Brand Name
Connection Size
Refrigerant
Capacity
Length
Width
Height
|◀ 13 - 24 of 25 ▶|
View:
Refrigeration Research 1918 Liquid Receiver 5" x 10" 6 Pounds,
,



1918


1918

Item#:
1918
Manufacturer Item:
1918
Manufacturer:
REFRIGERATION RESEARCH INC
Refrigeration Research 1921 Liquid Receiver Tank Assembly 4" x 10" 4 LBS,
,



1921


1921

Item#:
1921
Manufacturer Item:
1921
Manufacturer:
REFRIGERATION RESEARCH INC
Refrigeration Research 1911 Liquid Receiver 6" x 12" 10 Pounds 3/8" Flare x 3/8" Flare,
,



Refrigeration Research 1911


Refrigeration Research 1911

Item#:
1911
Manufacturer Item:
1911
Manufacturer:
REFRIGERATION RESEARCH INC
Refrigeration Research 3738 Suction Accumulator 7/8" Vertical,
,



Refrigeration Research 3738


Refrigeration Research 3738

Item#:
3738
Manufacturer Item:
3738
Manufacturer:
REFRIGERATION RESEARCH INC
Refrigeration Research 3706 Suction Accumulator 1-3/8" Vertical,
,



3706


3706

Item#:
3706
Manufacturer Item:
3706
Manufacturer:
REFRIGERATION RESEARCH INC
Refrigeration Research 3703 Suction Accumulator 3/4" Vertical,
,



3703


3703

Item#:
3703
Manufacturer Item:
3703
Manufacturer:
REFRIGERATION RESEARCH INC
Refrigeration Research 3702 Suction Accumulator 5/8" Vertical,
,



3702


3702

Item#:
3702
Manufacturer Item:
3702
Manufacturer:
REFRIGERATION RESEARCH INC
Refrigeration Research 3212 Liquid Receiver Tank Assembly 6" x 8" 16 LBS,

,



Refrigeration Research 3212


Refrigeration Research 3212

Item#:
3212
Manufacturer Item:
3212
Manufacturer:
REFRIGERATION RESEARCH INC
Air conditioning, heat pump, truck refrigeration and many other applications require intermittent operation of the refrigeration compressor. Especially in remote applications, the suction line may trap or hold quantities of liquid which are suddenly dumped into the compressor as it starts up. This is frequently the cause of broken valves, pisTons, broken or bent connecting rods, blown gaskets and bearing washout. Proper installation of the Refrigeration Research suction accumulator in the suction line, just before the compressor, eliminates damage. If correctly sized, relatively large quantities of liquid refrigerant may return through the suction line and the suction accumulator prevents damage to the compressor. Liquid is temporarily held in the suction accumulator and metered back to the compressor along with any oil, at a controlled rate, through the metering orifice. Therefore, damage to the compressor is prevented and the compressor immediately and quietly goes to work.
    ,
    ,



    Refrigeration Research 3700-01


    Refrigeration Research 3700-01

    Item#:
    3700-01
    Manufacturer Item:
    3700-01
    Manufacturer:
    REFRIGERATION RESEARCH INC
    Refrigeration Research 5315 Refrigeration Receiver, 6 lb Capacity, 3/8" SAE Inlet x 3/8" SAE Valve Outlet, 10" L x 5" Diameter
    • Refrigeration research receivers have been made continuously for over 50 years
    • They are used widely by original equipment manufacturers throughout the industry
    • They are backed by a reputation for quality and service
    • These receivers with valves and fittings attached are hydrogen brazed for cleanliness and pressure tested for reliability
    • 430 deg F fusible plug is installed on all receivers except #2030, #2039, and #9028
    • All valves are supplied with steel stem caps with copper gaskets and brass flare nuts and caps, all receivers are powder coated for excellent corrosion resistance
    • Pressure tested for 500 psi maximum working pressure
    ,
    ,



    5315 6 LB RECEIVER


    5315 6 LB RECEIVER

    Item#:
    5315 6 LB RECEIVER
    Manufacturer Item:
    5315
    Manufacturer:
    REFRIGERATION RESEARCH INC
    Henry Technologies S-5585 Oil Separator 5/8" OD



    S-5585


    S-5585

    Item#:
    S-5585
    Manufacturer Item:
    S-5585
    Manufacturer:
    HENRY TECHNOLOGIES, INC
    White Rodgers Cooling Controls AOFD is designed specifically for refrigerant systems that use POE oil.The AOFD protects compressors by removing moisture and trapping contaminants.Oil Filter Drier, 3/8", Male Flare
    • Designed to clean and dry POE oil
    • 3/8" male flare connections for easy replacement
    • 3 micron filtration for optimum oil cleaning
    • Large filter surface area to provide maximum filtration
    • Contains desiccant for moisture removal
    • Designed to operate at a very low pressure drop
    • Dual access valves for pressure drop monitoring
    ,



    AOFD553


    AOFD553

    Item#:
    AOFD553
    Manufacturer Item:
    AOFD553
    Manufacturer:
    WHITE-RODGERS COOLING CONTROLS
    |◀ 13 - 24 of 25 ▶|
    View: