S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Multi-function micro-processor circuit board with these standard features:
Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air
handler
Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after
thermostat is satisfied, for increased efficiency
120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied
motorized zone valves
Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
Manual Air Vent on hot water coil
Blower door shut-off switch (except 60/61HCXW (PSC))
Slide out hot water coil for easier service
Copper tube heating and cooling coils
Compatible with all major brands of split condensing units and heat pumps
Attractive baked-on powder coated cabinet
Primary and secondary condensate drain connections
Easily accessible 1 filter
Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
24HCXW2V10AVB00AAF
Item#:
24HCXW2V10AVB00AAF
Manufacturer Item:
6024W2V10AVB00AAF
Manufacturer:
FIRST CO.
Multi-function micro-processor circuit board with these standard features:
Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air
handler
Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after
thermostat is satisfied, for increased efficiency
120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied
motorized zone valves
Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
Manual Air Vent on hot water coil
Blower door shut-off switch (except 60/61HCXW (PSC))
Slide out hot water coil for easier service
Copper tube heating and cooling coils
Compatible with all major brands of split condensing units and heat pumps
Attractive baked-on powder coated cabinet
Primary and secondary condensate drain connections
Easily accessible 1 filter
Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
24HCXW2010AVB00AAF
Item#:
24HCXW2010AVB00AAF
Manufacturer Item:
6024W2010AVB00AAF
Manufacturer:
FIRST CO.
Multi-function micro-processor circuit board with these standard features:
Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air
handler
Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after
thermostat is satisfied, for increased efficiency
120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied
motorized zone valves
Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
Manual Air Vent on hot water coil
Blower door shut-off switch (except 60/61HCXW (PSC))
Slide out hot water coil for easier service
Copper tube heating and cooling coils
Compatible with all major brands of split condensing units and heat pumps
Attractive baked-on powder coated cabinet
Primary and secondary condensate drain connections
Easily accessible 1 filter
Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
First Company 30HCXW2010AVB00AAF
Item#:
30HCXW2010AVB00AAF
Manufacturer Item:
6030W2010AVB00AAF
Manufacturer:
FIRST CO.
Multi-function micro-processor circuit board with these standard features:
Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air
handler
Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after
thermostat is satisfied, for increased efficiency
120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied
motorized zone valves
Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
Manual Air Vent on hot water coil
Blower door shut-off switch (except 60/61HCXW (PSC))
Slide out hot water coil for easier service
Copper tube heating and cooling coils
Compatible with all major brands of split condensing units and heat pumps
Attractive baked-on powder coated cabinet
Primary and secondary condensate drain connections
Easily accessible 1 filter
Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
36HCXW2010AVB00AAF
Item#:
36HCXW2010AVB00AAF
Manufacturer Item:
6036W2010AVB00AAF
Manufacturer:
FIRST CO.
Baked-On Powder Coated Hydronic Air Handler with TXV Metering
- Multi function micro-processor circuit board
- Blower start relay - eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
- Manual air vent on hot water coil
- Blower door shut-off switch
- Slide out hot water coil for easier service
- 2-speed fan operation
- Convertible horizontal drain pan
- PisTon type metering device (standard)
- Copper tube heating and cooling coils
- Compatible with all major brands of split condensing units and heat pumps
- Primary and secondary condensate drain connections
- Factory installed filter drier
- 1" filter easily accessible
- Without pump
First Company 48HCXB-HW-TXV410
Item#:
48HCXB-HW-TXV410
Manufacturer Item:
48HCXB-HW-TXV410
Manufacturer:
FIRST CO.
Baked-On Powder Coated Hydronic Air Handler with TXV Metering
- Multi function micro-processor circuit board
- Blower start relay - eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
- Manual air vent on hot water coil
- Blower door shut-off switch
- Slide out hot water coil for easier service
- 2-speed fan operation
- Convertible horizontal drain pan
- PisTon type metering device (standard)
- Copper tube heating and cooling coils
- Compatible with all major brands of split condensing units and heat pumps
- Primary and secondary condensate drain connections
- Factory installed filter drier
- 1" filter easily accessible
- Without pump
First Company 60HCXB-HW-R410A-TXV
Item#:
60HCXB-HW-R410A-TXV
Manufacturer Item:
6060H3HW4X
Manufacturer:
FIRST CO.
STANDARD Features
3-way airflow (except 60/61HCX)
Factory installed horizontal drain pan
Completely prewired with 0-25kW electric heat (except 0kW models)
Compatible with major brands of split condensing units and heat pumps (Contact factory for correct match with outdoor unit)
Piston-type metering device or factory or field installed TXV (non-bleed type) on cooling coil
Factory installed filter
Attractive baked on finish
Copper tube cooling coils
Primary and secondary drain connections on cooling coil
Fully insulated and painted galvanized steel cabinet
Factory installed disconnect switch (over 10kW models)
First Company 60HCXW3010BVB00AAF
Item#:
60HCXW3010BVB00AAF
Manufacturer Item:
6060W3010BVB00AAF
Manufacturer:
FIRST CO.
STANDARD SPECIFICATIONS
Rifled copper tubing, enhanced aluminum fins.
Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
Left- or right-hand refrigerant and plumbing connections.
Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
Externally mounted flowrater body with Schrader valve for hiss-testing.
Heavy duty plastic drain pans on most models.
Upflow without field modification. Downflow applications require plate kit, included.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for use with both R-22 and R-410a when proper metering device is used.
Ten-year limited warranty.
Aspen CC24A2G-145L-059
Item#:
CC24A2G-145L-059
Manufacturer Item:
CC24A2G-145L-059
Manufacturer:
ASPEN MFG. LLC
APPLICATION VERSATILITY
Standard Upflow without field modification. Downflow applications require field kit, sold separately.
A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
AHRI certifiable with all brands of A/C and heat pump systems.
Features
Rifled copper tubing, enhanced aluminum fins.
Heavy duty plastic drain pans on most models.
Embossed galvanized cabinets standard. Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.
Aspen CC30A34-145L-189
Item#:
CC30A34-145L-189
Manufacturer Item:
CC30A34-145L-189
Manufacturer:
ASPEN MFG. LLC
APPLICATION VERSATILITY
Standard Upflow without field modification. Downflow applications require field kit, sold separately.
A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
AHRI certifiable with all brands of A/C and heat pump systems.
Features
Rifled copper tubing, enhanced aluminum fins.
Heavy duty plastic drain pans on most models.
Embossed galvanized cabinets standard. Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.
Aspen CC24A34-145L-189
Item#:
CC24A34-145L-189
Manufacturer Item:
CC24A34-145L-189
Manufacturer:
ASPEN MFG. LLC
STANDARD SPECIFICATIONS
Rifled copper tubing, enhanced aluminum fins.
Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
Left- or right-hand refrigerant and plumbing connections.
Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
Externally mounted flowrater body with Schrader valve for hiss-testing.
Heavy duty plastic drain pans on most models.
Upflow without field modification. Downflow applications require plate kit, included.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for use with both R-22 and R-410a when proper metering device is used.
Ten-year limited warranty.
Aspen CC36A2G-175L-059
Item#:
CC36A2G-175L-059
Manufacturer Item:
CC36A2G-175L-059
Manufacturer:
ASPEN MFG. LLC
STANDARD SPECIFICATIONS
Rifled copper tubing, enhanced aluminum fins.
Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
Left- or right-hand refrigerant and plumbing connections.
Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
Externally mounted flowrater body with Schrader valve for hiss-testing.
Heavy duty plastic drain pans on most models.
Upflow without field modification. Downflow applications require plate kit, included.
AHRI certifiable with all brands of A/C and heat pump systems.
ETL listed for use with both R-22 and R-410a when proper metering device is used.
Ten-year limited warranty.
Aspen CC42AG-210L-059
Item#:
CC42AG-210L-059
Manufacturer Item:
CC42A2G-210L-059
Manufacturer:
ASPEN MFG. LLC