Sid Harvey Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
  • Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
  • High limit opens burner circuit only
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • 1-1/2 - 3 Inch depth less well insulation
  • Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
  • Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential,
    ,

    Sid Harvey Remanufactured C312-9R

Item#:
C312-9R
Manufacturer Item:
L8148J1009
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C293-3R Aquastat Immersion SPDT 100-240 Degrees REMANUFACTURED,
,

Sid Harvey Remanufactured C293-3R

Item#:
C293-3R
Manufacturer Item:
L6006A1145
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124C High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-5R: Replaces Part #:'s : C317-5R,
,

Sid Harvey Remanufactured C317-5R

Item#:
C317-5R
Manufacturer Item:
L8124C1003
Manufacturer:
SID HARVEY REMANUFACTURED
Sealed Unit Parts Camstat L593BA Limit Control Switch, SPDT, 120 - 250 deg F Adjustable, 30 deg F Differential, 120/240 VAC
  • User adjustable temperature setting
Sid Harvey Item #:C375-75: Replaces Part #:'s : L36-138,
,

Sealed Unit Parts C375-75

Item#:
C375-75
Manufacturer Item:
L593BA
Manufacturer:
SEALED UNIT PARTS CO, INC
Sid Harvey Remanufactured C346-73R Heat Timer EPU-CH Blue Panel REMANUFACTURED,
,

Sid Harvey Remanufactured C346-73R

Item#:
C346-73R
Manufacturer Item:
C346-73R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-72R Heat Timer EPU Blue Panel REMANUFACTURED,
,

Sid Harvey Remanufactured C346-72R

Item#:
C346-72R
Manufacturer Item:
C346-72R
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124E High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-7R: Replaces Part #:'s : C317-7

Sid Harvey Remanufactured C317-7R

Item#:
C317-7R
Manufacturer Item:
L8124E1016
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C317R Triple Aquastat, 110 - 220 deg F Low Limit, 130 - 240 deg F High Limit, 10 - 25 deg F Adjustable Low Limit, 10 deg F Fixed High Limit Differential, SPST, 120 VAC, Remanufactured
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water
  • Provides multi zone control by using a separate circulator and relay for each zone
  • Includes diaphragm power head and Micro-Switch assembly that respond to temperature changes in boiler water
  • Mounts directly to boiler
  • Requires a 24 VAC thermostat with heat anticipator set at 0.2 ampSid Harvey Item #:C317R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317-2R,
    ,

    Sid Harvey Remanufactured C317R

Item#:
C317R
Manufacturer Item:
L8024A
Manufacturer:
SID HARVEY REMANUFACTURED
Sealed Unit Parts Camstat F558 Universal Fan and Limit Control
  • Combination fan and limit control
  • Universal replacement in forced air heating furnaces
  • Adjustable fan off setting
  • Adjustable differential setting
  • Adjustable furnace temperature limit to match existing setting
  • 40 VA at 30 deg F and 120 deg F pilot duty
Sid Harvey Item #:C450: Replaces Part #:'s : FAL3C-05TD-120A | FAL3C05TD120A |,
,

Sealed Unit Parts C450

Item#:
C450
Manufacturer Item:
F558
Manufacturer:
SEALED UNIT PARTS CO, INC
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor

Sid Harvey Remanufactured C317-8R

Item#:
C317-8R
Manufacturer Item:
L8124G1020
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C346-58R Discharge Water Control, 80 - 220 deg F, 24/120/240,
,

Sid Harvey Remanufactured C346-70R

Item#:
C346-70R
Manufacturer Item:
C346-70R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290R Aquastat, 100 - 240 deg F, 5 - 30 deg F Mid-Scale,
,

Sid Harvey Remanufactured C332-6R

Item#:
C332-6R
Manufacturer Item:
L6081A1010
Manufacturer:
SID HARVEY REMANUFACTURED