|◀ 61 - 72 of 1423 ▶|
View:
Garber R Epoxy Coated Spin On Filter Gar-Ber Fits 1A-10GBK,
,



Delavan 87-1

Item#:
R
Manufacturer Item:
2605
Manufacturer:
GENERAL FILTERS INC.
General Filters Cartridge W/Bio Gasket



General Filters RBG

Item#:
RBG
Manufacturer Item:
2606
Manufacturer:
GENERAL FILTERS INC.
Suntec A2YA-7916 1-Stage Oil Pump, 7 gph Strainer and 7 gph at 100 psi, 3 gph at 200 psi Rated Nozzle, 3450 RPM, 10 psi Inlet and Return
  • Right hand nozzle port location
  • Has a unique circuit that exhibits a dependable cut-off, a high 1-pipe lift capacity and automatic 2-pipe purging
  • The pump circuit contains a positive displacement involute gear set and two controlling valves
  • Fuel oil #2 and lighter, not compatible for use with blends higher than 5% biodiesel
  • 1-pipe system (2-pipe system possible)
  • Diaphragm cut-off
  • Pressure regulation valve function
  • 5/16" diameter shaft
Sid Harvey Item #:P4-101: Replaces Part #:'s : P4-101R,
,



Suntec P4-10

Item#:
P4-101
Manufacturer Item:
A2YA7916
Manufacturer:
SUNTEC INDUSTRIES INC
Tuthill P99-5 Oil Pump Tuthill 60 GPH,
,



Suntec P4-83

Item#:
P99-5
Manufacturer Item:
OOLE
Manufacturer:
F.T. THOMAS PUMP & SUPPLY
General Filters 9013 Microfiber Replacement Cartridge, 10 micron
Sid Harvey Item #:RF-2: Replaces Part #:'s : L37-524,

,



General Filters R2000

Item#:
RF-2
Manufacturer Item:
RF-2
Manufacturer:
GAR-BER FUEL FILTERS
Item#:
RF-4
Item#:
R7284B1024
Honeywell Protectorelay R8184G4066/U Non-Recycle Oil Burner Control with Safety Timing, 4-1/8" W x 4-3/8" H x 2-1/2" Depth
  • Provides automatic, non-recycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with External reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 volts thermostat required
  • 15 second safety timing, alarm outputs, and manual safety switch
  • Intermittent ignition timing
Sid Harvey Item #:R75-37: Replaces Part #:'s : R75-37R,
,



Carlin Parts R77-41

Item#:
R75-37
Manufacturer Item:
R8184G4066
Manufacturer:
HONEYWELL
Carlin Parts 48245S Intermittent Duty Oil Burner Primary Control, 120 VAC
  • 45 sec trial for ignition
  • Red LED lockout indicator
  • Thermostat/aquastat compatible SMC (safety monitoring circuit) technology
  • 5 amp full load, 60 amp locked rotor motor load
  • 120 VAC, 60 Hz, 500 VA igniter load
Sid Harvey Item #:R75-47: Replaces Part #:'s : 7G193,

,



Carlin Parts R75-45

Item#:
R75-47
Manufacturer Item:
48245S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Honeywell Protectorelay R8184G4082 Oil Burner Control
  • With 45 sec safety timing and alarm outputs
  • Provides automatic, nonrecycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • Enclosed safety switch with External reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)
Sid Harvey Item #:R75-44: Replaces Part #:'s : L40-026,
,



honeywell r75-44

Item#:
R75-44
Manufacturer Item:
R8184G4082
Manufacturer:
HONEYWELL
Item#:
R75-45
Item#:
R75-40
|◀ 61 - 72 of 1423 ▶|