S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Garber R Epoxy Coated Spin On Filter Gar-Ber Fits 1A-10GBK,
,
,
gar-ber r
gar-ber r
Item#:
R
Manufacturer Item:
2605
Manufacturer:
GENERAL FILTERS INC.
General Filters Cartridge W/Bio Gasket
RBG
RBG
Item#:
RBG
Manufacturer Item:
2606
Manufacturer:
GENERAL FILTERS INC.
Tuthill P99-5 Oil Pump Tuthill 60 GPH,
,
,
P99-5
P99-5
General Filters R2000 Epoxy Coated Spin On Filter
R2000
R2000
Resideo R7284B1024 Oil Burner Primary Control 15 Second Lockout Timing Interrupted Ignition,
,
,
Resideo R7284B1024
Resideo R7284B1024
Honeywell C554A1794 Cadmium-Sulfide Flame Detector for Oil Fired Burner
,
- With 60 Inch lead
- Photoconductive flame sensing device for sequencing oil burner systems
- On flame failure, the light sensitive cadmium sulfide cell, in conjunction with flame sensing circuitry, causes the protectorelay control to shutdown the main oil burner
- Glass-to-metal hermetic seal in plug-in cell prevents deterioration by humidity, soot or oil fumes
- Replaceable 130367 cad cell
- Includes type E mounting bracket and fuel line adaptor
- Used with R4166, R4184, R8182, R8184, R8185, R8404, R8991, R7997, R7184, R7284
- Minimum sensitivity at 2 feet candles
,
Honeywell R82
Honeywell R82
Item#:
R82
Manufacturer Item:
C554A1794
Manufacturer:
MITCO MFG.
Honeywell Protectorelay R8184G4066/U Non-Recycle Oil Burner Control with Safety Timing, 4-1/8" W x 4-3/8" H x 2-1/2" Depth
,
- Provides automatic, non-recycling control of an intermittent ignition oil burner system
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
- C554A cadmium sulfide flame detector and 24 volts thermostat required
- 15 second safety timing, alarm outputs, and manual safety switch
- Intermittent ignition timing
,
honeywell r75-37
honeywell r75-37
Carlin Parts 48245S Intermittent Duty Oil Burner Primary Control, 120 VAC
,
- 45 sec trial for ignition
- Red LED lockout indicator
- Thermostat/aquastat compatible SMC (safety monitoring circuit) technology
- 5 amp full load, 60 amp locked rotor motor load
- 120 VAC, 60 Hz, 500 VA igniter load
,
carlin parts r75-47
carlin parts r75-47
Item#:
R75-47
Manufacturer Item:
48245S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Honeywell Protectorelay R8184G4082 Oil Burner Control
,
- With 45 sec safety timing and alarm outputs
- Provides automatic, nonrecycling control of an intermittent ignition oil burner system
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)
,
R75-44
R75-44
Carlin Parts 42230-02S CAD Cell Oil Primary Control for Thermostat/Aquastat Compatible, 120 VAC, 500 watt
,
- Interrupted duty ignition for high efficiency
- SMC technology for safety monitoring
- Diagnostic LED indicators
- Secondary burner control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 10 VA from limit circuit
- 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
- 30 sec trial for Ignition 42230 (1.3 sec flame failure response time (FFRT)
- Recycle on flame failure
- It has a temperature rating of 32 - 140 deg F and resistive rating of 1500 ohm
- Valve delay on/motor delay off for economic as well as efficient performance
- It has a motor load of 10 FLA/60 LRA and ignitor load of 120 VAC at 60 Hz
- 500 VA motor load
,
carlin parts r75-45
carlin parts r75-45
Item#:
R75-45
Manufacturer Item:
4223002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 volt
,
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 15 sec safety timing, alarm outputs and manual safety switch
,
honeywell r75-40
honeywell r75-40
Item#:
R75-40
Manufacturer Item:
R8184G4009
Manufacturer:
HONEYWELL
Oilco OC-10 CAD Cell Eye for Oil Primary Controls
,
,
oilco r80-100
oilco r80-100
Item#:
R80-100
Manufacturer Item:
OC-10
Manufacturer:
OILCO COMPANY