Brand Name
Part Type
Capacity
|◀ 37 - 48 of 75 ▶|
View:
ICM Controls Furnace Control Board, HK42FZ004/007/008/009/011/013/016/034,
,


ICM282B

Item#:
ICM282B
Manufacturer Item:
ICM282B
Manufacturer:
ICM INTERNATIONAL
ICM Controls ICM286 Furnace Control Board Replacement for Goodman PCBBF112(S), B1809926(S), 0130F00005(S),
,


ICM286

Item#:
ICM286
Manufacturer Item:
ICM286
Manufacturer:
ICM INTERNATIONAL
ICM Controls ICM2812 Furnace Control Board Replaces White Rodgers Cooling Controls 50M56U-843


ICM2812

Item#:
ICM2812
Manufacturer Item:
ICM2812
Manufacturer:
ICM INTERNATIONAL
ICM Controls ICM2901 Gas Ignition Control, 24 volt
  • Intermittent pilot gas ignition control
  • Micro-processor-based precision
  • Monitors timing, trial for ignition, rollout switch, flame sensing and lockout
  • 100% lockout safety feature
  • Works with both natural and LP gas systems
  • 0.3 amp plus valve load at 24 VAC anticipator setting
  • 85 sec trial for ignition
  • 0.5 sec flame failure response time
  • Remote flame sensing
  • Control voltage - line 24 volt (18 - 30 VAC)
  • Direct replacement for York 025-27762-700, Johnson Controls G770RJA-1
Sid Harvey Item #:ICM2901: Replaces Part #:'s : G67BG-4 | G67BG4 | G770RJA-1 | G770RJA1 | G775RJD-1C | G775RJD1C |,
,


ICM2901

Item#:
ICM2901
Manufacturer Item:
ICM2901
Manufacturer:
ICM INTERNATIONAL
White Rodgers Cooling Controls 48C21-707 2-Stage Air Handler Control 24 VAC,


48C21-707

Item#:
48C21-707
Manufacturer Item:
48C21-707
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50C51-707 2-Stage HSI Integrated Furnace Control 24 VAC,

white rodgers 50c51-707

Item#:
50C51-707
Manufacturer Item:
50C51-707
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56-743 Hot Surface Igniter Nitride Integrated Furnace Control, 25 VAC, 0.45 amp, 50/60 Hz
  • System diagnostic LED with fault recall
  • Multi speed circulator
  • 1 or 2-stage gas valve
  • Relay load ratings - 1.5 amp at 25 VAC 50/60 Hz 0.6 pico-F valve relay, 6 amp at 120 VAC 50/60 Hz (resistive) igniter relay, 2.2 amp full load, 3.5 amp locked rotor at 120 VAC inducer relay, 14.5 amp full load, 25 amp locked rotor at 120 VAC circulator relay
  • Flame current requirements - 1 micro-amp DC minimum current to insure flame detection, 0.10 micro-amp DC maximum current for non-detection, 100 mega-ohm maximum allowable leakage resistance
  • 0.8 sec flame establishing time, 2 sec flame failure response time
,

50M56-743

Item#:
50M56-743
Manufacturer Item:
50M56-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
ICM Controls ICM283 Hot Surface Universal Gas Ignition Control Module for Gas-Fired Furnaces, Boilers and Other Heating Applications, 120 and 24 VAC
  • Low cost, direct replacement ignition control
  • Single/dual rod sensing capabilities
  • Switch selectable lockout times, ignition trials
  • Works with both Natural and LP gas systems
  • Diagnostic LED to aid in troubleshooting
Sid Harvey Item #:ICM283: Replaces Part #:'s : H5780,
,


ICM283

Item#:
ICM283
Manufacturer Item:
ICM283
Manufacturer:
ICM INTERNATIONAL
Taco is a hydro air fan control is an interface between the thermostat and air handler. It also has an isolated end switch to start the boiler and/or pump. When the thermostat calls for heat, the fan control energizes the end switch relay and allows the fan to operate at low speed when the water is above the optional aquastat setting. When the thermostat calls for cooling, the fan control energizes the condenser and operates on high speed.
  • External indicator lights
  • Works with 1 or 2-speed air handlers
  • 100% factory tested
  • Automatic multi-speed switching
  • Snap-in PC board
  • Prevents false calls for fan operation
  • Simplified wiring
  • Universal thermostat compatibility
  • Contractor friendly PC board layout
  • Increased operating efficiency
  • Extended 3 years warranty
  • Built-in time delays
  • Separate contacts for pump and boiler
  • Pump exercise timer
  • Additional aquastat connection for freeze protection
,
,


HAFC-201

Item#:
HAFC-201
Manufacturer Item:
HAFC201-4
Manufacturer:
TACO INC.
ICM Controls ICM291 Ignition Module Pre-Purge: 45 seconds Trial for Ignition: 5+2 seconds,
,


ICM291

Item#:
ICM291
Manufacturer Item:
ICM291
Manufacturer:
ICM INTERNATIONAL
White Rodgers Cooling Controls 21D83M-843 1-Stage Integrated Furnace Control Circuit Board Kit, 25 VAC, 0.45 amp, 60 Hz
  • Includes diagnostic indicator flash codes
  • 3-fan speeds
  • Remote flame sensing
Sid Harvey Item #:21D83M-843: Replaces Part #:'s : 50A62-120 | 50A62-121 | 50A62-820 | 50A65-120 | 50A65-121,

21D83M-843

Item#:
21D83M-843
Manufacturer Item:
21D83M-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Resideo Y8610U Intermittent 1 or 2-Rod Natural Gas/LP Pilot Retrofit Kit for Gas-Fired Atmospheric Furnaces, 24 VAC
  • Intermittent pilot retrofit kits save energy by converting atmospheric standing pilot systems to intermittent pilot
  • Use with natural or LP gas
  • Provides 100% pilot gas shutoff if pilot fails to light, after 6 min delay, trial for ignition is repeated
  • Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed
  • 2 sec flame failure response time
  • 0 or 30 sec pre-purge time
  • Ignition sequence - continuous retry, after trial for ignition, pilot gas shuts off for 5 min then another trial for pilot ignition takes place
  • Typical gas control - VR8204, VR8304
  • Ignition source - internal high voltage spark generator
  • Ignition trials to lockout - continuous retry
  • 1 amp pilot, 2 amp at 24 VAC maximum valve load
  • Q345, Q3451 typical ignition hardware
  • 15 or 90 sec lockout timing and ignition trial time
  • VR8204, VR8304 typical gas control
Sid Harvey Item #:Y8610U4001: Replaces Part #:'s : MHY8610U4001,
,


Y8610U4001

Item#:
Y8610U4001
Manufacturer Item:
Y8610U4001
Manufacturer:
HONEYWELL
|◀ 37 - 48 of 75 ▶|
View: