Brand Name
Type
Voltage
Pressure
|◀ 37 - 48 of 204 ▶|
View:
Head Gasket Domestic
,
McDonnell & Miller CO-12

McDonnell & Miller CO-12

Item#:
CO-12
Manufacturer Item:
302600
Manufacturer:
XYLEM INC.
CycleGard Electronic Low Water Cut-Off 120 VAC 15 psi Automatic
    Burner circuit contacts open after 15 sec delay in a low water condition
  • Automatically reactivates burner circuit 30 sec after water reaches the probe, allowing optional water feeder to raise water level above the probe
  • Intermittent level test (ILT) feature provides maximum boiler protection by removing power from the burner circuit at set intervals
  • NEMA 1 enclosure

    Hydrolevel CG4501560

Item#:
CG4501560
Manufacturer Item:
45-460-1560
Manufacturer:
HYDROLEVEL COMPANY
Hydrolevel CycleGard CG400-2090 Probe Style ElectronicLow Water Cut-Off, 24 VAC, 15 psi, Automatic Reset
    Intermittent level test - maximum protection for foaming boilers
  • 15 sec burner off delay
  • 30 sec burner on delay
  • Low water indicating light
  • Direct boiler mounting - eliminates blowdowns

    Hydrolevel CG400-2090

Item#:
CG400-2090
Manufacturer Item:
45-410-2090
Manufacturer:
HYDROLEVEL COMPANY
Honeywell L4081B1096/U High Limit Circulator Aquastat Control, 110 - 220 deg F Low, 130 - 240 deg F High
    An immersion type liquid-filled sensing element actuates (2) snap switches
  • (1) switch operates as a high limit control
  • The other switch operates as a low limit and/or circulator control, depending on the model
  • Controller may be mounted in any positioning and needs no leveling
  • Separate, easy-to-read, calibrated dial and setpoint adjustments for each switch
  • Differential adjustment on low limit or circulator switch on select models
  • All adjustments accessible inside front cover
  • Push-in terminals for quick connecting
  • 1-sensing element for easy installation
  • (2) SPST snap switches act independently at respective temperature settings
  • 3" insulation depth
  • 360 VA transformer load ignition electrical ratings
  • High limit, low limit and/or circulator controllers used to regulate boiler water temperature in gas- or oil-fired hydronic heating systems

    Honeywell C322-4A

Item#:
C322-4A
Manufacturer Item:
L4081B1096
Manufacturer:
HONEYWELL
Honeywell L8124E1016 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
    Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: 1.25 amp at 24 VAC; 30 VA (total load) terminals B1-B2 and TV-Z
  • Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC

    Honeywell C317-7

Item#:
C317-7
Manufacturer Item:
L8124E1016
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
  • Totally enclosed micro switch snap-acting switches operate on temperature rise to setpoint
  • Visible control point scale and external adjustments screw permit easy setting
  • Horizontal or vertical insertion of the sensing element
  • Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications
  • Direct or well immersion of the sensing element
  • Includes heat-conductive compound, well adapter Honeywell L4006E1067 High Limit Manual Reset Aquastat, 130 - 270 deg F, 10 - 25 deg F Differential

    Honeywell C290-6

Item#:
C290-6
Manufacturer Item:
L4006E1067
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
    Totally enclosed micro switch snap-acting switch
  • Visible control point scale and external adjustments screw permit easy setting
  • Available horizontal or vertical mounting of the remote element into boiler, tank or other container
  • Remote temperature sensing element detects and responds rapidly to temperature changes
  • Case mounts to a vertical surface
  • Includes 66" length capillary tubing, stop factory set at 240 F

    Honeywell C293-4

Item#:
C293-4
Manufacturer Item:
L6008A1192
Manufacturer:
HONEYWELL
Honeywell C293-3 Aquastat Immersion High or Low Limit SPDT 110-240 Degrees,
Honeywell C293-3

Honeywell C293-3

Item#:
C293-3
Manufacturer Item:
L6006A1145
Manufacturer:
HONEYWELL
Honeywell C320-15 Dual Aquastat High Limit/Low Limit or Pump

Nordic Technology FAST-STAT5000

Item#:
C320-15
Manufacturer Item:
L4081A1023
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
    Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
  • Visible control point scale and external adjustments screw permit easy setting
  • Horizontal or vertical insertion of the sensing element
  • Direct/well immersion of the sensing element
  • Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications
  • Contacts break on temperature rise
  • Screw terminals wiring

    Honeywell C290-6A

Item#:
C290-6A
Manufacturer Item:
L4006E1091
Manufacturer:
HONEYWELL
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST

    Honeywell C317-8

Item#:
C317-8
Manufacturer Item:
L8124G1020
Manufacturer:
HONEYWELL
Honeywell L8124A1015 Triple Aquastat Relay, 120 VAC
    Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
  • Includes 3" insertion well and ground screw

    Honeywell C317-2B

Item#:
C317-2B
Manufacturer Item:
L8124A1015
Manufacturer:
HONEYWELL
|◀ 37 - 48 of 204 ▶|
View: