  • 11/2 thru 5 tons
  • Available for Environmentally Sound R410A systems
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models
  • Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left
    standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)

  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • Item#:
    FXM4X3600AL
    Manufacturer Item:
    FXM4X3600AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • 11/2 thru 5 tons
  • Available for Environmentally Sound R410A systems
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models
  • Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left
    standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)

  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied

    Browning Belt A48

  • Item#:
    FXM4X1800AL
    Manufacturer Item:
    FXM4X1800AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • 11/2 thru 5 tons
  • Available for Environmentally Sound R410A systems
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models
  • Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left
    standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)

  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • Item#:
    FVM4X6000BL
    Manufacturer Item:
    FVM4X6000BL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • 11/2 thru 5 tons
  • Available for Environmentally Sound R410A systems
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models
  • Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left
    standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)

  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • Item#:
    FVM4X3600BL
    Manufacturer Item:
    FVM4X3600BL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • 11/2 thru 5 tons
  • Available for Environmentally Sound R410A systems
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models
  • Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left
    standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)

  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • Item#:
    FVM4X2400BL
    Manufacturer Item:
    FVM4X2400BL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Multi-position design for horizontal or vertical installation without modification.
  • Standard sloped drain pans and cleanable insulation treated with an immobilized anti-microbial agent to inhibit the growth of bacteria and fungi on the insulation.
  • High-static design meets a wider range of applications than competitive packaged air handler lines.
  • Ultra Low Leak Economizer accessory provides ventilation air and free cooling with built in Fault Detection and Diagnostic (FDD) capabilities.
  • Cooling coils with mechanically bonded fins provide peak heat transfer.
  • Hot water coil, steam coil, and electric heat accessories are available.
  • Standard factory-installed thermo-static expansion valves (TXV) with removable power element on FAX/FAS units.
  • Die-formed galvanized steel casings provide durability and structural integrity. Optional paint is available.
  • Upgraded unit control board with intuitive indoor fan adjustment.
  • Standard 2-Speed Indoor Fan Motor system.
  • Item#:
    FAX120H2AA0AUA
    Manufacturer Item:
    FAX120H2AA0AUA
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Multi-position design for horizontal or vertical installation without modification.
  • Standard sloped drain pans and cleanable insulation treated with an immobilized anti-microbial agent to inhibit the growth of bacteria and fungi on the insulation.
  • High-static design meets a wider range of applications than competitive packaged air handler lines.
  • Ultra Low Leak Economizer accessory provides ventilation air and free cooling with built in Fault Detection and Diagnostic (FDD) capabilities.
  • Cooling coils with mechanically bonded fins provide peak heat transfer.
  • Hot water coil, steam coil, and electric heat accessories are available.
  • Standard factory-installed thermo-static expansion valves (TXV) with removable power element on FAX/FAS units.
  • Die-formed galvanized steel casings provide durability and structural integrity. Optional paint is available.
  • Upgraded unit control board with intuitive indoor fan adjustment.
  • Standard 2-Speed Indoor Fan Motor system.
  • Item#:
    FAX120L2AA0AUA
    Manufacturer Item:
    FAX120L2AA0AUA
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Multi-position design for horizontal or vertical installation without modification
  • Two sloped condensate pans on each unit for horizontal or vertical applications
  • Standard sloped drain pans and cleanable insulation treatedwith Environmental Protection
    Agency (EPA) registered antimicrobial agent improves indoor air quality
  • High-static design meets a wider range of applications thancompetitive packaged air handler lines
  • Ultra low leak economizer accessory provides ventilation air and free cooling with built in Fault Detection and Diagnostic (FDD) capabilities
  • Single refrigerant circuit on 072 and 091 sizes. Dual refrigerant circuit on 120-336 sizes
  • Dual circuit can be field modified for use on single circuit condensers
  • Cooling coils with mechanically bonded fins provide peak heat transfer
  • Optional 2-speed indoor fan with VFD controller
  • Standard factory-installed thermostatic expansion valve (TXV) with removable power element
  • Easy maintenance - removal of single panel allows access to virtually all components
  • Die-formed galvanized steel casings provide durability and structural integrity. Optional paint is available
  • 24-volt terminal block for control wiring connection
  • Hot water coil, steam coil, and electric heat accessories are available
  • Item#:
    FAS120HAAA2B0A
    Manufacturer Item:
    FAS120HAAA2B0A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Fujitsu FB17TSJ07NB Air Handler 1-1/2-2 Ton R410A 208/230 VAC 7 KW 17" Wide
    • ndustry Standard R-410A Refrigerant
    • Models featuring Electric Heat without Indoor CoolingCoil
    • Quiet and efficient X-13 (ECM) motor technology
    • Only 35" tall and 4-way convertible for all those tight spaces
    • Available from factory in upflow and horizontal configurations
    • Nominal airflow up to 0.5" eXternal static pressure with reduced airflow up to 1.0" eXternal static pressure
    • Factory installed MultiFleX® coils
    • Sturdy steel construction with 1" [25.4 mm] of foil faced insulation for eXcellent sound and insulating characteristics
    • Permanent, easily accessible and washable filter furnished standard
    • Circuit breaker (standard on units with more than 11 kW) meets U.L. and cUL requirements for service disconnect
    • Factory installed auXiliary electric heat provides eXact heat for indoor comfort over a variety of applications
    • Fan settings for selectable, customized cooling airflow over a wide variety of applications
    • Cabinet air leakage less than 2% at 1" H2O when tested in accordance with ASHRAE standard 193,

      FB17TSJ07NB

      ,

      FB17TSJ07NB

    Item#:
    FB17TSJ07NB
    Manufacturer Item:
    FB17TSJ07NB
    Manufacturer:
    FUJITSU
    Standard Features:
  • 240V motor, 24V controls
  • Factory installed disconnect
  • Factory or field installed electric heat
  • Separate compartment for drain connections
  • Drain pan has 3/4" male or female primary and secondary fittings
  • High efficiency cooling coil
  • Convenient equalizer connection for factory or field installed R410A TXV's (non-bleed type)
  • Easily accessible 1" filter
  • Cabinet air leakage is no more than 2% when tested in accordance with ASHRAE 193.
  • Item#:
    18UC5-R410TXV
    Manufacturer Item:
    18UC5-R410TXV
    Manufacturer:
    FIRST CO.
    International Comfort Products F5MA4X18L1AA Blower Coils Air Handlers

    F5MA4X18L1AA

    Item#:
    F5MA4X18L1AA
    Manufacturer Item:
    F5MA4X18L1AA
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Multi-position design for horizontal or vertical installation without modification
  • Two sloped condensate pans on each unit for horizontal or vertical applications
  • Standard sloped drain pans and cleanable insulation treatedwith Environmental Protection
    Agency (EPA) registered antimicrobial agent improves indoor air quality
  • High-static design meets a wider range of applications thancompetitive packaged air handler lines
  • Ultra low leak economizer accessory provides ventilation air and free cooling with built in Fault Detection and Diagnostic (FDD) capabilities
  • Single refrigerant circuit on 072 and 091 sizes. Dual refrigerant circuit on 120-336 sizes
  • Dual circuit can be field modified for use on single circuit condensers
  • Cooling coils with mechanically bonded fins provide peak heat transfer
  • Optional 2-speed indoor fan with VFD controller
  • Standard factory-installed thermostatic expansion valve (TXV) with removable power element
  • Easy maintenance - removal of single panel allows access to virtually all components
  • Die-formed galvanized steel casings provide durability and structural integrity. Optional paint is available
  • 24-volt terminal block for control wiring connection
  • Hot water coil, steam coil, and electric heat accessories are available
  • Item#:
    FAS150HAAA2AUA
    Manufacturer Item:
    FAS150HAAA2AUA
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    |◀ 25 - 36 of 183 ▶|