|◀ 1813 - 1824 of 2246 ▶|
View:
Wayne Combustion Parts 56671-WYN1 EC-50K Repair kit

Wayne Combustion Parts 56671-WYN1

Item#:
56671-WYN1
Manufacturer Item:
56671-WYN1
Manufacturer:
WAYNE WATER SYSTEMS
Fernox 57882 F3 Cleaner,
,

Fernox 57882

Item#:
57882
Manufacturer Item:
57882
Manufacturer:
FERNOX
Item#:
62-25341-81
Flow Rate
  • Atomizing nozzles are available in a wide range of flow rates, all but eliminating the need for specially calibrated nozzles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
    Spray Angle
  • Spray angles are available from 30° through 90° in most nozzle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° nozzles. Long, narrow chambers usually require 30° to 60° spray angles.
  • Burner Air Patterns
  • Burner air patterns are much like nozzle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel nozzle. A burner with a solid air pattern will give highest efficiency with a solid cone nozzle, but the flame will probably be longer

    Bosch 7747028943

  • Item#:
    7747028943
    Manufacturer Item:
    7-747-028-943
    Manufacturer:
    BOSCH THERMOTECHNOLOGY CORP
    Flow Rate
  • Atomizing nozzles are available in a wide range of flow rates, all but eliminating the need for specially calibrated nozzles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
    Spray Angle
  • Spray angles are available from 30° through 90° in most nozzle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° nozzles. Long, narrow chambers usually require 30° to 60° spray angles.
  • Burner Air Patterns
  • Burner air patterns are much like nozzle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel nozzle. A burner with a solid air pattern will give highest efficiency with a solid cone nozzle, but the flame will probably be longer

    Bosch 7747028944

  • Item#:
    7747028944
    Manufacturer Item:
    7-747-028-944
    Manufacturer:
    BOSCH THERMOTECHNOLOGY CORP
    International Comfort Products Fast Parts NAHB00101CT Condensate Trap

    International Comfort Products Fast A/C Parts NAHB00101CT

    Item#:
    NAHB00101CT
    Manufacturer Item:
    NAHB00101CT
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    International Comfort Products Fast Parts NASA00201FS Evaporator Freeze Thermostat

    International Comfort Products Fast A/C Parts NASA00201FS

    Item#:
    NASA00201FS
    Manufacturer Item:
    NASA00201FS
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Nortek Global Heating Parts 1017207 Relay

    Nortek Global Heating Parts 1017207

    Item#:
    1017207
    Manufacturer Item:
    1017207
    Manufacturer:
    NORTEK GLOBAL (PARTS)
    Item#:
    1171481
    International Comfort Products Fast Heating Parts 1178962 Defrost Control Board

    International Comfort Products Fast Heating Parts 1178962

    Item#:
    1178962
    Manufacturer Item:
    1178962
    Manufacturer:
    ICP FAST PARTS
    International Comfort Products Fast Heating Parts 1193029 Control Board

    International Comfort Products Fast Heating Parts 1193029

    Item#:
    1193029
    Manufacturer Item:
    1193029
    Manufacturer:
    ICP FAST PARTS
    Thermo Products Parts AOPS7744 Gas Valve W/LP Kit,

    Thermo Products Heating Parts AOPS7744

    Item#:
    AOPS7744
    Manufacturer Item:
    AOPS7744
    Manufacturer:
    THERMO PRODUCTS, LLC
    |◀ 1813 - 1824 of 2246 ▶|