|◀ 1621 - 1632 of 1739 ▶|
View:
Multi-function micro-processor circuit board with these standard features:
  • Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
  • Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
  • Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after thermostat is satisfied, for increased efficiency
  • 120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied motorized zone valves
  • Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
  • Manual Air Vent on hot water coil
  • Blower door shut-off switch (except 60/61HCXW (PSC))
  • Slide out hot water coil for easier service
  • Copper tube heating and cooling coils
  • Compatible with all major brands of split condensing units and heat pumps
  • Attractive baked-on powder coated cabinet
  • Primary and secondary condensate drain connections
  • Easily accessible 1 filter
  • Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193

    24HCXW2V10AVB00AAF

  • Item#:
    24HCXW2V10AVB00AAF
    Manufacturer Item:
    6024W2V10AVB00AAF
    Manufacturer:
    FIRST CO.
    Multi-function micro-processor circuit board with these standard features:
  • Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
  • Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
  • Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after thermostat is satisfied, for increased efficiency
  • 120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied motorized zone valves
  • Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
  • Manual Air Vent on hot water coil
  • Blower door shut-off switch (except 60/61HCXW (PSC))
  • Slide out hot water coil for easier service
  • Copper tube heating and cooling coils
  • Compatible with all major brands of split condensing units and heat pumps
  • Attractive baked-on powder coated cabinet
  • Primary and secondary condensate drain connections
  • Easily accessible 1 filter
  • Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193

    24HCXW2010AVB00AAF

  • Item#:
    24HCXW2010AVB00AAF
    Manufacturer Item:
    6024W2010AVB00AAF
    Manufacturer:
    FIRST CO.
    Multi-function micro-processor circuit board with these standard features:
  • Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
  • Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
  • Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after thermostat is satisfied, for increased efficiency
  • 120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied motorized zone valves
  • Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
  • Manual Air Vent on hot water coil
  • Blower door shut-off switch (except 60/61HCXW (PSC))
  • Slide out hot water coil for easier service
  • Copper tube heating and cooling coils
  • Compatible with all major brands of split condensing units and heat pumps
  • Attractive baked-on powder coated cabinet
  • Primary and secondary condensate drain connections
  • Easily accessible 1 filter
  • Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193

    First Company 30HCXW2010AVB00AAF

  • Item#:
    30HCXW2010AVB00AAF
    Manufacturer Item:
    6030W2010AVB00AAF
    Manufacturer:
    FIRST CO.
    Multi-function micro-processor circuit board with these standard features:
  • Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
  • Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
  • Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after thermostat is satisfied, for increased efficiency
  • 120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied motorized zone valves
  • Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
  • Manual Air Vent on hot water coil
  • Blower door shut-off switch (except 60/61HCXW (PSC))
  • Slide out hot water coil for easier service
  • Copper tube heating and cooling coils
  • Compatible with all major brands of split condensing units and heat pumps
  • Attractive baked-on powder coated cabinet
  • Primary and secondary condensate drain connections
  • Easily accessible 1 filter
  • Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193

    36HCXW2010AVB00AAF

  • Item#:
    36HCXW2010AVB00AAF
    Manufacturer Item:
    6036W2010AVB00AAF
    Manufacturer:
    FIRST CO.
    Baked-On Powder Coated Hydronic Air Handler with TXV Metering
    • Multi function micro-processor circuit board
    • Blower start relay - eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
    • Manual air vent on hot water coil
    • Blower door shut-off switch
    • Slide out hot water coil for easier service
    • 2-speed fan operation
    • Convertible horizontal drain pan
    • PisTon type metering device (standard)
    • Copper tube heating and cooling coils
    • Compatible with all major brands of split condensing units and heat pumps
    • Primary and secondary condensate drain connections
    • Factory installed filter drier
    • 1" filter easily accessible
    • Without pump

      First Company 48HCXB-HW-TXV410

    Item#:
    48HCXB-HW-TXV410
    Manufacturer Item:
    48HCXB-HW-TXV410
    Manufacturer:
    FIRST CO.
    Baked-On Powder Coated Hydronic Air Handler with TXV Metering
    • Multi function micro-processor circuit board
    • Blower start relay - eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
    • Manual air vent on hot water coil
    • Blower door shut-off switch
    • Slide out hot water coil for easier service
    • 2-speed fan operation
    • Convertible horizontal drain pan
    • PisTon type metering device (standard)
    • Copper tube heating and cooling coils
    • Compatible with all major brands of split condensing units and heat pumps
    • Primary and secondary condensate drain connections
    • Factory installed filter drier
    • 1" filter easily accessible
    • Without pump

      First Company 60HCXB-HW-R410A-TXV

    Item#:
    60HCXB-HW-R410A-TXV
    Manufacturer Item:
    6060H3HW4X
    Manufacturer:
    FIRST CO.
    STANDARD Features
  • 3-way airflow (except 60/61HCX)
  • Factory installed horizontal drain pan
  • Completely prewired with 0-25kW electric heat (except 0kW models)
  • Compatible with major brands of split condensing units and heat pumps (Contact factory for correct match with outdoor unit)
  • Piston-type metering device or factory or field installed TXV (non-bleed type) on cooling coil
  • Factory installed filter
  • Attractive baked on finish
  • Copper tube cooling coils
  • Primary and secondary drain connections on cooling coil
  • Fully insulated and painted galvanized steel cabinet
  • Factory installed disconnect switch (over 10kW models)

    First Company 60HCXW3010BVB00AAF

  • Item#:
    60HCXW3010BVB00AAF
    Manufacturer Item:
    6060W3010BVB00AAF
    Manufacturer:
    FIRST CO.
    STANDARD SPECIFICATIONS
  • Rifled copper tubing, enhanced aluminum fins.
  • Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
  • Left- or right-hand refrigerant and plumbing connections.
  • Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
  • Externally mounted flowrater body with Schrader valve for hiss-testing.
  • Heavy duty plastic drain pans on most models.
  • Upflow without field modification. Downflow applications require plate kit, included.
  • AHRI certifiable with all brands of A/C and heat pump systems.
  • ETL listed for use with both R-22 and R-410a when proper metering device is used.
  • Ten-year limited warranty.

    Aspen CC24A2G-145L-059

  • Item#:
    CC24A2G-145L-059
    Manufacturer Item:
    CC24A2G-145L-059
    Manufacturer:
    ASPEN MFG. LLC
    APPLICATION VERSATILITY
  • Standard Upflow without field modification. Downflow applications require field kit, sold separately.
  • A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
  • ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
  • AHRI certifiable with all brands of A/C and heat pump systems. Features
  • Rifled copper tubing, enhanced aluminum fins.
  • Heavy duty plastic drain pans on most models.
  • Embossed galvanized cabinets standard. Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.

    Aspen CC30A34-145L-189

  • Item#:
    CC30A34-145L-189
    Manufacturer Item:
    CC30A34-145L-189
    Manufacturer:
    ASPEN MFG. LLC
    APPLICATION VERSATILITY
  • Standard Upflow without field modification. Downflow applications require field kit, sold separately.
  • A2L refrigerants require a Refrigerant Detection System (RDS) for compliance.
  • ETL listed for R22 and 410A. ETL listed for R454B and R32 with Refrigerant Detection System (RDS).
  • AHRI certifiable with all brands of A/C and heat pump systems. Features
  • Rifled copper tubing, enhanced aluminum fins.
  • Heavy duty plastic drain pans on most models.
  • Embossed galvanized cabinets standard. Fully insulated cabinets with faced insulation. Split access doors in front of cabinet for easy service access.

    Aspen CC24A34-145L-189

  • Item#:
    CC24A34-145L-189
    Manufacturer Item:
    CC24A34-145L-189
    Manufacturer:
    ASPEN MFG. LLC
    STANDARD SPECIFICATIONS
  • Rifled copper tubing, enhanced aluminum fins.
  • Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
  • Left- or right-hand refrigerant and plumbing connections.
  • Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
  • Externally mounted flowrater body with Schrader valve for hiss-testing.
  • Heavy duty plastic drain pans on most models.
  • Upflow without field modification. Downflow applications require plate kit, included.
  • AHRI certifiable with all brands of A/C and heat pump systems.
  • ETL listed for use with both R-22 and R-410a when proper metering device is used.
  • Ten-year limited warranty.

    Aspen CC36A2G-175L-059

  • Item#:
    CC36A2G-175L-059
    Manufacturer Item:
    CC36A2G-175L-059
    Manufacturer:
    ASPEN MFG. LLC
    STANDARD SPECIFICATIONS
  • Rifled copper tubing, enhanced aluminum fins.
  • Immersion-tested at 500 psi, then nitrogen-pressurized and sealed.
  • Left- or right-hand refrigerant and plumbing connections.
  • Liquid line - 3/8 ODS, suction line - 3/4 ODS on 1-1/2- 3 ton & 7/8 ODS on 3-1/2 - 5 ton.
  • Externally mounted flowrater body with Schrader valve for hiss-testing.
  • Heavy duty plastic drain pans on most models.
  • Upflow without field modification. Downflow applications require plate kit, included.
  • AHRI certifiable with all brands of A/C and heat pump systems.
  • ETL listed for use with both R-22 and R-410a when proper metering device is used.
  • Ten-year limited warranty.

    Aspen CC42AG-210L-059

  • Item#:
    CC42AG-210L-059
    Manufacturer Item:
    CC42A2G-210L-059
    Manufacturer:
    ASPEN MFG. LLC
    |◀ 1621 - 1632 of 1739 ▶|
    View: