Brand Name
Part Type
Inlet Size
Outlet Size
Connection Type
Pressure Range
Capillary Length
|◀ 25 - 36 of 43 ▶|
View:
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
  • 180 PSI
  • 1/2" OD
,

LAC-4-180-1/2OD

,

LAC-4-180-1/2OD

Item#:
LAC-4-180-1/2OD
Manufacturer Item:
903038P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
  • 210 PSI
  • 1/2" OD
,

LAC-5-210-1/2OD

,

LAC-5-210-1/2OD

Item#:
LAC-5-210-1/2OD
Manufacturer Item:
903071P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
  • 295 PSI
  • 1/2" OD
,

LAC-4-295HP-1/2OD

,

LAC-4-295HP-1/2OD

Item#:
LAC-4-295HP-1/2OD
Manufacturer Item:
903111P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
The ORD valve is a pressure differential valve that responds to changes in the pressure difference across the valve, Figure 6 on the next page. The valve designation stands for Opens on Rise of Differential pressure. Therefore, the ORD is dependent on some other control valve or action for its operation. And in this respect, it is used with the ORI for head pressure control. As the ORI valve starts to throttle the flow of liquid refrigerant from the condenser, a pressure differential is created across the ORD. When the differential reaches setpoint, the ORD starts to open and bypasses hot gas to the liquid drain line. As the differential increases, the ORD opens further until its full stroke is reached at a differential of 10 psi above setpoint. Due to its function in the control of head pressure, the full stroke can be utilized in selecting the ORD. The standard pressure setting for the ORD is 20 psig. For systems where the pressure drop between the compressor and the receiver is higher than 14 psi, an ORD with a higher setting is available.
  • 20 PSI
    • 5/8" OD

      ORD-4-20

Item#:
ORD-4-20
Manufacturer Item:
902877
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
  • 100 PSI
  • 3/8" OD
,

LAC-4-100-3/8OD

,

LAC-4-100-3/8OD

Item#:
LAC-4-100-3/8OD
Manufacturer Item:
903017P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
  • 180 PSI
  • 3/8" OD
,

LAC-4-180-3/8OD

,

LAC-4-180-3/8OD

Item#:
LAC-4-180-3/8OD
Manufacturer Item:
903024P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
  • 210 PSI
  • 3/8" OD

,

LAC-4-210-3S

,

LAC-4-210-3S

Item#:
LAC-4-210-3S
Manufacturer Item:
903005P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
  • 100 PSI
  • 5/8" OD
,

LAC-5-100-5/8OD

,

LAC-5-100-5/8OD

Item#:
LAC-5-100-5/8OD
Manufacturer Item:
903050P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
  • 180 PSI
  • 5/8" OD
,

LAC-5-180-5/8OD

,

LAC-5-180-5/8OD

Item#:
LAC-5-180-5/8OD
Manufacturer Item:
903029P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker OROA, open on rise of outlet, is a non-adjustable head pressure control valve which performs the function of limiting the flow of liquid refrigerant from the condenser and at the same time regulates the flow of hot gas around the condenser to the receiver.
  • Highest quality components
  • Durable and reliable
  • Precision engineering
  • Adjustable settings
  • Practical and economical
  • Easy to install
  • Tested for accuracy
  • 5/8" OD
  • 180 PSI
,

OROA-5-180-5/8

,

OROA-5-180-5/8

Item#:
OROA-5-180-5/8
Manufacturer Item:
902919P
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker OROA-5-180-7/8 Head Pressure Control Valve 7/8" OD 180 psi Provides Pressure Control

OROA-5-180-7/8

Item#:
OROA-5-180-7/8
Manufacturer Item:
902926P
Manufacturer:
NEUCO, INC
Parker 903406P Hot Gas Bypass Valve 1/2" 0/80,

903406P

,

903406P

Item#:
903406P
Manufacturer Item:
ADRSE-2-0/80-1/2
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
|◀ 25 - 36 of 43 ▶|
View: