Brand Name
Voltage
Lockout Time
Ignition Type
|◀ 13 - 24 of 39 ▶|
View:
Oilco OC-10 CAD Cell Eye for Oil Primary Controls
Item#:
R80-100
Manufacturer Item:
OC-10
Manufacturer:
OILCO COMPANY
Honeywell Protectorelay R8184M1051 Oil Burner Control for Boilers, 120 - 240 VAC
    Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
  • Intermittent ignition is on while the burner is on
  • Solid state flame sensing circuit
  • External button to manually reset safety switch after lockout
  • Enclosed safety switch must be manually reset after safety shutdown
  • R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
Item#:
R75-58
Manufacturer Item:
R8184M1051
Manufacturer:
HONEYWELL
Carlin Parts 40200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
    Interrupted duty ignition
  • 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
  • Recycle on flame failure
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
Item#:
R77-10
Manufacturer Item:
40200-02S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 6020002S015120 CAD Cell Oil Primary Control, 15 sec Trial
    Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • Valve delay on/motor delay off (pre/post-purge)
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
Item#:
R77-44
Manufacturer Item:
6020002S015120
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts Combustion Technology, Inc. the industrys technological leader in oil and gas, residential and commercial burners, controls and igniters.
    Interrupted duty ignition for high efficiency
  • SMC technology for safety monitoring
  • LED indicators, alarm contacts and pump prime for economic as well as efficient performance
  • Serviceman reset protection ( latch-up after three consecutive lockouts)
  • 15 sec trial for ignition (TFI) other timings available
  • It offers recycle on flame failure and 1.3 sec flame failure response time
  • Oil primary control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 9 VA
  • It has a temperature rating of 32 - 140 deg F, resistive rating of 1500 ohm and safety switch timing of 15 sec
  • Primary control offers serviceman reset protection and valve delay on/motor delay off feature
  • It has a motor load of 10 FLA/60 LRA, ignitor load of 120 VAC at 60 Hz and valve load of 120 VAC at 60 Hz
  • 500 VA motor load
  • 24 VAC/VDC, 2 amp alarm contacts
  • Flame signal test jack
Sid Harvey Item #:R77-41: Replaces Part #:'s : 7G998,
carlin parts r77-41
Item#:
R77-41
Manufacturer Item:
6020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 50200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
    Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
Item#:
R77-40
Manufacturer Item:
5020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Resideo R7284U1004 Oil Burner Primary Control 15/30/45 Second Lockout Timing
Item#:
R7284U1004
Manufacturer Item:
R7284U1004
Manufacturer:
HONEYWELL
Sid Harvey 70064 Pre-Assembled Flame Detector Kit
    Includes E-style mounting bracket, Beckett cad cell eye, 30 Inch leads
Item#:
R82-4
Manufacturer Item:
70064
Manufacturer:
MITCO MFG.
Sid Harvey R82-2 Cadium Sulfide Flame Detector Kit, 60"Lead f/ A, E, J, & P Type
    For sequencing oil burner systems use with protectorelay oil primary controls such as R4166, R4184, R8182, R8184, and R8404.
  • 2-piece model cell plug ins.
  • Includes: 4 different style mounting brackets oil line bracket, cad cell eye, 60" leads
Item#:
R82-2
Manufacturer Item:
C554A1463
Manufacturer:
MITCO MFG.
Honeywell 120320 Cad Cell Eye for Use with Oil Primary Control in Burner
Item#:
R82-1
Manufacturer Item:
120320/U
Manufacturer:
HONEYWELL
Riello 20132573 Cad Cell Eye for Use with Oil Primary Control
Item#:
20132573
Manufacturer Item:
20132573
Manufacturer:
RIELLO CORP OF AMERICA
Riello 20010004 Primary Control for R40 F3-F5-F10-F15-F20, BF3, BF5 Oil Burners with Manual and 530SE/C24V Hydraulic Air Shutter
Item#:
20010004
Manufacturer Item:
20010004
Manufacturer:
RIELLO CORP OF AMERICA
|◀ 13 - 24 of 39 ▶|
View: