|◀ 421 - 432 of 627 ▶|
View:
Resideo CHWES41013/U White Cable Sensor, 4 feet Probe
    Conveniently place near sinks, washers, water heaters, sump pumpsanywhere leaks could happen. Battery life lasts up to 3 years without incident
  • Notification messages can alert you or your family/ friends, wherever you are, while audible (100 dB alarm) alerts sound when you are at home
  • Use to detect temperatures that can freeze pipes, and humidity that could damage valuables
  • Runs on WiFi - No Extra Hub or hardware purchase required
  • Daisy chain extra cable sensors and cover up to 500 feet of space with one leak detector
  • Reusable even after detecting an incident
  • After an alarm, simply wipe dry the detector and cable sensors and place them back into service
  • There is a 5 years warranty for professionally installed devices
  • Mounting - Insert the plug from the cable sensor into the cable sensor jack at the end of the previous cable sensor, repeat for additional cable sensors up to a limit of 500 feet of cable sensors

    HONEYWELL CHWES41013

Item#:
CHWES41013
Manufacturer Item:
CHWES41013
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
    Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
  • Visible control point scale and external adjustments screw permit easy setting
  • Horizontal insertion of the sensing element
  • Direct/well immersion of the sensing element
  • Remote buLbs. model may be used to sense air temperature in ducts and in outside air sensing applications
  • Contacts break on temperature rise
  • Screw terminals wiring
  • Includes heat-conductive compound

    Honeywell C290

Item#:
C290
Manufacturer Item:
L4006A1678
Manufacturer:
HONEYWELL
Honeywell C292 Aquastat Remote BuLbs. 5' Capillary SPST Break On Rise 100-240 Degrees,

Honeywell C292

Item#:
C292
Manufacturer Item:
L4008A1015
Manufacturer:
HONEYWELL
Honeywell L4081B1096/U High Limit Circulator Aquastat Control, 110 - 220 deg F Low, 130 - 240 deg F High
    An immersion type liquid-filled sensing element actuates (2) snap switches
  • (1) switch operates as a high limit control
  • The other switch operates as a low limit and/or circulator control, depending on the model
  • Controller may be mounted in any positioning and needs no leveling
  • Separate, easy-to-read, calibrated dial and setpoint adjustments for each switch
  • Differential adjustment on low limit or circulator switch on select models
  • All adjustments accessible inside front cover
  • Push-in terminals for quick connecting
  • 1-sensing element for easy installation
  • (2) SPST snap switches act independently at respective temperature settings
  • 3" insulation depth
  • 360 VA transformer load ignition electrical ratings
  • High limit, low limit and/or circulator controllers used to regulate boiler water temperature in gas- or oil-fired hydronic heating systems

    Honeywell C322-4A

Item#:
C322-4A
Manufacturer Item:
L4081B1096
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
  • Totally enclosed micro switch snap-acting switches operate on temperature rise to setpoint
  • Visible control point scale and external adjustments screw permit easy setting
  • Horizontal or vertical insertion of the sensing element
  • Remote buLbs. model may be used to sense air temperature in ducts and in outside air sensing applications
  • Direct or well immersion of the sensing element
  • Includes heat-conductive compound, well adapter Honeywell L4006E1067 High Limit Manual Reset Aquastat, 130 - 270 deg F, 10 - 25 deg F Differential

    Honeywell C290-6

Item#:
C290-6
Manufacturer Item:
L4006E1067
Manufacturer:
HONEYWELL
Resideo C335-2 Aquastat Strap-On SPDT 65-200 Degrees,

Resideo C335-2

Item#:
C335-2
Manufacturer Item:
L6006C1018
Manufacturer:
HONEYWELL
Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
  • Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
  • High limit opens burner circuit only
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • 1-1/2 - 3" depth less well insulation
  • Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
  • Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential

    Honeywell C312-9

Item#:
C312-9
Manufacturer Item:
L8148J1009
Manufacturer:
HONEYWELL
The L8148 Aquastat Relays are immersion type hydronic controllers that combine high limit protection with switching relay control of burner and circulator motors.

Honeywell C312-8

Item#:
C312-8
Manufacturer Item:
L8148A1017
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
    Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
  • Visible control point scale and external adjustments screw permit easy setting
  • Horizontal insertion of the sensing element
  • Direct/well immersion of the sensing element
  • Remote buLbs. model may be used to sense air temperature in ducts and in outside air sensing applications
  • Contacts make on temperature rise
  • Screw terminals wiring

    Honeywell C290-1A

Item#:
C290-1A
Manufacturer Item:
L4006B1163
Manufacturer:
HONEYWELL
Resideo C322-4 Dual Aquastat Relay High limit Circulator,

HONEYWELL C322-4

Item#:
C322-4
Manufacturer Item:
L4081B1047
Manufacturer:
HONEYWELL
Resideo C345-2 Temperature Control 55-175 Degrees 5' Capillary,

Honeywell C345-2

Item#:
C345-2
Manufacturer Item:
T675A1540
Manufacturer:
HONEYWELL
Honeywell L8124C1003 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
    Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC line voltage; at locked rotor: 44.4 amp at 120 VAC, 22.7 amp at 240 VAC line voltage
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
  • 1-1/2" depth insulation

    Honeywell C317-5

Item#:
C317-5
Manufacturer Item:
L8124C1003
Manufacturer:
HONEYWELL
|◀ 421 - 432 of 627 ▶|
View: