S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Brand Name
Part Type
White Rodgers Cooling Controls 50D50-843 Universal Intermittent Pilot Spark Ignition Module for Gas-Fired Non-Integrated Forced Air Furnaces, 25 VAC, 0.2 amp, 4.13" W x 4.13" H x 1-1/2" D
- Color LED indicator for diagnostics
- Includes program keys, double-sided foam back tape, color coded timing label, pre-printed hanging carTon
- 1/4 and 3/16" quick connect terminals
- Direct and indirect flame senseSid Harvey Item #:50D50-843: Replaces Part #:'s : CSA35A-617R | CSA35A-618R | CSA42A-600R | CSA42A-601R | CSA42A-602R | CSA42A-603R | CSA42A-604R | CSA43A-600R | CSA44A-600R | CSA45A-601R | CSA45A-602R | CSA46A-600R | CSA48A-600R | CSA49A-600R | CSA49A-605R | CSA51A-601R | CSA52A-600R
White Rodgers 50D50-843
Item#:
50D50-843
Manufacturer Item:
50D50-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56-743 Hot Surface Igniter Nitride Integrated Furnace Control, 25 VAC, 0.45 amp, 50/60 Hz
- System diagnostic LED with fault recall
- Multi speed circulator
- 1 or 2-stage gas valve
- Relay load ratings - 1.5 amp at 25 VAC 50/60 Hz 0.6 pico-F valve relay, 6 amp at 120 VAC 50/60 Hz (resistive) igniter relay, 2.2 amp full load, 3.5 amp locked rotor at 120 VAC inducer relay, 14.5 amp full load, 25 amp locked rotor at 120 VAC circulator relay
- Flame current requirements - 1 micro-amp DC minimum current to insure flame detection, 0.10 micro-amp DC maximum current for non-detection, 100 mega-ohm maximum allowable leakage resistance
- 0.8 sec flame establishing time, 2 sec flame failure response time
White Rodgers 50M56-743
Item#:
50M56-743
Manufacturer Item:
50M56-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
The 50A66-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.
- 3-fan speeds
- Remote flame sensing
- Humidifier and electronic air cleaner connections (optional)
- 1.5 amp valve relay
- 6 amp igniter relay
- 2.2 amp full load - 3.5 amp locked rotor inducer relay
- 14.5 amp full load - 25 amp locked rotor circulator relay
- Diagnostic indicator flash codes, controls gas valve, igniter, blower, inducer, humidifier and air cleaner
White Rodgers 50A66-743
Item#:
50A66-743
Manufacturer Item:
50A66-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50D50-801 Pilot Spark Ignition Control for Gas Appliance 18-30 VAC 0.2 amp
White Rodgers 50D50-801
Item#:
50D50-801
Manufacturer Item:
30W33
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 5059-134 Pilot Relite Control, 24 VAC, 0.03 amp
- Generates spark pulse until flame is sensed through spark electrode
- Begins sparking immediately if flame extinguishes
- Rugged solid state module design
- Spike terminal high voltage and 1/4" spade terminals connection
White Rodgers 5059-134
Item#:
5059-134
Manufacturer Item:
5059-134
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Beckett Parts Parts 7610B0001U AquaSmart Boiler Temperature Control (120V), Gas W/ Temp. ONLY Sensor (24V Burner Circuit)
Beckett Parts 7610B0001U
Item#:
7610B0001U
Manufacturer Item:
7610B0001U
Manufacturer:
RW BECKETT CORP
Robertshaw 780U-IP10
Item#:
780U-IP10
Manufacturer Item:
780U-IP10
Manufacturer:
ROBERTSHAW CONTROLS CO.
Beckett Parts 7610A000LU Oil Aquasmart W/O Sensor 120 VAC,
,
,
Beckett Parts 7610A000LU
White Rodgers Cooling Controls 50T35-743 Circuit Board
White Rodgers 50T35-743
White Rodgers 50T35-743
White Rodgers 50T35-743
Item#:
50T35-743
Manufacturer Item:
B1809913S
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Arzel PAN-HPP03 Control Panel 3-Zone 24 VAC Heat Pump
- Residential & light commercial four zones or less
- Single or multi-stage equipment
- Variable speed Furnace Air conditioner Heat pump Dual fuel
- Independent blower & compressor staging
- Outdoor Air Temperature (OAT) sensor
- Leaving Air Temperature (LAT) sensor
- LCD display
- Zone weight percentage
- Replaceable fuse protection
- Easy to use lever style terminals
- Manual pump switch opens all dampers for testing,
,
Arzel PAN-HPP03