S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Bock Parts 15110 Anode Rod 3/4" x 30", 32E ,
Item#:
15110
Manufacturer Item:
15110
Manufacturer:
BOCK WATER HEATERS
Bock Parts 15120-01 Anode Rod 3/4" x 36" 51E
Bock Parts 15120-01
Bock Parts 15120-01
Item#:
15120-01
Manufacturer Item:
15120
Manufacturer:
BOCK WATER HEATERS
Reznor Heating Parts 196949 Limit Switch 225 Degrees (Reznor)
Item#:
196949
Manufacturer Item:
196949
Manufacturer:
REZNOR LLC
Reznor Parts 195265 DSI Control Board,
Item#:
195265
Manufacturer Item:
195265
Manufacturer:
REZNOR LLC
Parker Valve Gasket Kit A8A, A81, SPORT 3 to 11
Multi-function micro-processor circuit board with these standard features:
Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air
handler
Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after
thermostat is satisfied, for increased efficiency
120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied
motorized zone valves
Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
Manual Air Vent on hot water coil
Blower door shut-off switch (except 60/61HCXW (PSC))
Slide out hot water coil for easier service
Copper tube heating and cooling coils
Compatible with all major brands of split condensing units and heat pumps
Attractive baked-on powder coated cabinet
Primary and secondary condensate drain connections
Easily accessible 1 filter
Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
Item#:
24HCXW2V10AVB00AAF
Manufacturer Item:
6024W2V10AVB00AAF
Manufacturer:
FIRST CO.
Larrs Heating Parts 2400-526 Ignitor,
larrs heating parts 2400-526
larrs heating parts 2400-526
Item#:
2400-526
Manufacturer Item:
2400-526
Manufacturer:
LAARS HEATING SYSTEM CO
Multi-function micro-processor circuit board with these standard features:
Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air
handler
Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after
thermostat is satisfied, for increased efficiency
120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied
motorized zone valves
Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
Manual Air Vent on hot water coil
Blower door shut-off switch (except 60/61HCXW (PSC))
Slide out hot water coil for easier service
Copper tube heating and cooling coils
Compatible with all major brands of split condensing units and heat pumps
Attractive baked-on powder coated cabinet
Primary and secondary condensate drain connections
Easily accessible 1 filter
Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
Item#:
24HCXW2010AVB00AAF
Manufacturer Item:
6024W2010AVB00AAF
Manufacturer:
FIRST CO.
Altherm 21790 Temperature and Pressure Relief Valve
- 3/4"
- 51E
- 150 psi,
Item#:
21790
Manufacturer Item:
21790
Manufacturer:
BOCK WATER HEATERS
Amtrol Parts Hydromax Thermostat Mechanical Aquastat Control
24 or 120 VAC capability
Diagnostic error codes to assist in troubleshooting
Built-in relays w/replaceable fuses
Intelligent "Memory Save" feature that eliminates post-outage resets
Low-voltage capability to guard against shutdown during brownout conditions
Color-coded and clearly labeled wire leads for ease of installation
First Company 30HBXB-HW Baked-On Powder-Coated Variable Speed Hydronic Air Handler with TXV Metering Device R410A, 30000 BTU Cooling, 58900 BTU Heating, 2.5 Ton, 120 VAC
,
- Multi-function micro-processor circuit board
- Blower start relay - eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
- Manual air vent on hot water coil
- Blower door shut-off switch
- Slide-out hot water coil for easier service
- 2-speed fan operation
- Convertible horizontal drain pan
- PisTon type metering device (standard)
- Copper tube heating and cooling coils
- Compatible with all major brands of split condensing units and heat pumps
- Primary and secondary condensate drain connections
- Factory installed filter drier
- 1" filter easily accessible
- Without pump
,
Item#:
30HBXB-HW-TXV410
Manufacturer Item:
30HBXB-HW-TXV410
Manufacturer:
FIRST CO.
Multi-function micro-processor circuit board with these standard features:
Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air
handler
Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after
thermostat is satisfied, for increased efficiency
120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied
motorized zone valves
Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
Manual Air Vent on hot water coil
Blower door shut-off switch (except 60/61HCXW (PSC))
Slide out hot water coil for easier service
Copper tube heating and cooling coils
Compatible with all major brands of split condensing units and heat pumps
Attractive baked-on powder coated cabinet
Primary and secondary condensate drain connections
Easily accessible 1 filter
Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
Item#:
30HCXW2010AVB00AAF
Manufacturer Item:
6030W2010AVB00AAF
Manufacturer:
FIRST CO.