Brand Name
Type
Inlet Size
Outlet Size
Pressure Setting
|◀ 217 - 228 of 252 ▶|
View:
Watts Water B911S Bronze Combination Fill Valve Feeder and Backflow Preventer, 1/2" Sweat
  • Pre-assembled for ease of installation
  • Easy service accessibility
  • High capacity fill valve for quick system filling and purging
  • All bronze body construction union solder x NPT connections
  • Installed on the boiler feed line to provide make-up water to the boiler
  • The valve shall contain a watts regulator model 9D backflow preventer and model 1156 feed water pressure regulator
Sid Harvey Item #:B911S: Replaces Part #:'s : 2K412,
,

Watts Water B911S

Item#:
B911S
Manufacturer Item:
0386462
Manufacturer:
WATTS REGULATOR CO
Watts Water B911 Bronze Combination Fill Valve Feeder and Backflow Preventer, 1/2" Threaded
  • Pre-assembled for ease of installation
  • Easy service accessibility
  • High capacity fill valve for quick system filling and purging
  • All bronze body construction union NPT x NPT connections
  • Installed on the boiler feed line to provide make-up water to the boiler
  • The valve shall contain a watts regulator model 9D backflow preventer and model 1156 feed water pressure regulator
,
,

Watts Water B911T

Item#:
B911T
Manufacturer Item:
0386463
Manufacturer:
WATTS REGULATOR CO
Resideo Braukmann DS06 Dial Set Pressure Regulating Valve is a high quality pressure regulating valve that maintains a constant outlet pressure over a wide range of inlet supply pressures. It is suitable for potable water and irrigation applications. The downstream pressure adjustment dial eliminates the need for a pressure gauge when adjusting the pressure setting (static pressure only).
  • Built-In Dial-Set- no gauge is needed to install or set static pressure
  • Built-in strainer to simplify maintenance
  • Fabric reinforced diaphragm regulator, stainless steel and engineered thermoplastics internal parts
  • Balanced single seat construction
  • Minimum pressure differential between inlet and outlet ports is 14.5 psig
  • Plus or minus 4 psig dial calibration
  • Less than 0.25% of weighted average of low lead content
  • 1/4" NPT gauge tap
  • 10:1 maximum reduction ratio
  • Double union sweat union fittings
,
,

Resideo Braukmann DS06-101-DUT-LF

Item#:
DS06-101-DUT-LF
Manufacturer Item:
DS06101DUTLF
Manufacturer:
HONEYWELL
Resideo PV100 Supervent Air Eliminator 1" FPT,
,

Honeywell PV100

Item#:
PV100
Manufacturer Item:
PV100
Manufacturer:
HONEYWELL
Resideo PV125 Supervent Air Eliminator 1-1/4" FPT,
,

Honeywell PV125

Item#:
PV125
Manufacturer Item:
PV125
Manufacturer:
HONEYWELL
The Resideo SuperVent, purges air through a no clog vent assembly, to control dirt and debris and minimize air vent fouling in Hydronic heating systems, while eliminating the need for bleeding.
  • No clog vent
  • Dirt and debris resistant
  • 360 deg adjustable collar ring for installation flexibility
  • Stainless steel concentrator which eliminates gurgling noise
  • Bronze body for rigid construction
Sid Harvey Item #:PV150: Replaces Part #:'s : R55-621,
,

Honeywell PV150

Item#:
PV150
Manufacturer Item:
PV150
Manufacturer:
HONEYWELL
Resideo PV125S Supervent Air Eliminator 1-1/4" OD,
,

Honeywell PV125S

Item#:
PV125S
Manufacturer Item:
PV125S
Manufacturer:
HONEYWELL
Resideo PV100S Supervent Air Eliminator 1" OD,
,

Honeywell PV100S

Item#:
PV100S
Manufacturer Item:
PV100S
Manufacturer:
HONEYWELL
Spirotherm Spirovent Junior Microbubble VJP Series Solid Brass Air,
,

Spirotherm VJP100TM

Item#:
VJP100TM
Manufacturer Item:
VJP100TM
Manufacturer:
SPIROTHERM INC
Spirotherm Spirovent Junior Microbubble VJP Series Solid Brass Air,
,

Spirotherm VJP125TM

Item#:
VJP125TM
Manufacturer Item:
VJP125TM
Manufacturer:
SPIROTHERM INC
Noisy pipes, valves, and other air-related noises are often accepted as the signs of a functioning system. Excessive pump noise, cavitation, and cascading in terminal units are considered normal. But air in system water can cause corrosion, reduced efficiency, poorly heated or inadequately cooled rooms, accelerated component wear and on-going complaints. There is a device that will keep your system free of air permanently. Less maintenance, quiet operation, fewer costs!. Unlike conventional air eliminators or air scoops, the Spirovent completely eliminates 100% of the free air, 100% of the entrained air, and up to 99.6% of the dissolved air in the system. Consisting of woven copper wire soldered to a copper tube, the patented Spirotube creates a low velocity area in the Spirovent that scrubs the bubbles from the water. The air bubbles rise and collect in the air chamber before they are vented from the system via an integral automatic valve. Air problems become a thing of the past.
  • Maintenance free
  • No venting required
  • Vent head is designed to stay dry, dirt and leak resistant
  • 1/2" male thread port for pressure testing or remote venting of unwanted gases
  • Quiet operation
  • Increased component life
  • Reduced oxygen based corrosion and pump cavitation
  • The automatic air vent is guaranteed not to leak and can only be closed by the installer for a pressure test
  • The air chamber has been designed so that dirt cannot reach the valve
  • Large capacity collection chamber reduces the need for frequent draining
  • Drain valve for flushing out the dirt
  • Brass vent head
  • Non-ferrous float
  • ViTon seal and o-ring
  • Copper coalescing medium

    Spirotherm VJS100TM

Item#:
VJS100TM
Manufacturer Item:
VJS100TM
Manufacturer:
SPIROTHERM INC
Noisy pipes, valves, and other air-related noises are often accepted as the signs of a functioning system. Excessive pump noise, cavitation, and cascading in terminal units are considered normal. But air in system water can cause corrosion, reduced efficiency, poorly heated or inadequately cooled rooms, accelerated component wear and on-going complaints. There is a device that will keep your system free of air permanently. Less maintenance, quiet operation, fewer costs!. Unlike conventional air eliminators or air scoops, the Spirovent completely eliminates 100% of the free air, 100% of the entrained air, and up to 99.6% of the dissolved air in the system. Consisting of woven copper wire soldered to a copper tube, the patented Spirotube creates a low velocity area in the Spirovent that scrubs the bubbles from the water. The air bubbles rise and collect in the air chamber before they are vented from the system via an integral automatic valve. Air problems become a thing of the past.
  • Maintenance free
  • No venting required
  • Vent head is designed to stay dry, dirt and leak resistant
  • 1/2" male thread port for pressure testing or remote venting of unwanted gases
  • Quiet operation
  • Increased component life
  • Reduced oxygen based corrosion and pump cavitation
  • The automatic air vent is guaranteed not to leak and can only be closed by the installer for a pressure test
  • The air chamber has been designed so that dirt cannot reach the valve
  • Large capacity collection chamber reduces the need for frequent draining
  • Drain valve for flushing out the dirt
  • Brass vent head
  • Non-ferrous float
  • ViTon seal and o-ring
  • Copper coalescing medium
Sid Harvey Item #:VJR150TM: Replaces Part #:'s : L38-346,
,

Spirotherm VJR150TM

Item#:
VJR150TM
Manufacturer Item:
VJR150TM
Manufacturer:
SPIROTHERM INC
|◀ 217 - 228 of 252 ▶|