC 3/4" x 3/4",

    Resideo SV9601M4571

    Item#:
    SV9601M4571
    Manufacturer Item:
    SV9601M4571
    Manufacturer:
    HONEYWELL
    Item#:
    SV9602P4832
    Resideo SV9502H2522 Smart Valve Gas Valve Intermittent & Hot surface 24 VAC 1/2" x 1/2" Continuous Retry,

    Resideo SV9502H2522

    Item#:
    SV9502H2522
    Manufacturer Item:
    SV9502H2522
    Manufacturer:
    HONEYWELL