S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Brand Name
Type
Length
Width
Voltage
Hart & Cooley 013220 Golden Sand Enamel Steel Round Butterfly Damper, 6"
Hart & Cooley HC126
Item#:
HC126
Manufacturer Item:
013220
Manufacturer:
HART & COOLEY, LLC.
Starting with the development of the first zoning dampers and registers in the 1950s to today, with exclusive Plug & Play dampers Zonefirst has led the way in excellence and continued innovation.
ZONEFIRST is the first company that successfully developed and marketed HVAC Zoning Systems back in the 1950s and is today a leading manufacturer of HVAC zone dampers and zoning systems. Several other major zoning companies are in business due to ZONEFIRST.
It was in the mid to late 1950s when Richard Foster developed the first automatic motorized dampers, registers and difusers that were thermostatically controlled. He marketed these products under the trade name Zone-A-Trol with another company when in 1964 he founded Trolex Corporation and the start of the well known trade name Trol-A-Temp. In 1999 the Trol-A-Temp brand was acquired by Honeywell.
Since that time, Trolex has continued to manufacture zone dampers for a number of OEMs. In 2004 Trolex re-entered the HVAC market as ZONE-A-TROL and later the ZONEFIRST tradename. This new name signifies the many firsts the company has developed in the HVAC industry. We were the first company to develop automatic dampers, registers, and diffusers for zoning, centralized zone controllers, the first zoning system to feature normally open dampers and the first to zone heat pumps in the early 1970s
ZONEFIRST is the first company that successfully developed and marketed HVAC Zoning Systems back in the 1950s and is today a leading manufacturer of HVAC zone dampers and zoning systems. Several other major zoning companies are in business due to ZONEFIRST.
It was in the mid to late 1950s when Richard Foster developed the first automatic motorized dampers, registers and difusers that were thermostatically controlled. He marketed these products under the trade name Zone-A-Trol with another company when in 1964 he founded Trolex Corporation and the start of the well known trade name Trol-A-Temp. In 1999 the Trol-A-Temp brand was acquired by Honeywell.
Since that time, Trolex has continued to manufacture zone dampers for a number of OEMs. In 2004 Trolex re-entered the HVAC market as ZONE-A-TROL and later the ZONEFIRST tradename. This new name signifies the many firsts the company has developed in the HVAC industry. We were the first company to develop automatic dampers, registers, and diffusers for zoning, centralized zone controllers, the first zoning system to feature normally open dampers and the first to zone heat pumps in the early 1970s
Zone First H32K
RectorSeal 81965 Metal Ceiling Support Rough-In-Flange, 16" L x 12" W x 3/8" H
RectorSeal L02004
Item#:
L02004
Manufacturer Item:
81965
Manufacturer:
RECTORSEAL - HOUSTON
EWC CONTROLS INC NCM-3Z
Item#:
NCM-3Z
Manufacturer Item:
NCM-3Z
Manufacturer:
EWC CONTROLS INC
The ND Damper is constructed using Heavy Duty 0.80 extruded aluminum.
Nylon Bearings for quiet operation.
Overlapping parallel blade design insures low leakage.
Designed to operate at static pressures up to 1.5 w.c.
The UL Listed Motor Actuator is a 24 vac 3 wire power open/ power close type.
The motor actuator is rated at 18lbs. of torque. Superior to low torque Spring type motors.
The Motor Actuator housing has a NEMA1 Rating.
Integrated End-Stop Adjustment allows for a percentage of Relief Air (Leakage) to be set when the damper is
powered to closed and/or you may set a maximum open position as well.
Bright green and red LEDs Indicate damper open and closed position.
EWC Controls ND-12X18
Item#:
ND-12X18
Manufacturer Item:
ND12X18
Manufacturer:
EWC CONTROLS INC
SPECIFICATIONS:
INPUT VOLTAGE: 19-30VAC 60 Hz
Transformer 40-60VA MAX. NEC Class 2.
CURRENT DRAW: Max 14VA @ 24VAC.
OVER-CURRENT PROTECTION: 2.5 amp or 60 VA.
WIRING: 18 gauge Solid copper wire. Do not use Stranded or Shielded Cable.
TEMPERATURE: -20° to 160°F (-29° to 71°C).
HUMIDITY: 0% - 95% RH Non-Condensing. 10.0
EWC CONTROLS INC NCM300L
The ND Damper is constructed using Heavy Duty 0.80 extruded aluminum.
Nylon Bearings for quiet operation.
Overlapping parallel blade design insures low leakage.
Designed to operate at static pressures up to 1.5 w.c.
The UL Listed Motor Actuator is a 24 vac 3 wire power open/ power close type.
The motor actuator is rated at 18lbs. of torque. Superior to low torque Spring type motors.
The Motor Actuator housing has a NEMA1 Rating.
Integrated End-Stop Adjustment allows for a percentage of Relief Air (Leakage) to be set when the damper is
powered to closed and/or you may set a maximum open position as well.
Bright green and red LEDs Indicate damper open and closed position.
EWC Controls ND-14X8
Item#:
ND-14X8
Manufacturer Item:
ND14X8
Manufacturer:
EWC CONTROLS INC
All products are designed and manufactured for use within forced air systems, providing effective distribution of conditioned air from the air handler to every room of a residence.Metal duct and fittings are constructed from hot-dipped Galvanized steel. All metal products are made true to gauge. Sheet metal duct, pipe, and fittings are designed with industry and regional standards in mind, as well as ACCA and SMACNA recommendations and requirements. Products are hand-crafted to reduce noise and friction and constructed to maximize efficiency by increasing airflow without leaks. The quality of our Galvanized steel allows us to create fittings that are rust-resistant and durable
