S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Sid Harvey B163-92R Thrush Power Head Zone Valve REMANUFACTURED,
Item#:
B163-92R
Manufacturer Item:
B163-92R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124C High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-5R
Manufacturer Item:
L8124C1003
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124L High Limit Triple Aquastat Relay, 24 - 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-11R
Manufacturer Item:
L8124L1011
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-73R Heat Timer EPU-CH Blue Panel REMANUFACTURED,
Item#:
C346-73R
Manufacturer Item:
C346-73R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-72R Heat Timer EPU Blue Panel REMANUFACTURED,
Item#:
C346-72R
Manufacturer Item:
C346-72R
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124E High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
Mount directly to boiler - Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-7R
Manufacturer Item:
L8124E1016
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey L8151A is a remote bulb controller for use with hydronic heating systems that include domestic hot water service.
- Provides high limit, low limit and circulator control for maintaining boiler temperatures
- Can provide multizone control by using a separate thermostat and R845 Relay for each zone
- An internal transformer powers the thermostat circuit
- Shielded capillary allows convenient mounting
- Consists of a diaphragm powerhead and micro switch assembly that responds to temperature changes in the boiler water
- Mounting lugs on back of case
Item#:
C317-13R
Manufacturer Item:
L8151A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C317R Triple Aquastat, 110 - 220 deg F Low Limit, 130 - 240 deg F High Limit, 10 - 25 deg F Adjustable Low Limit, 10 deg F Fixed High Limit Differential, SPST, 120 VAC, Remanufactured
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water
- Provides multi zone control by using a separate circulator and relay for each zone
- Includes diaphragm power head and Micro-Switch assembly that respond to temperature changes in boiler water
- Mounts directly to boiler
- Requires a 24 VAC thermostat with heat anticipator set at 0.2 ampSid Harvey Item #:C317R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317-2R,
Item#:
C317R
Manufacturer Item:
L8024A
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
Sid Harvey C290R Aquastat, 100 - 240 deg F, 5 - 30 deg F Mid-ScaleSid Harvey Item #:C290R: Replaces Part #:'s : AQU4006A1678-C290 | AQU4006A2007-C290A | C290 | C290A |,
Item#:
C290R
Manufacturer Item:
L4006A1678-2007
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C354-1R Pressuretrol Controller, SPST, 0.5-9 psi Adjustable, 3-3/8" W x 4-15/32" H x 2-1/4" D, Remanufactured
- The PA404 is a series 40 (2-wire, SPST) pressuretrol controller for use in 24, 120, 240 or 277 volt control circuits or in self powered (millivoltage) applications
- The PA404B is used with suspension-type unit heaters to make the fan circuit when a pressure rise indicates the presence of steam
- Each model contains an SPST micro-switch snap-acting switch
- Sensitive pressure-actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism which operates the snap switch
- A screw on top of the case allows set point adjustment without removing the cover
- Differential is adjusted by means of a dial located inside the case
- Recommended minimum set point is differential setting plus 1-1/2 psi
- Tradeline value
- Stainless steel diaphragm sensor element
- Additive or subtractive differential type
- Makes at set point plus differential on pressure rise, breaks at set point on pressure fall
- 50 psi pressure surge
- 0.5-9 psi adjustable scale range,
Item#:
C354-1R
Manufacturer Item:
PA404B1023
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C346-58R Discharge Water Control, 80 - 220 deg F, 24/120/240,
Item#:
C346-70R
Manufacturer Item:
C346-70R
Manufacturer:
SID HARVEY REMANUFACTURED