S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Brand Name
BTU
Voltage
Position
Fujitsu FH3617TTSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
Fujitsu FH3617TTSJSN
Item#:
FH3617TTSJSN
Manufacturer Item:
FH3617TTSJSN
Manufacturer:
FUJITSU
Fujitsu FH4821TPSASN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
- 48K BTU 4 Ton
- 208/230/1 VAC
- 21" Wide
- Multi-Position,
,
Fujitsu FH4821TTSJSN
Item#:
FH4821TTSJSN
Manufacturer Item:
FH4821TTSJSN
Manufacturer:
FUJITSU
Fujitsu FH3017TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
- 42K BTU
- 3-1/2 Ton
- 115/1 VAC
- 21" Wide
- PSC Motor
- Multi-Position,
,
Fujitsu FH4221TPSASN
Item#:
FH4221TPSASN
Manufacturer Item:
FH4221TPSASN
Manufacturer:
FUJITSU
Fujitsu FH4824TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
Fujitsu FH4824TPSJSN
Item#:
FH4824TPSJSN
Manufacturer Item:
FH4824TPSJSN
Manufacturer:
FUJITSU
Fujitsu FH6024TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
Fujitsu FH6024TPSJSN
Item#:
FH6024TPSJSN
Manufacturer Item:
FH6024TPSJSN
Manufacturer:
FUJITSU
Fujitsu FH1817TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
Fujitsu FH1817TPSJSN
Item#:
FH1817TPSJSN
Manufacturer Item:
FH1817TPSJSN
Manufacturer:
GENERAL HVAC SOLUTIONS AMERICA
Fujitsu FH3017TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
- 30K BTU 3 Ton
- 208/230/1 VAC
- 17" Wide
- PCS Motor
- Multi-Position,
,
Fujitsu FH3017TPSJSN
Item#:
FH3017TPSJSN
Manufacturer Item:
FH3017TPSJSN
Manufacturer:
FUJITSU
Fujitsu FH3017TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
- 42K BTU 3-1/2 Ton
- 208/230/1 VA
- 21" Wide
- PSC Motor
- Multi-Position,
Fujitsu FH4221TPSJSN
Item#:
FH4221TPSJSN
Manufacturer Item:
FH4221TPSJSN
Manufacturer:
FUJITSU
standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)
International Comfort Products FXM4X4800AL
Item#:
FXM4X4800AL
Manufacturer Item:
FXM4X4800AL
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
Baked-On Powder Coated Hydronic Air Handler with TXV Metering
- Multi function micro-processor circuit board
- Blower start relay - eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
- Manual air vent on hot water coil
- Blower door shut-off switch
- Slide out hot water coil for easier service
- 2-speed fan operation
- Convertible horizontal drain pan
- PisTon type metering device (standard)
- Copper tube heating and cooling coils
- Compatible with all major brands of split condensing units and heat pumps
- Primary and secondary condensate drain connections
- Factory installed filter drier
- 1" filter easily accessible
- Without pump
First Company 60HBXB-HW-R410A-TXV
Item#:
60HBXB-HW-R410A-TXV
Manufacturer Item:
60HBXB-HW-R410A-TXV
Manufacturer:
FIRST CO.
STANDARD SPECIFICATIONS
Rifled copper tubing, enhanced aluminum fins.
Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
Left- or right-hand refrigerant and plumbing connections.
Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
Externally mounted flowrater body with Schrader valve for hiss-testing.
Heavy duty plastic drain pans on most models.
Upflow without field modification. Downflow applications require plate kit, included.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for use with both R-22 and R-410a when proper metering device is used.
Ten-year limited warranty.
Aspen CC60A24-245L-059
Item#:
CC60A24-245L-059
Manufacturer Item:
CC60A24-245L-059
Manufacturer:
ASPEN MFG. LLC
STANDARD SPECIFICATIONS
Rifled copper tubing, enhanced aluminum fins.
Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
Left- or right-hand refrigerant and plumbing connections.
Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
Externally mounted flowrater body with Schrader valve for hiss-testing.
Heavy duty plastic drain pans on most models.
Upflow without field modification. Downflow applications require plate kit, included.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for use with both R-22 and R-410a when proper metering device is used.
Ten-year limited warranty.
Aspen CC30A24-145L-059
Item#:
CC30A24-145L-059
Manufacturer Item:
CC30A24-145L-059
Manufacturer:
ASPEN MFG. LLC