EWC Controls BMPLUS5000
EWC Controls BMPLUS3000 3-Zone Damper Control Panel,
,
,
EWC Controls BMPLUS3000
ICM Controls ICM102FB Adjustable Time Delay Relay, 18 - 240 VAC at 50/60 Hz, 40 milli-amp - 1.5 amp, 15 amp Inrush
,
- Delay on make
,
ICM Controls ICM102FB
Item#:
ICM102FB
Manufacturer Item:
ICM102FB
Manufacturer:
ICM INTERNATIONAL
EWC Controls NCM 300 panel provides intelligent control of Heat Pump or Conventional forced air zoning systems at a maximum of three zones using motorized dampers and practically any off-the-shelf heat/cool thermostat. With features like automatic changeover, opposite system service, short cycle timers and supply air sensing capability, the NCM 300 provides a high level of performance in a non-expandable zone control panel.
,
- 2 - 3 zones, non-expandable
- Compatible equipment - gas/electric/hydro up to 2 stages heating and 1 stage cooling and heat pump conventional up to 2 stages heating and 1 stage cooling
- Compatible thermostat: Any single stage heat/cool thermostat or 2 stage heat, 1 stage cool heat pump thermostat
- Compatible damper - EWC models URD, ND, RSD and SID, any 24 VAC 3-wire or 2-wire damper
- Staging via adjustable on-board timer (7 - 42 min)
- Enhanced hydro-air capabilities, can delay fan activation on Heating demand
- Supply air temperature monitoring to help protect HVAC equipment
- Adjustable purge time (90 or 120 sec)
- On board LED's indicate system operation
- Supply Air Sensor
,
EWC Controls NCM300
The ND Damper is constructed using Heavy Duty 0.80 extruded aluminum.
Nylon Bearings for quiet operation.
Overlapping parallel blade design insures low leakage.
Designed to operate at static pressures up to 1.5 w.c.
The UL Listed Motor Actuator is a 24 vac 3 wire power open/ power close type.
The motor actuator is rated at 18lbs. of torque. Superior to low torque Spring type motors.
The Motor Actuator housing has a NEMA1 Rating.
Integrated End-Stop Adjustment allows for a percentage of Relief Air (Leakage) to be set when the damper is
powered to closed and/or you may set a maximum open position as well.
Bright green and red LEDs Indicate damper open and closed position.
EWC Controls ND8X10
Make sure you ask for and use genuine Copleand parts. Copeland parts fit right, first time. Insisting on genuine Copeland parts will keep your refrigeration & A/C Compressor running reliably for the long haul
Copeland Parts N03036448
Arzel PAN-AB002 2-Zone Zone Control Panel
- ,
Arzel PAN-AB002
York Heating Parts S1-024-19138-001 Cube Style Relay 24 VAC 3PDT
,
,
York Heating Parts S1-023-22458-000
Item#:
S1-024-19138-001
Manufacturer Item:
S1-02419138001
Manufacturer:
YORK INTERNATIONAL- PARTS
Honeywell AT87A1106 Transformer, 48 VA, 120/208/240 VAC Primary, 24 VAC, 26.5V Open Circuit Secondary, 50/60 Hz
,
- Includes built-in protection, primary winding burnout
- Overload protection provided
,
Honeywell T394-65
Item#:
T394-65
Manufacturer Item:
AT87A1106
Manufacturer:
HONEYWELL