Brand Name
Type
|◀ 13 - 23 of 23 ▶|
View:
Sid Harvey High Limit Aquastat Relay 8F differential REMANUFACTURED. Immersion type controllers that combine high limit protection with switchingrelay control of burner and circulator motors
    High limit opens burner circuit only.
  • Includes transformer and accessory terminals for adding a remote low limit controller.
  • Case available for horizontal or vertical mounting.
  • Requires a 24 VAC thermostat with heat anticipator set at 0.2 amps.
Item#:
C312-8R
Manufacturer Item:
L8148A1017
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290-1R Bronze Close On Rise Aquastat, 100 - 240 deg F, Remanufactured
  • 3" insulation, stop factory set at 240 deg F, well adapter and heat conductive compound includes,
Item#:
C290-1R
Manufacturer Item:
L4006B1155-1163
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C312-10R High Limit Aquastat Relay, 100 - 240 deg F1>
Item#:
C312-10R
Manufacturer Item:
C312-10
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C434-9R Fan Limit Control, Remanufactured
  • ,
Item#:
C434-9R
Manufacturer Item:
C434-9
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
  • Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
  • High limit opens burner circuit only
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • 1-1/2 - 3 Inch depth less well insulation
  • Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
  • Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential,
Item#:
C312-9R
Manufacturer Item:
L8148J1009
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-7R Fan limit Control 5'' REMANUFACTURED,
Item#:
C434-7R
Manufacturer Item:
C434-7R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C293-3R Aquastat Immersion SPDT 100-240 Degrees REMANUFACTURED,
Item#:
C293-3R
Manufacturer Item:
L6006A1145
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124A High and Low Limit Circulator Triple Aquastat Relay, 120 VAC, 130 - 240 deg F Adjustable High Limit, 110 - 220 deg F Adjustable Low Limit
    Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-2R
Manufacturer Item:
L8124A1007,1015,1098
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-73R Heat Timer EPU-CH Blue Panel REMANUFACTURED,
Item#:
C346-73R
Manufacturer Item:
C346-73R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-72R Heat Timer EPU Blue Panel REMANUFACTURED,
Item#:
C346-72R
Manufacturer Item:
C346-72R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C346-58R Discharge Water Control, 80 - 220 deg F, 24/120/240,
Item#:
C346-70R
Manufacturer Item:
C346-70R
Manufacturer:
SID HARVEY REMANUFACTURED
|◀ 13 - 23 of 23 ▶|